Design and Reliability of a Novel Heel Rise Test Measuring Device for Plantarflexion Endurance

被引:30
|
作者
Sman, Amy D. [1 ]
Hiller, Claire E. [1 ]
Imer, Adam [1 ]
Ocsing, Aldrin [1 ]
Burns, Joshua [1 ,2 ]
Refshauge, Kathryn M. [1 ]
机构
[1] Univ Sydney, Fac Hlth Sci, Discipline Physiotherapy, Lidcombe, NSW 1825, Australia
[2] Childrens Hosp Westmead, Inst Neurosci & Muscle Res, Westmead, NSW 2145, Australia
关键词
FLEXION; INJURY;
D O I
10.1155/2014/391646
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background. Plantarflexion results from the combined action of the soleus and gastrocnemius muscles in the calf. The heel rise test is commonly used to test calf muscle endurance, function, and performance by a wide variety of professionals; however, no uniform description of the test is available. This paper aims to document the construction and reliability of a novel heel rise test device and measurement protocol that is suitable for the needs of most individuals. Methods. This device was constructed from compact and lightweight materials and is fully adjustable, enabling the testing of a wide variety of individuals. It is easy to assemble and disassemble, ensuring that it is portable for use in different settings. Findings. We tested reliability on 40 participants, finding excellent interrater reliability (ICC2,1 0.97, 95% CI: 0.94 to 0.98). Limits of agreement were less than two repetitions in 90% of cases and the Bland-Altman plot showed no bias. Interpretation. We have designed a novel, standardized, simple, and reliable device and measurement protocol for the heel rise test which can be used by researchers and clinicians in a variety of settings.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Validation of a New Device for Measuring Isolated Gastrocnemius Contracture and Evaluation of the Reliability of the Silfverskiold Test
    Molund, Marius
    Husebye, Elisabeth Ellingsen
    Nilsen, Fredrik
    Hellesnes, Jan
    Berdal, Goran
    Hvaal, Kjetil Harald
    FOOT & ANKLE INTERNATIONAL, 2018, 39 (08) : 960 - 965
  • [22] Test-retest reliability and validity of a newly instrumented device for measuring trunk extensor muscles endurance in healthy male participants: a randomized cross-over study
    Hosseinzadeh, Mahdi
    Assar, Saleh
    Soltanirad, Shabnam
    Letafatkar, Amir
    Hoogenboom, Barbara J.
    Benoit, Colleen
    Kazemi, Abdolreza
    Smania, Nicola
    Rossettini, Giacomo
    SPORT SCIENCES FOR HEALTH, 2024, 20 (03) : 853 - 861
  • [23] Endurance Test for Evaluating the Performances of a Novel Rotating-Cylinder-Type Triboelectric Charging Device
    Achouri, Imed Eddine
    Zeghloul, Thami
    Richard, Gontran
    Medles, Karim
    Dascalescu, Lucian
    Senouci, Khouira
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (06) : 7005 - 7011
  • [24] A novel design of a wearable device for measuring force and torque in vascular surgery
    Wang, Dangxiao
    Yang, Cailing
    Zhang, Yuru
    Xiao, Jing
    Dong, Yongpan
    Wang, Tiange
    2013 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2013, : 2374 - 2379
  • [25] Design of Reliability Qualification Test for an Underwater Electronic Device Based on Arrhenius Formula
    Li, Qi
    Wu, Sa
    Zhang, Qian
    2015 PROGNOSTICS AND SYSTEM HEALTH MANAGEMENT CONFERENCE (PHM), 2015,
  • [26] Comparative Reliability of a Novel Electromechanical Device and Handheld Ruler for Measuring First Ray Mobility
    Morgan, Oliver J.
    Hillstrom, Rajshree
    Turner, Robert
    Day, Jonathan
    Thaqi, Ibadet
    Caolo, Kristin
    Song, Jinsup
    Russell, Roland
    Ellis, Scott
    Deland, Jonathan T.
    Hillstrom, Howard J.
    FOOT & ANKLE INTERNATIONAL, 2021, 42 (12) : 1613 - 1623
  • [27] Test-Retest Reliability of a Motorized Resistance Device for Measuring Throwing Performance in Volleyball Athletes
    Paraskevopoulos, Eleftherios
    Christakou, Anna
    Plakoutsis, George
    Pamboris, George M.
    Papandreou, Maria
    BIOMECHANICS, 2024, 4 (02): : 259 - 268
  • [28] The design and realization of on-line measuring device of busbar temperature rise for HV switch board
    Zeng Linsuo
    Wang Maojun
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 171 - +
  • [29] Measuring change in parotid gland size: Test-retest reliability of a novel method
    Clare M.
    Gritzner S.
    Hlynsky J.
    Birmingham C.L.
    Eating and Weight Disorders - Studies on Anorexia, Bulimia and Obesity, 2005, 10 (3) : e61 - e65
  • [30] SHOULDER PROPRIOCEPTION DEVICE (SPD): A NOVEL DESIGN FOR MEASURING SHOULDER JOINT PROPRIOCEPTION
    Schnipke, Jeremy R.
    Rounds, Thomas G.
    Sroka, Jacob P.
    Lowe, Zachary B.
    Freisinger, Gregory M.
    Nowicki, Margaret A.
    Cameron, Kenneth L.
    Hotaling, Brittany R.
    Westrick, Richard B.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 3, 2020,