Comparison between On-Line High-Efficiency Hemodiafiltration and Conventional High-Flux Hemodialysis for Polyclonal Free Light Chain Removal

被引:11
|
作者
Lamy, Thomas [1 ]
Henri, Patrick [1 ]
Lobbedez, Thierry [1 ]
Comby, Elisabeth [2 ]
Ryckelynck, Jean-Philippe [1 ]
Ficheux, Maxence [1 ]
机构
[1] CHU Clemenceau, Dept Nephrol, FR-14033 Caen, France
[2] CHU Clemenceau, Dept Immunol, FR-14033 Caen, France
关键词
Hemodialysis; Hemodiafiltration; Polyclonal free light chains; SERUM; DIALYSIS; HEMOFILTRATION; MORTALITY; BETA-2-MICROGLOBULIN; CLEARANCE; RISK;
D O I
10.1159/000357968
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Polyclonal free light chains (FLC) are considered as middle molecular weight uremic toxins in chronic kidney disease. In this study, we investigate polyclonal FLC removal by comparing conventional high-flux hemodialysis (HD) and online high-efficiency hemodiafiltration (ol-HDF) in end-stage renal disease patients. Methods: We analyzed 31 chronic dialysis patients who were treated by HD then by postdilution ol-HDF during a prospective study. All patients were anuric and without monoclonal gammopathy. Serum pre- and postdialysis FLC were collected during 4 sessions: 1 HD session and 3 ol-HDF sessions. We calculated the reduction ratio using kinetic modeling. Results: The kappa reduction ratio was higher with ol-HDF than with HD (66 +/- 14 vs. 52 +/- 13%, p < 0.001). However, the lambda reduction ratio was not significantly higher with ol-HDF (37 +/- 20 vs. 37 +/- 15%, p = 0.67). Furthermore, predialysis kappa- and lambda-FLC increased with ol-HDF compared with HD (kappa 155 +/- 82 vs. 87 +/- 47 mg/l, p < 0.05; lambda 101 +/- 46 vs. 72 +/- 41 mg/l, p < 0.05). Postdialysis FLC levels were raised only for lambda-FLC with ol-HDF (74 +/- 39 vs. 53 +/- 31 mg/l, p < 0.05) and were not significantly different for kappa. Conclusions: This study shows that lambda-FLC removal is better in ol-HDF compared with HD, whereas there is no difference in kappa-FLC removal. Surprisingly, predialysis kappa and lambda levels are both increased in ol-HDF, which is disturbing since polyclonal excess of lambda-FLC is associated with mortality in chronic kidney disease. (C) 2014 S. Karger AG, Basel
引用
收藏
页码:93 / 98
页数:6
相关论文
共 50 条
  • [21] REMOVAL EFFICIENCY OF PROTEIN BOUND SOLUTES AND ANTIOXIDANTS BY ONLINE HEMODIAFILTRATION COMPARED WITH HIGH-FLUX HEMODIALYSIS
    Okano, Kazuhiro
    Tsuchiya, Ken
    Nitta, Kosaku
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2016, 31 : 231 - 232
  • [22] Removal and Rebound Kinetics of Cystatin C in High-Flux Hemodialysis and Hemodiafiltration
    Vilar, Enric
    Boltiador, Capella
    Viljoen, Adie
    Machado, Ashwini
    Farrington, Ken
    CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2014, 9 (07): : 1240 - 1247
  • [23] Extended High Cutoff On-Line Hemodiafiltration Is Superior to Extended High Cutoff Hemodialysis in Removal of Free Light Chain Immunoglobulin of Myeloma Cast Nephropathy
    Susantitaphong, Paweena
    Tiranathanagul, Khajohn
    Eiam-Ong, Somchai
    ARTIFICIAL ORGANS, 2012, 36 (09) : 845 - 846
  • [24] Comparison of Survival between Dialysis Patients with Incident High-Flux Hemodialysis versus On-Line Hemodiafiltration: A Single Center Experience in Saudi Arabia
    Abdelsalam, Mohamed Said
    Rashwan, Mohamed
    Althaf, Mohamed Mahdi
    Alfurayh, Osman I.
    Alkorbi, Lutfi
    Ibrahim, Ihab A.
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2018, 29 (01) : 107 - 113
  • [25] High-flux on-line hemodiafiltration with polyethersulfone membranes:: Performances in hemodiafiltration and impact of glucose administration
    Senécal, L
    Krieter, DH
    Moragues, HL
    Martin, K
    Canaud, B
    POLYETHERSULFONE: MEMBRANES FOR MULTIPLE CLINICAL APPLICATIONS, 2003, 138 : 88 - 98
  • [26] High-Flux Dialysis: Clinical, Biochemical, and Proteomic Comparison with Low-Flux Dialysis and On-Line Hemodiafiltration
    Donadio, Carlo
    Kanaki, Angeliki
    Sami, Nadia
    Tognotti, Danika
    BLOOD PURIFICATION, 2017, 44 (02) : 129 - 139
  • [27] Evolution of high sensitivity troponin-T in patients undergoing high efficiency on-line hemodiafiltration versus conventional low-flux hemodialysis
    Ethier, I.
    Cardinal, H.
    Beaulieu, M.
    Grooteman, M. P. C.
    Nube, M. J.
    Levesque, R.
    Auger, D.
    EUROPEAN HEART JOURNAL, 2015, 36 : 924 - 925
  • [28] Oxidative Status before and after Renal Replacement Therapy: Differences between Conventional High Flux Hemodialysis and on-Line Hemodiafiltration
    Alberto Navarro-Garcia, Jose
    Rodriguez-Sanchez, Elena
    Aceves-Ripoll, Jennifer
    Abarca-Zabalia, Judith
    Susmozas-Sanchez, Andrea
    Gonzalez Lafuente, Laura
    Bada-Bosch, Teresa
    Hernandez, Eduardo
    Merida-Herrero, Evangelina
    Praga, Manuel
    Miguel Ruilope, Luis
    Ruiz-Hurtado, Gema
    NUTRIENTS, 2019, 11 (11)
  • [29] Compared efficiency of on-line HDF and high-flux HD
    García, H
    Hernández-Jaras, J
    Maduell, F
    Yago, M
    Calvo, C
    Navarro, V
    Villatoro, J
    NEFROLOGIA, 1998, 18 (06): : 476 - 482
  • [30] COST-OPTIMIZATION OF DIALYSATE FLOW FOR HIGH-FLUX HIGH-EFFICIENCY HEMODIALYSIS