Validity of a Portable Glucose, Total Cholesterol, and Triglycerides Multi-Analyzer in Adults

被引:30
|
作者
Coqueiro, Raildo da Silva [1 ]
Santos, Mateus Carmo [1 ]
Leal Neto, Joao de Souza [1 ]
de Queiroz, Bruno Morbeck [1 ]
Jardim Bruegger, Nelson Augusto [2 ]
Barbosa, Aline Rodrigues [1 ,3 ]
机构
[1] Univ Estadual Sudoeste Bahia, Dept Saude, Nucleo Estudos Epidemiol Envelhecimento NEPE, Jequie, BA, Brazil
[2] Univ Fed Rio Grande do Sul, Programa Posgrad Ciencias Movimento Humano, Porto Alegre, RS, Brazil
[3] Univ Fed Santa Catarina, Ctr Desportos, Dept Educ Fis, Florianopolis, SC, Brazil
关键词
blood glucose; capillary blood; cholesterol; hematologic tests; monitoring; triglycerides; METABOLIC SYNDROME; CAPILLARY BLOOD; ACCURACY; CONCORDANCE; VALIDATION; AGREEMENT; DISEASE; METERS;
D O I
10.1177/1099800413495953
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
This study investigated the accuracy and precision of the Accutrend Plus system to determine blood glucose, total cholesterol, and plasma triglycerides in adults and evaluated its efficiency in measuring these blood variables. The sample consisted of 53 subjects (>= 18 years). For blood variable laboratory determination, venous blood samples were collected and processed in a Labmax 240 analyzer. To measure blood variables with the Accutrend Plus system, samples of capillary blood were collected. In the analysis, the following tests were included: Wilcoxon and Student's t-tests for paired samples, Lin's concordance coefficient, Bland-Altman method, receiver operating characteristic curve, McNemar test, and k statistics. The results show that the Accutrend Plus system provided significantly higher values (p <= .05) of glucose and triglycerides but not of total cholesterol (p > .05) as compared to the values determined in the laboratory. However, the system showed good reproducibility (Lin's coefficient: glucose = .958, triglycerides = .992, total cholesterol = .940) and high concordance with the laboratory method (Lin's coefficient: glucose = .952, triglycerides = .990, total cholesterol = .944) and high sensitivity (glucose = 80.0%, triglycerides = 90.5%, total cholesterol = 84.4%) and specificity (glucose = 100.0%, triglycerides = 96.9%, total cholesterol = 95.2%) in the discrimination of high values of the three blood variables analyzed. It could be concluded that despite the tendency to overestimate glucose and triglyceride levels, a portable multi-analyzer is a valid alternative for the monitoring of metabolic disorders and cardiovascular risk factors.