A fractographic study of clinically retrieved zirconia-ceramic and metal-ceramic fixed dental prostheses

被引:83
|
作者
Pang, Zhen [1 ]
Chughtai, Asima [1 ]
Sailer, Irena [2 ]
Zhang, Yu [1 ]
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet, New York, NY 10010 USA
[2] Univ Geneva, Sch Dent Med, Div Fixed Prosthodont & Occlus, CH-1205 Geneva, Switzerland
基金
美国国家科学基金会;
关键词
Zirconia-ceramic FDPs; Metal-ceramic FDPs; Descriptive fractography; Occlusal wear facet; Chipping; Delamination; BRITTLE MATERIALS SUBJECT; COMPETING FRACTURE MODES; DENSELY SINTERED ALUMINA; LIQUID ENVIRONMENTS; COMPLICATION RATES; VENEERED ZIRCONIA; PARTIAL DENTURES; FAILURE ANALYSIS; FATIGUE DAMAGE; RESISTANCE;
D O I
10.1016/j.dental.2015.07.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. A recent 3-year randomized controlled trial (RCT) of tooth supported three- to five-unit zirconia-ceramic and metal-ceramic posterior fixed dental prostheses (FDPs) revealed that veneer chipping and fracture in zirconia-ceramic systems occurred more frequently than those in metal-ceramic systems [1]. This study seeks to elucidate the underlying mechanisms responsible for the fracture phenomena observed in this RCT using a descriptive fractographic analysis. Methods. Vinyl-polysiloxane impressions of 12 zirconia-ceramic and 6 metal-ceramic FDPs with veneer fractures were taken from the patients at the end of a mean observation of 40.3 +/- 2.8 months. Epoxy replicas were produced from these impressions H. All replicas were gold coated, and inspected under the optical microscope and scanning electron microscope (SEM) for descriptive fractography. Results. Among the 12 zirconia-ceramic FDPs, 2 had small chippings, 9 had large chippings, and 1 exhibited delamination. Out of 6 metal-ceramic FDPs, 5 had small chippings and 1 had large chipping. Descriptive fractographic analysis based on SEM observations revealed that fracture initiated from the wear facet at the occlusal surface in all cases, irrespective of the type of restoration. Significance. Zirconia-ceramic and metal-ceramic FDPs all fractured from microcracks that emanated from occlusal wear facets. The relatively low fracture toughness and high residual tensile stress in porcelain veneer of zirconia restorations may contribute to the higher chipping rate and larger chip size in zirconia-ceramic FDPs relative to their metal-ceramic counterparts. The low veneer/core interfacial fracture energy of porcelain-veneered zirconia may result in the occurrence of delamination in zirconia-ceramic FDPs. 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1198 / 1206
页数:9
相关论文
共 50 条
  • [21] Fatigue Behavior of Zirconia-Ceramic, Galvano-Ceramic, and Porcelain-Fused-to-Metal Fixed Partial Dentures
    Eroglu, Zekiye
    Gurbulak, Aysegul G.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (07): : 516 - 522
  • [22] Up to 10 years clinical performance of zirconia ceramic and metal-ceramic fixed partial dentures: A retrospective study
    Rathmann, Friederike
    Pohl, Moritz
    Rammelsberg, Peter
    Boemicke, Wolfgang
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (04): : 756 - 765
  • [23] In vitro comparison of the load-bearing capacity of ceramic and metal-ceramic resin-bonded fixed dental prostheses in the posterior region
    Boemicke, Wolfgang
    Waldecker, Moritz
    Krisam, Johannes
    Rammelsberg, Peter
    Rues, Stefan
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (01): : 89 - 96
  • [24] Outcome of bonded vs all-ceramic and metal-ceramic fixed prostheses for single tooth replacement
    Karl, Matthias
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2016, 9 (02) : S25 - S44
  • [25] CAD/CAM Single Retainer Zirconia-Ceramic Resin-Bonded Fixed Dental Prostheses: Clinical Outcome after 5 Years
    Sasse, M.
    Kern, M.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2013, 16 (02) : 109 - 118
  • [26] Common post-fitting complications in tooth-supported fixed-fixed design metal-ceramic fixed dental prostheses
    Zafar, Nadia
    Ghani, Fazal
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2014, 30 (03) : 619 - 625
  • [27] Clinical Survival of Anterior Metal-Ceramic and All-Ceramic Cantilever Resin-Bonded Fixed Dental Prostheses over a Period of 60 Months
    Saker, Samah
    El-Fallal, Abeer
    Abo-Madina, Manal
    Ghazy, Mohamed
    Oezcan, Mutlu
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2014, 27 (05) : 422 - 424
  • [28] Comparison of technical, biological, and esthetic parameters of ceramic and metal-ceramic implant-supported fixed dental prostheses: A systematic review and meta-analysis
    Hu, Meng-Long
    Lin, Hong
    Zhang, You-Dong
    Han, Jian-Min
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (01): : 26 - +
  • [29] Comparison of Metal-Ceramic and All-Ceramic Three-Unit Posterior Fixed Dental Prostheses: A 3-Year Randomized Clinical Trial
    Nicolaisen, Maj H.
    Bahrami, Golnosh
    Schropp, Lars
    Isidor, Flemming
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (03) : 259 - 264
  • [30] Survival of Resin-Bonded Fixed Metal-Ceramic Dental Prostheses Placed in the Anterior Region: A Descriptive Cross-sectional Study
    Bhusal, Dinesh Sharma
    Khanal, Sunita
    Parajuly, Prakash Kumar
    JOURNAL OF NEPAL MEDICAL ASSOCIATION, 2021, 59 (237) : 494 - 497