WHO Multicenter Evaluation of FACSCount CD4 and Pima CD4 T-Cell Count Systems: Instrument Performance and Misclassification of HIV-Infected Patients

被引:0
|
作者
Wade, Djibril [1 ,2 ,3 ]
Daneau, Geraldine [1 ]
Aboud, Said [4 ]
Vercauteren, Gaby H. [5 ]
Urassa, Willy S. K. [5 ]
Kestens, Luc [1 ,3 ]
机构
[1] Inst Trop Med Antwerp, Dept Biomed Sci, Immunol Lab, Antwerp, Belgium
[2] Univ Cheikh Anta Diop, Le Dantec Univ Teaching Hosp, Lab Bacteriol Virol, Immunol Unit, Dakar 92000, Senegal
[3] Univ Antwerp, Dept Biomed Sci, B-2020 Antwerp, Belgium
[4] Muhimbili Univ Hlth & Allied Sci, Dept Microbiol & Immunol, Dar Es Salaam, Tanzania
[5] WHO, CH-1211 Geneva, Switzerland
关键词
CD4; count; CD4%; resource-limited settings; Pima CD4; FACSCount CD4; POINT-OF-CARE; FLOW-CYTOMETRY; VIRAL LOAD; LYMPHOCYTE COUNTS; ENUMERATION; ANALYZER; SETTINGS; BLOOD; INDIVIDUALS; VALIDATION;
D O I
暂无
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background: CD4(+) T-cell counts are used to screen and follow-up HIV-infected patients during treatment. As part of the World Health Organization prequalification program of diagnostics, we conducted an independent multicenter evaluation of the FACSCount CD4 and the Pima CD4, using the FACSCalibur as reference method. Methods: A total of 440 paired capillary and venous blood samples were collected from HIV-infected patients attending the HIV outpatient clinic in Antwerp, Belgium, and the HIV care and treatment center in Dar es Salam, Tanzania. Capillary blood was run on Pima analyzer, whereas venous blood was analyzed on FACSCount, Pima, and FACSCalibur instruments. Precision and agreement between methods were assessed. Results: The FACSCount CD4 results were in agreement with the FACSCalibur results with relative bias of 0.4% and 3.1% on absolute CD4 counts and an absolute bias of -0.6% and -1.1% on CD4% in Antwerp and Dar es Salam, respectively. The Pima CD4 results were in agreement with the FACSCalibur results with relative bias of -4.1% and -9.4% using venous blood and of -9.5% and -0.9% using capillary blood in Antwerp and Dar es Salam, respectively. At the threshold of 350 cells per microliter, the FACSCount CD4 and Pima CD4 using venous and capillary blood misclassified 7%, 9%, and 13% of patients, respectively. Conclusions: The FACSCount CD4 provides reliable CD4 counts and CD4% and is suitable for monitoring adult and pediatric HIV patients in moderate-volume settings. The Pima CD4 is more suitable for screening eligible adult HIV patients for antiretroviral treatment initiation in low-volume laboratories.
引用
收藏
页码:E98 / E107
页数:10
相关论文
共 50 条
  • [21] Correlation Analysis on Total Lymphocyte Count and CD4 Count in HIV-infected Patients: A Retrospective Evaluation
    Wang, Yuming
    Liang, Shuying
    Yu, Erman
    Guo, Jinling
    Li, Zizhao
    Wang, Zhe
    Du, Yukai
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2011, 31 (05) : 712 - 716
  • [22] CD4 lymphocyte percentage vs CD4 lymphocyte count as an immunological marker of oral candidiasis in HIV-infected patients
    Campo, J
    Bascones, A
    del Romero, J
    Castilla, J
    ORAL DISEASES, 2001, 7 (03) : 203 - 204
  • [23] Long-Term CD4 Cell Count Recovery among Thai Naive HIV-Infected Patients Initiating HAART at Low CD4 Cell Count
    Chaiwarith, Romanee
    Salee, Parichart
    Kotarathitithum, Wilai
    Sirisanthana, Thira
    Supparatpinyo, Khuanchai
    CURRENT HIV RESEARCH, 2009, 7 (03) : 340 - 345
  • [24] CD4(+) and CD8(+) T-cell trajectories during pregnancy in HIV-infected women
    Teigen, Nickolas
    Liff, Ingrid
    Reimers, Laura
    Miraz, Maria
    Sutton, Desmond
    Wright, Rodney
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2014, 210 (01) : S248 - S249
  • [25] Cytomegalovirus retinitis in HIV-infected patient with a normal CD4 count
    Cardine, S
    Kirch, O
    Labetoulle, M
    Offret, H
    Frau, E
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2001, 24 (09): : 971 - 974
  • [26] Trajectories of CD4 T-cell count, CD8 T-cell count, and CD4/CD8 ratio in patients with HIV and long-term virological suppression based on Yunnan HIV cohort
    Shu, Yuanlu
    Zhang, Mi
    Li, Jianjian
    Deng, Xuemei
    Liu, Jiafa
    Yang, Cuixian
    Dong, Xingqi
    HIV MEDICINE, 2025, 26 (01) : 70 - 80
  • [27] Lower Nadir Cd4 T-cell Count is a Strong Predictor of Endothelial Dysfunction in HIV Infected Patients
    Mogadam, Emad
    King, Kevin
    Shriner, Kimberly
    Chu, Karen
    Sondergaard, Anders
    Royal, Darlene
    Young, Kristal
    Kloner, Robert
    CIRCULATION RESEARCH, 2018, 123
  • [28] CD4 ENUMERATION IN HIV-INFECTED INDIVIDUALS
    LOPEZ, A
    CIUDAD, J
    CORDERO, M
    ORFAO, A
    EUROPEAN JOURNAL OF HISTOCHEMISTRY, 1994, 38 : 35 - 40
  • [29] Obesity among HIV-infected persons: impact of weight on CD4 cell count
    Crum-Cianflone, Nancy F.
    Roediger, Mollie
    Eberly, Lynn E.
    Vyas, Kurt
    Landrum, Mike L.
    Ganesan, Anuradha
    Weintrob, Amy C.
    Barthel, Robert Vincent
    Agan, Brian K.
    AIDS, 2010, 24 (07) : 1069 - 1072
  • [30] Adherence to antiretroviral therapy and CD4 T-cell count responses among HIV-infected injection drug users
    Wood, E
    Montaner, JSG
    Yip, B
    Tyndall, MW
    Schechter, MT
    O'Shaughnessy, MV
    Hogg, RS
    ANTIVIRAL THERAPY, 2004, 9 (02) : 229 - 235