Stray Load Loss Valuation in Electrical Transformers: A Review

被引:5
|
作者
Thango, Bonginkosi A. [1 ]
Bokoro, Pitshou N. [1 ]
机构
[1] Univ Johannesburg, Dept Elect & Elect Engn Technol, ZA-2006 Johannesburg, South Africa
关键词
transformer; stray load loss; hotspot; harmonics; TANK-WALL LOSSES;
D O I
10.3390/en15072333
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The electricity production opus in South Africa has transformed over the last few years from predominantly coal power generation to a blend of renewable energy generation. The necessity emerges to ascertain whether electrical transformer design philosophies in local manufacturers are contemporary in reference to customer specifications, under increasing penetration of harmonics and distortion as a result of increasing deployment of decentralized power systems. Accurate computation of transformer stray load loss is imperative in localizing the hotspot regions and design of adequate insulation system and consequently cooling system. This loss must also be met by manufacturers based on the customer specifications to avoid penalties. The review of current scientific works affirms the ongoing interest in utilizing the advancement of computational power for painstaking evaluation and management of stray load loss in electric transformers. This article confers overview research, evolution and application of diverse computer-based tools for analyzing the stray load loss based on over 60 published scientific works. Mathematical formulations that can be practically employed by transformer designers during the design phase under normal and harmonic load current conditions are discussed.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] The study of the stray load loss and mechanical loss of three phase induction motor considering experimental results
    Kim, Dong-Jun
    Choi, Jae-Hak
    Chun, Yon-Do
    Koo, Dae-Hyun
    Han, Pil-Wan
    Journal of Electrical Engineering and Technology, 2014, 9 (01): : 121 - 126
  • [32] The Study of the Stray Load Loss and Mechanical Loss of Three Phase Induction Motor considering Experimental Results
    Kim, Dong-Jun
    Choi, Jae-Hak
    Chun, Yon-Do
    Koo, Dae-Hyun
    Han, Pil-Wan
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (01) : 121 - 126
  • [33] Corrected harmonic loss factor for transformers supplying nonsinusoidal load currents
    Makarov, SN
    Emanuel, AE
    NINTH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER PROCEEDINGS, VOLS I - III, 2000, : 87 - 90
  • [35] Stray Loss Evaluation of Power Transformers Using Simplified Air-Core Model With Tank and Frame
    Liu, Botao
    Takahashi, Yasuhito
    Fujiwara, Koji
    Imamori, Satoshi
    IEEE TRANSACTIONS ON MAGNETICS, 2023, 59 (11)
  • [36] Reluctance Model of the Stray Field in Transformers.
    Turowski, Janusz
    Rozprawy Elektrotechniczne, 1984, 30 (04): : 1121 - 1144
  • [37] A new Zig-Zag Variable Load Test Approach for Enhanced Stray-Load Loss Measurements
    Vaschetto, Silvio
    Cavagnino, Andrea
    Agamloh, Emmanuel B.
    Tenconi, Alberto
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 2294 - 2300
  • [38] ELECTRICAL TRANSFORMERS
    BROWN, T
    CADICK, JL
    CHEMICAL ENGINEERING, 1979, 86 (03) : 111 - 115
  • [39] Compensation of stray load loss induced detuning in rotor flux oriented induction machines
    Lamine, A.
    Levi, E.
    Cavagnino, A.
    PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 685 - +
  • [40] The Reduction Method of a Stray Load Loss of Distribution Transformer on the Bushing Flange Plate with STS
    Sang-Hyun Kim
    Jung-Kyu Jin
    Young-Joo Kim
    Bum-In Shin
    Hyang-Beom Lee