摘要
Combined Heat and Power (CHP) scheme, also known as cogeneration is widely accepted as a highly efficient energy saving measure, particularly in medium to large scale chemical process plants. To date, CHP application is well established in, the developed countries. The advantage of a CHP scheme for a chemical plant is two-fold: (i) to drastically cut down on the electricity bill from on-site power generation (ii) to save on fuel bills through recovery of the quality waste heat from power generation for process heating. In order to be effective, a CHP scheme must be placed at the right temperature level in the context of the overall process. Failure to do so might render a CHP venture worthless. This paper discusses the procedure for an effective implementation of a CHP scheme. An. ethylbenzene process is used as a case study. A key visualisation tool known as the grand composite curves is used to provide an overall picture of the process heat source and heat sink profiles. The grand composite curves, which is generated based on the first principles of Pinch Analysis enables the CHP scheme to be optimally placed within the overall process scenario.
引用
收藏
页码:59 / 70
页数:12
相关论文
共 50 条
  • [21] Environmental protection and sustainable waste-to-energy scheme through plastic waste gasification in a combined heat and power system
    Li, Ji
    Song, Fumei
    Guo, Jingzhong
    Abed, Azher M.
    Alghassab, Mohammed A.
    Abdullaev, Sherzod
    Khan, Mohammad Nadeem
    Hajri, Amira K.
    Elmasry, Yasser
    Mahariq, Ibrahim
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2024, 190 : 1562 - 1574
  • [22] Accounting for the variable nature of heat loads in optimizing cogeneration combined heat and power plants
    A. M. Kler
    Yu. M. Potanina
    A. S. Maximov
    Thermal Engineering, 2012, 59 (7) : 550 - 556
  • [23] Use of Combined Cogeneration–Thermal Pumping Plants for Municipal Heat Power Engineering and Heat Technologies
    Yu. F. Snezhkin
    B. D. Bileka
    Journal of Engineering Physics and Thermophysics, 2020, 93 : 376 - 383
  • [24] TOTAL ENERGY (COMBINED HEAT AND POWER)
    VOYSEY, RG
    JOURNAL OF THE INSTITUTE OF FUEL, 1967, 40 (318): : 311 - &
  • [25] Combined heat & power: Recycling energy
    Casten, TR
    POWER ENGINEERING, 2003, 107 (09) : 26 - +
  • [26] Energy savings and maintenance optimization through the implementation of GESTENSIS energy management system
    Macarulla, M.
    Casals, M.
    Gangolells, M.
    Tejedor, B.
    EWORK AND EBUSINESS IN ARCHITECTURE, ENGINEERING AND CONSTRUCTION, 2016, : 561 - 566
  • [27] Reduced cogeneration feasible operting region for combined heat and power scheduling problems
    Algie, C
    Wong, KP
    FIFTH INTERNATIONAL CONFERENCE ON POWER SYSTEM MANAGEMENT AND CONTROL, 2002, (488): : 323 - 328
  • [28] Risk Identification in Cogeneration (Combined Heat and Power) Projects: A Polish Case Study
    Rzempala, Joanna
    Borkowski, Daniel
    Rzempala, Artur Piotr
    ENERGIES, 2022, 15 (01)
  • [29] INDUSTRIAL COMBINED HEAT AND POWER - INVESTMENT, SAVINGS AND DECISION-MAKING
    GURNEY, JD
    HYDE, RGF
    PICKERING, SJ
    SHUTE, M
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 1988, 202 (01) : 23 - 37
  • [30] Analysis of energy availability coefficient in heat, power and gas cogeneration system
    Institute of Energy Engineering, Dalian University of Technology, Dalian 116024, China
    Huagong Xuebao, 2006, 11 (2727-2730):