Implantable cardioverter-defibrillator and wait-list outcomes in pediatric patients awaiting heart transplantation

被引:9
|
作者
El-Assaad, Iqbal [1 ]
Al-Kindi, Sadeer G. [2 ]
Oliveira, Guilherme H. [2 ]
Boyle, Gerard J. [3 ]
Aziz, Peter F. [3 ]
机构
[1] Cleveland Clin, Dept Pediat, Cleveland Clin Childrens, Lerner Coll Med, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Adv Heart Failure Ctr, Harrington Heart & Vasc Inst, Univ Hosp Case Med Ctr, Cleveland, OH 44106 USA
[3] Cleveland Clin, Div Pediat Cardiol, Cleveland Clin Childrens, Lerner Coll Med, Cleveland, OH 44195 USA
关键词
Pediatric; Heart transplant; Sudden cardiac death; Implantable cardioverter-defibrillator; SUDDEN CARDIAC DEATH; THERAPY; REGISTRY; FAILURE; GUIDELINES; AMIODARONE; SURVIVAL; CHILDREN; DISEASE;
D O I
10.1016/j.hrthm.2015.07.036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Implantable cardioverter-defibrillators (ICDs) reduce the incidence of sudden cardiac death (SCD) in adults with end-stage heart failure; however, their efficacy in pediatric patients awaiting heart transplantation is not well established. OBJECTIVES This study sought to investigate the role of ICDs in preventing SCD and waiting list mortality as well as to determine risk factors for SCD in pediatric patients listed for heart transplantation. METHODS We queried the United Network for Organ Sharing database for all pediatric patients (age <= 18 years) listed for heart transplantation (2005-2014). The Cox proportional hazards model was used to identify risk factors for SCD and all-cause mortality. RESULTS A total of 5072 mostly White (55%) male (55%) patients (mean age 6.2 +/- 6.5 years) were identified, of whom 426 (8.3%) had ICD at listing. At 6 months, 65% underwent heart transplantation, 15% died (4% died of SCD), and 200/0 were alive. In a multivariable model, United Network for Organ Sharing status 1B (hazard ratio [HR] 0.52; 95% confidence interval [CI] 0.29-0.95; P = .03), myocarditis (HR 0.19; 95% CI 0.05-0.77; P = .02), restrictive cardiomyopathy (HR 0.19; 95% CI 0.05-0.76; P = .02), and dilated cardiomyopathy (HR 0.32; 95% CI 0.20-0.52; P < .001) were associated with lower SCD risk, while younger age at listing (HR 0.94 per year; 95% CI 0.90-0.98; P = .003) was associated with higher SCD risk. ICD at listing was not associated with reduced SCD (P = .12), all-cause mortality, or delisting (P = .57). CONCLUSION In pediatric patients listed for heart transplantation, the risk of SCD remains low and does not differ between patients with and without an ICD at listing.
引用
收藏
页码:2443 / 2448
页数:6
相关论文
共 50 条
  • [21] Incidence of and predictors for appropriate implantable cardioverter-defibrillator therapy in patients with a secondary preventive implantable cardioverter-defibrillator indication
    Schaer, Beat
    Kuehne, Michael
    Reichlin, Tobias
    Osswald, Stefan
    Sticherling, Christian
    EUROPACE, 2016, 18 (02): : 227 - 231
  • [22] Implantable cardioverter-defibrillator implantation as a bridge to cardiac transplantation
    Da Rosa, Michael R.
    Sapp, John L.
    Howlett, Jonathan G.
    Falkenham, Alec
    Legare, Jean-Francois
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (12): : 1336 - 1339
  • [23] Prediction of atrial fibrillation in patients with an implantable cardioverter-defibrillator and heart failure
    Bertini, Matteo
    Borleffs, C. Jan Willem
    Delgado, Victoria
    Ng, Arnold C. T.
    Piers, Sebastiaan R. D.
    Shanks, Miriam
    Antoni, M. Louisa
    Biffi, Mauro
    Boriani, Giuseppe
    Schalij, Martin J.
    Bax, Jeroen J.
    Van de Veire, Nico R. L.
    EUROPEAN JOURNAL OF HEART FAILURE, 2010, 12 (10) : 1101 - 1110
  • [24] Exercise Training and Implantable Cardioverter-Defibrillator Shocks in Patients With Heart Failure
    Piccini, Jonathan P.
    Hellkamp, Anne S.
    Whellan, David J.
    Ellis, Stephen J.
    Keteyian, Steven J.
    Kraus, William E.
    Hernandez, Adrian F.
    Daubert, James P.
    Piña, Ileana L.
    O'Connor, Christopher M.
    JACC-HEART FAILURE, 2013, 1 (02) : 142 - 148
  • [25] Stroke after implantable cardioverter-defibrillator shocks in patients with heart failure
    Dyrbus, Maciej
    Pyka, Lukasz
    Kurek, Anna
    Niedziela, Jacek T.
    Adamowicz-Czoch, Elzbieta
    Ostrega, Mateusz
    Sokola, Katarzyna
    Pres, Damian
    Gasior, Mariusz
    Tajstra, Mateusz
    POLISH HEART JOURNAL-KARDIOLOGIA POLSKA, 2024, 82 (03): : 321 - 323
  • [26] Effect of malnutrition on outcomes of patients hospitalized for implantable cardioverter-defibrillator implantation
    Asemota, Iriagbonse Rotimi
    Shaka, Hafeez
    Akuna, Emmanuel
    Edigin, Ehizogie
    Adeoti, Oluwatomi
    HEART RHYTHM, 2022, 19 (05) : 858 - 859
  • [27] Electrical storm in patients with implantable cardioverter-defibrillator
    Mitrega, Katarzyna
    Sredniawa, Beata
    Kowalski, Oskar
    Lenarczyk, Radoslaw
    Musialik-Lydka, Agata
    Kalarus, Zbigniew
    KARDIOLOGIA POLSKA, 2013, 71 (02) : 198 - 201
  • [28] Electrical storm in patients with implantable cardioverter-defibrillator
    Fernandez, G.
    Maid, G. M.
    Albaca, G. A.
    Constantin, I. C.
    EUROPEAN HEART JOURNAL, 2018, 39 : 215 - 215
  • [29] Implantable cardioverter-defibrillator treatment and resynchronisation in heart failure
    Linde, C
    HEART, 2004, 90 (02) : 231 - 234
  • [30] Implantable cardioverter-defibrillator therapy in congenital heart disease
    McLeod, Christopher J.
    Kapa, Suraj
    Asirvatham, Samuel J.
    EXPERT REVIEW OF MEDICAL DEVICES, 2010, 7 (01) : 1 - 3