Line switching for alleviating overloads under line outage condition taking bus voltage limits into account

被引:18
|
作者
Arya, LD [1 ]
Choube, SC [1 ]
Kothari, DP [1 ]
机构
[1] SGSITS, Dept Elect Engn, Indore 452003, India
关键词
line switching; distribution factors; contingency analysis; security enhancement; network anlaysis;
D O I
10.1016/S0142-0615(99)00044-7
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an interactive line switching algorithm for overload alleviation under line outage condition. Line outage distribution factors are used to determine line flows. It has the advantage that a contingency from a base case can be computed for an actual flow on a Line in a real time situation. A relation has been derived for calculating load bus voltages under post-contingency condition and after Line switching. In the event of bus voltage limit violation the algorithm explores the possibility of the other line to be switched. The algorithm also investigates the possibility of overload rotation amongst two disjoint sets of overloaded lines obtained after Line switching, if overload elimination is not possible. The algorithm has been tested on the IEEE 25 bus system. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 35 条
  • [31] Observation and analysis of positive leader re-illumination in a 10 m ultra-high voltage transmission line gap under switching impulse voltages
    黄标
    周旋
    王涉
    庄池杰
    曾嵘
    邓乐
    Plasma Science and Technology, 2024, 26 (10) : 98 - 105
  • [32] Observation and analysis of positive leader re-illumination in a 10 m ultra-high voltage transmission line gap under switching impulse voltages
    Huang, Biao
    Zhou, Xuan
    Wang, She
    Zhang, Chijie
    Zeng, Rong
    Deng, Le
    PLASMA SCIENCE & TECHNOLOGY, 2024, 26 (10)
  • [33] LINE SPECTRUM EMISSION ON A SURFACE AND SWITCHING CHARACTERISTICS OF (NI0.4ZN0.6)FE2O4 FERRITE UNDER PULSE VOLTAGE
    MORIMOTO, J
    USUI, K
    KASHIWABARA, S
    MIYAKAWA, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1982, 21 (09): : 1380 - 1381
  • [34] Discharge Characteristics of 252kV Gas Insulated Transmission Line under Switching Impulse Voltage in C4F7N/CO2 Mixtures
    Zheng Z.
    Chen N.
    Li Z.
    Li Q.
    Ding W.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2021, 36 (14): : 3055 - 3062
  • [35] <bold>Movement of Metallic Particles in Gas Insulated Line Using </bold>SF6 and N2 Gas Mixture under the Influence of Power Frequency and Switching Transient Voltage
    Upadhyay, Poonam
    Amernath, J.
    Singh, B. P.
    Upadhyay, Pravin
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 280 - 283