Assessment of the test-retest reliability of laboratory polysomnography

被引:103
|
作者
Levendowski, Daniel J. [1 ]
Zack, Nadene [2 ]
Rao, Srini [2 ]
Wong, Keith [3 ]
Gendreau, Michael [2 ]
Kranzler, Jay [2 ]
Zavora, Timothy [1 ]
Westbrook, Philip R. [1 ]
机构
[1] Adv Brain Monitoring Inc, Carlsbad, CA 92008 USA
[2] Cypress Biosci Inc, San Diego, CA 92121 USA
[3] Univ Sydney, Woolcock Inst Med Res, Sydney, NSW 2006, Australia
关键词
Polysomnography; Repeated measures; Reliability; Treatment outcome; Case finding; OBSTRUCTIVE SLEEP-APNEA; PARAMETERS; AGREEMENT; POSITION; INDEXES; NIGHT;
D O I
10.1007/s11325-008-0214-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
When conducting a treatment intervention study, it is assumed that a level of reliability can be obtained from the measurement tool such that the outcome can be reasonably assessed. Investigate the reliability of laboratory polysomnography, the gold standard for assessment of treatment outcomes for obstructive sleep apnea, at a 1-month interval. In a clinical trial of 118 patients recruited to assess the effects of a pharmaceutical treatment intervention, a subset of 20 patients designated as placebo controls completed two polysomnography studies, one at baseline and one at least one month later. The correlation between the overall Apnea/Hypopnea indices from the two polysomnography (PSG) studies was poor (r = 0.44) and the results were biased, with a mean increase of seven events per hour on night 2. Twenty-five percent of the subjects had an increase greater than 20 events/hour on night 2 and only 45% of participants had a night-to-night difference of a parts per thousand currency sign5 events/hour. The correlation between overall apnea indexes for nights 1 and 2 (r = 0.61) was improved, compared to the overall apnea/hypopnea indexes. The correlation in sleep efficiency across the two nights was relatively week (r = 0.52) but significant. The correlations between nights 1 and 2 for the percentage of time supine (r = 0.70) and the supine apnea-hypopnea index (AHI) (r = 0.69) were similar and highly significant. The correlation for the non-supine AHI was only 0.25 In this study, the reliability of a single-night PSG in measuring treatment outcome was compromised as a result of the large night-to-night variability of subjects' obstructive sleep apnea (OSA). Studies employing the AHI as an outcome need to be adequately powered with respect to the inherent night-to-night variability in the measurement. When assessing treatment intervention outcomes, there may be benefit from the acquisition and averaging of multiple nights of data in order to mitigate the inherent night-to-night variability of OSA and improve the accuracy of the outcome assessment.
引用
收藏
页码:163 / 167
页数:5
相关论文
共 50 条
  • [21] Test-retest reliability of the Preschool Age Psychiatric Assessment (PAPA)
    Egger, HL
    Erkanli, A
    Keeler, G
    Potts, E
    Walter, BK
    Angold, A
    JOURNAL OF THE AMERICAN ACADEMY OF CHILD AND ADOLESCENT PSYCHIATRY, 2006, 45 (05): : 538 - 549
  • [22] Test-Retest Reliability of Multiple Postural Control Assessment Measures
    Mormile, Megan E.
    Szekely, Brian J.
    Grimes, Katelyn E.
    Mizeski, Brian J.
    Munkasy, Barry A.
    Powell, Douglas W.
    Murray, Nicholas G.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 314 - 314
  • [23] Test-Retest Reliability of Audiometric Assessment in Individuals With Mild Dementia
    McClannahan, Katrina S.
    Chiu, Yi-Fang
    Sommers, Mitchell S.
    Peelle, Jonathan E.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2021, 147 (05) : 442 - 449
  • [24] TEST-RETEST RELIABILITY OF THE CHILDREN OF ALCOHOLICS TEST
    ROBINSON, BE
    POST, P
    WEBB, W
    SMITH, EJ
    PERCEPTUAL AND MOTOR SKILLS, 1990, 70 (03) : 858 - 858
  • [25] Test-retest and interrater reliability of Barcelona test
    Serra-Mayoral, A.
    Pena-Casanova, J.
    NEUROLOGIA, 2006, 21 (06): : 277 - 281
  • [26] Test-Retest Reliability of a Functional Reaction Time Assessment Battery
    Lynall, Robert C.
    Johnson, Rachel S.
    Lempke, Landon B.
    Schmidt, Julianne D.
    JOURNAL OF SPORT REHABILITATION, 2021, 30 (08) : 1237 - 1241
  • [27] Test-retest reliability of the purdue pegboard test
    Buddenberg, LA
    Davis, C
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 2000, 54 (05): : 555 - 558
  • [28] Test-retest Reliability Of An Isokinetic Fatigue Test
    Ramos, Giovanna C.
    Neltner, Tyler J.
    Grammer, Emily E.
    Addie, Cameron J.
    Straughn, Marisa K.
    Glenn, Jordan M.
    Gray, Michelle
    Moyen, Nicole E.
    Vincenzo, Jennifer L.
    Harmon, Kylie K.
    Brown, Lee E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 925 - 925
  • [29] TEST-RETEST RELIABILITY OF THE BLACKY PICTURES TEST
    BERGER, L
    EVERSTINE, L
    JOURNAL OF PROJECTIVE TECHNIQUES & PERSONALITY ASSESSMENT, 1962, 26 (02): : 225 - 226
  • [30] How to assess test-retest reliability of a test?
    Schuck, P
    INTERNATIONAL JOURNAL OF PSYCHOLOGY, 2000, 35 (3-4) : 318 - 318