Shear behavior of post-tensioned FRP-reinforced concrete slabs under static and fatigue loading

被引:12
|
作者
Noel, Martin [1 ]
Soudki, Khaled [1 ]
机构
[1] Univ Waterloo, Dept Civil & Environm Engn, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Fiber reinforced polymer; Post tensioning; Concrete slabs; Ultimate strength; Concrete bridges; Prestressed concrete; Reinforced concrete; Fatigue tests; POLYMER COMPOSITE BARS; BRIDGE STRIPS; STRENGTH; PERFORMANCE;
D O I
10.1016/j.conbuildmat.2014.07.066
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A reinforcement system for short span concrete slab bridges combining post-tensioned carbon FRP (CFRP) tendons with non-prestressed glass FRP (GFRP) reinforcement can limit the stresses in the GFRP bars to significantly improve fatigue performance. Despite this, the failure mode may be governed by shear and conventional stirrups are, in general, not practical for the construction of slab bridges; therefore the use of innovative shear reinforcement methods is required. Twenty-five FRP-post-tensioned slabs with various types of FRP shear reinforcement were tested under static or fatigue loading. The main variables included the size, shape and type of FRP shear reinforcement used. Fatigue shear strengths at one million cycles were typically in the range of 50-60% of the ultimate static load capacity. Double-headed shear bars were found to be an excellent solution for the shear reinforcement of shallow concrete members which were easy to install and provided high load capacities and good fatigue performance. The fatigue shear strengths of members with anchored shear reinforcement were conservatively predicted using the simplified modified compression field theory, accounting for the change in concrete tensile strength under fatigue loading. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:186 / 195
页数:10
相关论文
共 50 条
  • [21] Finite Element Modeling of Post-Tensioned Two-Way Concrete Slabs under Flexural Loading
    Abdul-Razzaq, Khattab S.
    Mohammed, Abbas H.
    Mohammedali, Taha K.
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2018, 4 (01): : 1 - 10
  • [22] Analytical model to predict punching shear strength of FRP-reinforced concrete flat slabs
    Theodorakopoulos, Dimitrios D.
    Swamy, Narayan
    ACI STRUCTURAL JOURNAL, 2007, 104 (03) : 257 - 266
  • [23] Shear Strength of Reinforced Concrete Columns with External Post-Tensioned Clamps
    Rincon, Julian D.
    Chen, Yu-Mei
    Pujol, Santiago
    Puranam, Aishwarya Y.
    Hwang, Shyh-Jiann
    ACI STRUCTURAL JOURNAL, 2024, 121 (02) : 111 - 125
  • [24] SHEAR AND MOMENT TRANSFER IN POST-TENSIONED FLAT SLABS
    CLARK, BE
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 1-DESIGN AND CONSTRUCTION, 1979, 66 (NOV): : 679 - 687
  • [25] Using an Alternative Method of Analysis to Evaluate Punching Shear Capacity in Existing Post-Tensioned Shear Reinforced Concrete Floor Slabs
    Kritzler, R. W.
    Guedelhoefer, O. C.
    Lammert, B. T.
    Macicak, W. J.
    Structures Congress 2015, 2015, : 1052 - 1064
  • [26] Effect of different loading rates on the fracture behavior of FRP-reinforced concrete
    Liu, Jueding
    Fan, Xiangqian
    Wang, Tao
    Qu, Chiyu
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2023, 46 (12) : 4743 - 4759
  • [27] Fire tests on bonded post-tensioned concrete slabs
    Bailey, Colin G.
    Ellobody, Ehab
    ENGINEERING STRUCTURES, 2009, 31 (03) : 686 - 696
  • [28] Optimization of post-tensioned concrete slabs for minimum cost
    Zelickman, Yakov
    Amir, Oded
    Engineering Structures, 2022, 259
  • [29] Impact behavior of rehabilitated post-tensioned slabs previously damaged by impact loading
    Jahami, A.
    Temsah, Y.
    Khatib, J.
    Baalbaki, O.
    Darwiche, M.
    Chaaban, S.
    MAGAZINE OF CIVIL ENGINEERING, 2020, 93 (01): : 134 - 146
  • [30] Modelling of bonded post-tensioned concrete slabs in fire
    Ellobody, E. A. M.
    Bailey, C. G.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2008, 161 (06) : 311 - 323