Magnetic Resonance Imaging Diffusion Tensor Tractography: Evaluation of Anatomic Accuracy of Different Fiber Tracking Software Packages

被引:73
|
作者
Feigl, Guenther C. [1 ]
Hiergeist, Wolfgang [1 ]
Fellner, Claudia [2 ]
Schebesch, Karl-Michael M. [1 ]
Doenitz, Christian [1 ]
Finkenzeller, Thomas [2 ]
Brawanski, Alexander [1 ]
Schlaier, Juergen [1 ]
机构
[1] Univ Hosp Regensburg, Dept Neurosurg, Regensburg, Germany
[2] Univ Hosp Regensburg, Inst Radiol, Regensburg, Germany
关键词
Anatomic accuracy; Brain mapping; DTI; Navigation; Surgery; BRAIN; RESECTION; VALIDATION; SCLEROSIS; PATHWAYS; LOBE;
D O I
10.1016/j.wneu.2013.01.004
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Diffusion tensor imaging (DTI)-based tractography has become an integral part of preoperative diagnostic imaging in many neurosurgical centers, and other nonsurgical specialties depend increasingly on DTI tractography as a diagnostic tool. The aim of this study was to analyze the anatomic accuracy of visualized white matter fiber pathways using different, readily available DTI tractography software programs. METHODS: Magnetic resonance imaging scans of the head of 20 healthy volunteers were acquired using a Siemens Symphony TIM 1.5T scanner and a 12-channel head array coil. The standard settings of the scans in this study were 12 diffusion directions and 5-mmslices. The fornices were chosen as an anatomic structure for the comparative fiber tracking. Identical data sets were loaded into nine different fiber tracking packages that used different algorithms. The nine software packages and algorithms used were NeuroQLab (modified tensor deflection [TEND] algorithm), Sorensen DTI task card (modified streamline tracking technique algorithm), Siemens DTI module (modified fourth-order Runge-Kutta algorithm), six different software packages from Trackvis (interpolated streamline algorithm, modified FACT algorithm, second-order Runge-Kutta algorithm, Qball [FACTalgorithm], tensorline algorithm, Q-ball [second-order Runge-Kutta algorithm]), DTI Query (modified streamline tracking technique algorithm), Medinria (modified TEND algorithm), Brainvoyager (modified TEND algorithm), DTI Studio modified FACTalgorithm, and the BrainLab DTI module based on the modified Runge-Kutta algorithm. Three examiners (a neuroradiologist, a magnetic resonance imaging physicist, and a neurosurgeon) served as examiners. Theywere double-blindedwith respect to the test subject and the fiber tracking software used in the presented images. Each examiner evaluated 301 images. The examiners were instructed to evaluate screenshots from the different programs based on twomain criteria: (i) anatomic accuracy of the course of the displayed fibers and (ii) number of fibers displayed outside the anatomic boundaries. RESULTS: The mean overall grade for anatomic accuracy was 2.2 (range, 1.1-3.6) with a standard deviation (SD) of 0.9. The mean overall grade for incorrectly displayed fibers was 2.5 (range, 1.6-3.5) with a SD of 0.6. The mean grade of the overall program ranking was 2.3 with a SD of 0.6. The overall mean grade of the program ranked number one (NeuroQLab) was 1.7 (range, 1.5-2.8). The mean overall grade of the program ranked last (BrainLab iPlan Cranial 2.6 DTI Module) was 3.3 (range, 1.7-4). The difference between the mean grades of these two programs was statistically highly significant (P < 0.0001). There was no statistically significant difference between the programs ranked 1-3: NeuroQLab, Srensen DTI Task Card, and Siemens DTI module. CONCLUSIONS: The results of this study show that there is a statistically significant difference in the anatomic accuracy of the tested DTI fiber tracking programs. Although incorrectly displayed fibers could lead to wrong conclusions in the neurosciences field, which relies heavily on this noninvasive imaging technique, incorrectly displayed fibers in neurosurgery could lead to surgical decisions potentially harmful for the patient if used without intraoperative cortical stimulation. DTI fiber tracking presents a valuable noninvasive preoperative imaging tool, which requires further validation after important standardization of the acquisition and processing techniques currently available.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 50 条
  • [21] Diffusion Tensor Magnetic Resonance Imaging and Fiber Tractography of the Sacral Plexus in Children with Spina Bifida EDITORIAL COMMENT
    Mitchell, Michael
    JOURNAL OF UROLOGY, 2014, 192 (03): : 933 - 933
  • [22] Optimization of the Parameters for Diffusion Tensor Magnetic Resonance Imaging Data Acquisition for Breast Fiber Tractography at 1.5 T
    Wang, Yuan
    Zhang, Xiao-Peng
    Li, Yan-Ling
    Li, Xiao-Ting
    Hu, Yan
    Cui, Yong
    Sun, Ying-Shi
    Zhang, Xiao-Yan
    CLINICAL BREAST CANCER, 2014, 14 (01) : 61 - 67
  • [23] Topography of the human corpus callosum revisited - Comprehensive fiber tractography using diffusion tensor magnetic resonance imaging
    Hofer, Sabine
    Frahm, Jens
    NEUROIMAGE, 2006, 32 (03) : 989 - 994
  • [24] Diffusion tensor imaging and fiber tractography in movement disorders
    Saxena, M.
    Kumaran, S. S.
    Goyal, V.
    Behari, M.
    MOVEMENT DISORDERS, 2012, 27 : S253 - S254
  • [25] Diffusion tensor imaging and fiber tractography in acute stroke
    Mukherjee, P
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2005, 15 (03) : 655 - +
  • [26] Diffusion tensor imaging and fiber tractography in brain malformations
    Poretti, Andrea
    Meoded, Avner
    Rossi, Andrea
    Raybaud, Charles
    Huisman, Thierry A. G. M.
    PEDIATRIC RADIOLOGY, 2013, 43 (01) : 28 - 54
  • [27] Diffusion tensor imaging and fiber tractography in brain malformations
    Andrea Poretti
    Avner Meoded
    Andrea Rossi
    Charles Raybaud
    Thierry A. G. M. Huisman
    Pediatric Radiology, 2013, 43 : 28 - 54
  • [28] Diffusion tensor imaging and fiber tractography of the normal epididymis
    Bougia, Christina K.
    Astrakas, Loukas
    Pappa, Ourania
    Maliakas, Vasileios
    Sofikitis, Nikolaos
    Argyropoulou, Maria I.
    Tsili, Athina C.
    ABDOMINAL RADIOLOGY, 2024, 49 (08) : 2932 - 2941
  • [29] Diffusion Tensor Magnetic Resonance Imaging and Fiber Tracking of Trigeminal Nerves in Relapsing Herpetic Keratouveitis
    Labetoulle, M.
    Nasser, G.
    De Monchy, I.
    Gendron, G.
    Pogorzalek, N.
    Ducreux, D.
    Benoudiba, F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)