X-ray irradiation of silicon detectors

被引:0
|
作者
Chmill, V. [1 ]
机构
[1] Royal Inst Technol, AlbaNova, Dept Phys, SE-10691 Stockholm, Sweden
关键词
X-ray; silicon; detector; radiation hardness; voltage training;
D O I
10.1016/j.nima.2006.07.057
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon pad detectors were irradiated with a 30 kVp X-ray energy spectrum and the change in capacity and dark current was measured as a function of radiation dose and restoring time. After irradiation of the detectors the parameters were monitored and the time to get back to the baseline before irradiation was measured. The relaxation process of the detector functionality (the recovery of the characteristics) was observed with bias voltage applied to the detectors. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:722 / 726
页数:5
相关论文
共 50 条
  • [21] X-ray detectors: Amorphous silicon offers digital promise
    Graeve, T
    PHOTONICS SPECTRA, 1998, 32 (01) : 115 - 116
  • [22] Temporal response of silicon EUV and soft X-ray detectors
    Artyomov, A. P.
    Baksht, E. H.
    Tarasenko, V. F.
    Fedunin, A. V.
    Chaikovsky, S. A.
    Aruev, P. N.
    Zabrodskii, V. V.
    Petrenko, M. V.
    Sobolev, N. A.
    Suhanov, V. L.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2015, 58 (01) : 102 - 106
  • [23] Silicon Detectors with a Differential Discriminatorfor Use in X-Ray Diffractometers
    Osadchii, S. M.
    Petukhov, A. A.
    Dunin, V. B.
    JOURNAL OF SURFACE INVESTIGATION, 2019, 13 (04): : 690 - 694
  • [24] Monolithic active-matrix silicon X-ray detectors
    Carini, Gabriella A.
    Chen, Wei
    Li, Zheng
    Rehak, Pavel
    Siddons, D. Peter
    Patel, Jyotica
    Steen, Steven E.
    Haensch, Wilfred
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C162 - C162
  • [25] A new generation of X-ray detectors based on silicon carbide
    Bertuccio, G
    Casiraghi, R
    Cetronio, A
    Lanzieri, C
    Nava, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 433 - 435
  • [26] Temporal response of silicon EUV and soft X-ray detectors
    A. P. Artyomov
    E. H. Baksht
    V. F. Tarasenko
    A. V. Fedunin
    S. A. Chaikovsky
    P. N. Aruev
    V. V. Zabrodskii
    M. V. Petrenko
    N. A. Sobolev
    V. L. Suhanov
    Instruments and Experimental Techniques, 2015, 58 : 102 - 106
  • [27] Application of silicon strip detectors to X-ray computed tomography
    Yoshida, S
    Ohsugi, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 541 (1-2): : 412 - 420
  • [28] Silicon Detectors with a Differential Discriminatorfor Use in X-Ray Diffractometers
    S. M. Osadchii
    A. A. Petukhov
    V. B. Dunin
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2019, 13 : 690 - 694
  • [29] XEUS - the X-ray mirrors and X-ray detectors
    Willingale, R
    X-RAY ASTRONOMY 2000, 2001, 234 : 589 - 596
  • [30] Epitaxial GaAs X-ray detectors for X-ray astrophysics
    Bavdaz, M
    Owens, A
    Peacock, A
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 : 451 - 456