Time-of-flight MR angiography targeted to coiled intracranial aneurysms is more sensitive to residual flow than is digital subtraction angiography

被引:1
|
作者
Yamada, N
Hayashi, K
Murao, K
Higashi, M
Iihara, K
机构
[1] Natl Cardiovasc Ctr, Dept Radiol & Nucl Med, Suita, Osaka 5658565, Japan
[2] Natl Cardiovasc Ctr, Dept Neurosurg, Suita, Osaka 5658565, Japan
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: For intracranial aneurysms treated with Guglielmi detachable coils, long-term follow-up is mandatory because coil compaction may occur and aneurysms may recur. The purpose of this study was to establish a noninvasive technique to visualize residual flow in coiled aneurysms. METHODS: We designed a 3D time-of-flight (3D-TOF) MR angiography (MRA) technique targeted to depict coiled aneurysms that employed a very short TE (1.54-1.60 ms) and a high spatial resolution (0.3 x 0.3 x 0.3 mm(3) with zero-filling) to diminish spin dephasing. To diminish spin saturation, image volume was carefully positioned so that the neck of the targeted aneurysm was within 2 cm of the inflow portion along the stream of blood. Fifty-one MRA images of 39 coiled aneurysms in 39 patients were compared with digital subtraction angiography (DSA) images. DSA and MRA findings were interpolated retrospectively for parent and branch arteries' patency, as well as residual How in aneurysms. In the latest 11 MR studies, a dark-blood 3D turbo spin-echo sequence was added to MRA to negate the effect high-signal-intensity thrombus. RESULTS: MRA visualized all parent and branch arteries with DSA confirmation. MRA visualized residual flow more frequently (38 studies) than did DSA (25 studies). Residual flow space visualized with MRA was always similar to or larger than that with DSA. The dark-blood sequence completely suppressed intraluminal high signal intensity on MRA images and confirmed that the high signal intensity was not due to thrombus. CONCLUSION. TOF MRA targeted to depict coiled intracranial aneurysms is noninvasive and superior to DSA in visualization of residual flow and, hence, useful for follow-up of coiled aneurysms.
引用
收藏
页码:1154 / 1157
页数:4
相关论文
共 50 条
  • [41] Replacing Digital Subtraction Angiography by Magnetic Resonance Angiography for Follow-up of Coiled Intracranial Aneurysms: a Cost Effectiveness Analysis.
    Schaafsma, Joanna
    Koffijberg, Hendrilk
    Velthuis, Birgitta
    Buskens, Erik
    van der Yolanda, Graaf
    Rinkel, Gabriel
    STROKE, 2009, 40 (04) : E271 - E272
  • [42] Comparing the Accuracy of Digital Subtraction Angiography, CT Angiography and MR Angiography at Estimating the Volume of Cerebral Aneurysms
    Hanley, M.
    Zenzen, W. J.
    Brown, M. D.
    Gaughen, J. R.
    Evans, A. J.
    INTERVENTIONAL NEURORADIOLOGY, 2008, 14 (02): : 173 - 177
  • [43] Quantification of Blood Flow in Internal Cerebral Artery by Optical Flow Method on Digital Subtraction Angiography in Comparison with Time-Of-Flight Magnetic Resonance Angiography
    Huang, Tzung-Chi
    Chang, Chih-Kai
    Liao, Chun-Han
    Ho, Yung-Jen
    PLOS ONE, 2013, 8 (01):
  • [44] Phase Enhancement for Time-of-Flight and Flow-Sensitive Black-Blood MR Angiography
    Kimura, Tokunori
    Ikedo, Masato
    Takemoto, Shuhei
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 437 - 447
  • [45] Value of CT-angiography (CTA) in patients with intracranial aneurysms. Comparison with MR-angiography (MRA) and digital subtraction angiography (DSA)
    Eberhardt, KEW
    Tomandl, B
    Huk, WJ
    Laumer, R
    Fahlbusch, R
    11TH INTERNATIONAL CONGRESS OF NEUROLOGICAL SURGERY, VOLS 1 AND 2, 1997, : 1963 - 1967
  • [46] TIME-OF-FLIGHT MR ANGIOGRAPHY IN EXTREMITY TRAUMA
    DAVIS, SH
    TEITELBAUM, GP
    COLLETTI, PM
    DZIUBINSKI, JE
    PENTECOST, MJ
    FINCK, EJ
    RADIOLOGY, 1990, 174 (03) : 1062 - 1063
  • [47] Computer simulation of Time-of-Flight MR angiography
    Jia, LH
    Hiller, J
    Lambert, T
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XIX, 1996, 2847 : 548 - 558
  • [48] Intracranial vascular stenosis and occlusive disease: Evaluation with CT angiography, MR angiography, and digital subtraction angiography
    Bash, S
    Villablanca, JP
    Jahan, R
    Duckwiler, G
    Tillis, M
    Kidwell, C
    Saver, J
    Sayre, J
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (05) : 1012 - 1021
  • [49] HIGH-VELOCITY FLOW DETECTED WITH PHASE-CONTRAST MR ANGIOGRAPHY BUT NOT WITH TIME-OF-FLIGHT MR ANGIOGRAPHY
    COUSINS, JP
    WAGLE, WA
    ZIRINSKY, K
    DUMOULIN, CL
    RADIOLOGY, 1992, 185 : 203 - 204
  • [50] INVESTIGATION OF TIME-OF-FLIGHT MR ANGIOGRAPHY IN THE PRESENCE OF TURBULENT-FLOW
    ORTEGA, HV
    VINITSKI, S
    MOHAMED, FB
    MITCHELL, DG
    CHO, YI
    SESHAGIRI, S
    RADIOLOGY, 1992, 185 : 222 - 222