Cervical Spine Motion A Fluoroscopic Comparison of the AirTraq Laryngoscope versus the Macintosh Laryngoscope

被引:71
|
作者
Turkstra, Timothy P. [1 ]
Pelz, David M.
Jones, Philip M.
机构
[1] Univ Western Ontario, Dept Anesthesia & Perioperat Med, London Hlth Sci Ctr, London, ON N6A 5A5, Canada
关键词
ENDOTRACHEAL INTUBATION; OROTRACHEAL INTUBATION; AIRWAY MANAGEMENT; MOVEMENT; INJURY;
D O I
10.1097/ALN.0b013e3181a8649f
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The optimal technique to intubate the trachea in patients presenting with a potential or documented cervical spine (C-spine) injury remains unresolved. Using continuous fluoroscopic video assessment, C-spine motion during laryngoscopy with an AirTraq Laryngoscope (R) (King Medical Systems, Newark, DE) was compared to that with intubation using a Macintosh blade. Methods: Twenty-four healthy surgical patients gave written consent to participate in a crossover randomized controlled trial; all patients were subjected to both Macintosh and AirTraq laryngoscopy with manual inline stabilization after induction of anesthesia. The C-spine motion was examined at four areas: the occiput-C1 junction, C1-C2 junction, C2-C5 motion segment, and C5-thoracic motion segment. The time required for laryngoscopy was also measured. Results: C-spine motion using the AirTraq was less than that during Macintosh laryngoscopy, averaging 66% less (P < 0.01) at three of the motion segments studied, occiput-C1, C2-C5, and C5-thoracic. There was no difference at the C1-C2 segment. There was no significant difference in the time to accomplish laryngoscopy between the two devices. Conclusions: For patients in whom C-spine movement is undesirable, use of the AirTraq Laryngoscope (R) may be useful to limit movement without an increase in the duration of intubation.
引用
收藏
页码:97 / 101
页数:5
相关论文
共 50 条
  • [21] Comparison of Airtraq™ video-laryngoscope and Macintosh laryngoscope for tracheal intubation in adults-a randomised study
    Meena, Seema
    Chaudhary, Sujata
    Salhotra, Rashmi
    Bharti, Swati
    Khurana, Bismanjeet Kaur
    AIN SHAMS JOURNAL OF ANESTHESIOLOGY, 2023, 15 (01)
  • [22] Comparing Performance of Airtraq Versus Macintosh Laryngoscope for Pediatric Intubation by Novices
    Li, Hui-Xian
    Liu, Ya-Yang
    Yang, Gui-Zhen
    Xue, Fu-Shan
    PEDIATRIC EMERGENCY CARE, 2018, 34 (10) : E196 - E196
  • [23] Cervical spine movements during laryngoscopy - Comparison of the Macintosh and McCoy laryngoscope blades
    MacIntyre, PA
    McLeod, ADM
    Hurley, R
    Peacock, C
    ANAESTHESIA, 1999, 54 (05) : 413 - 418
  • [24] A comparison of Airtraq™ laryngoscope and standard direct laryngoscopy in adult patients with immobilized cervical spine
    Amor, M.
    Nabil, S.
    Bensghir, M.
    Moussaoui, A.
    Kabbaj, S.
    Kamili, N. Drissi
    Maazouzi, W.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 (05): : 296 - 301
  • [25] Airtraq laryngoscope has an advantage over Macintosh laryngoscope for nasotracheal intubation by novice laryngoscopists
    Yoshihiro Hirabayashi
    Norimasa Seo
    Journal of Anesthesia, 2009, 23 : 172 - 173
  • [26] Airtraq laryngoscope has an advantage over Macintosh laryngoscope for nasotracheal intubation by novice laryngoscopists
    Hirabayashi, Yoshihiro
    Seo, Norimasa
    JOURNAL OF ANESTHESIA, 2009, 23 (01) : 172 - 173
  • [27] Teaching tracheal intubation: Airtraq is superior to Macintosh laryngoscope
    Zhao, Hong
    Feng, Yi
    Zhou, Yanyan
    BMC MEDICAL EDUCATION, 2014, 14
  • [28] Teaching tracheal intubation: Airtraq is superior to Macintosh laryngoscope
    Hong Zhao
    Yi Feng
    Yanyan Zhou
    BMC Medical Education, 14
  • [29] Comparison of two strategies for tracheal intubation in morbidly obese patients: conventional with Macintosh laryngoscope versus Face in patient sitting with the Airtraq™ video laryngoscope
    Zraier, S.
    Amathieu, R.
    Haouache, H.
    Chemit, M.
    Slavov, V.
    Dababi, M.
    Allouche, N.
    Bloc, S.
    Dhonneur, G.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 : A111 - A111
  • [30] COMPARISON OF THE KING VISION VIDEO LARYNGOSCOPE WITH THE MACINTOSH LARYNGOSCOPE
    Murphy, Laurel D.
    Kovacs, George J.
    Reardon, Peter M.
    Law, John Adam
    JOURNAL OF EMERGENCY MEDICINE, 2014, 47 (02): : 239 - 245