Objective assessment of inflammation after cataract surgery: Comparison of 3 similar intraocular lens models

被引:15
|
作者
Monnet, Dominique [1 ]
Tepenier, Laure [1 ]
Brezin, Antoine P. [1 ]
机构
[1] Univ Paris 05, Hop Cochin, AP HP, Serv Ophtalmol, F-75014 Paris, France
来源
关键词
SURGICAL FINDINGS; CHILDREN; FLARE; EYES;
D O I
10.1016/j.jcrs.2008.12.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare postoperative inflammation in patients receiving 1 of 3 AcrySof intraocular lenses (IOLs): MA60AC (Group 1), SA60AT (Group 2), or SN60AT (Group 3). SETTING: Service d'Ophtalmologie, Universite Paris Descartes Hopital Cochin, Paris, France. METHODS: This prospective randomized 3-month study included eyes that received 1 of the 3 IOL models with standard surgery and postoperative care. Anterior chamber cells were assessed at the slitlamp and anterior chamber flare values, with a Kowa 500 flare meter. RESULTS: Fifty-nine patients (59 eyes) with a mean age of 72.7 years were evaluated. Group 1 and Group 2 comprised 20 eyes each and Group 3, 19 eyes. No eye had anterior chamber cells at baseline. In all 3 groups, the presence of anterior chamber cells was highest 1 week postoperatively and generally decreased at subsequent visits, with no statistically significant differences between IOL groups at 1 week (P = .2655), 1 month (P = .073), or 3 months (P = .5766). A similar proportion of eyes in each IOL group had residual cells in the anterior chamber at 3 months; the cells were not clinically significant. In all groups, the mean flare values were low (<11 photons/ms) at baseline (P = .4522) and statistically similar between groups at each subsequent visit (P >=.2801). There were no adverse events. CONCLUSION: The 3 IOLs models, including the blue light-filtering model, had similar anterior chamber cells and flare values over a 3-month period, showing the lack of difference in inflammation induced by cataract surgery with implantation of the 3 similar IOL models.
引用
收藏
页码:677 / 681
页数:5
相关论文
共 50 条
  • [11] Metaanalysis of cataract development after phakic intraocular lens surgery
    Chen, Li-Ju
    Chang, Yun-Jau
    Kuo, Jonathan C.
    Rajagopal, Rama
    Azar, Dimitri T.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (07): : 1181 - 1200
  • [12] Determinants of intraocular lens tilt and decentration after cataract surgery
    Gu, Xiaoxun
    Chen, Xiaoyun
    Yang, Guangyao
    Wang, Wei
    Xiao, Wei
    Jin, Guangming
    Wang, Lanhua
    Dai, Ye
    Ruan, Xiaoting
    Liu, Zhenzhen
    Luo, Lixia
    Liu, Yizhi
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (15)
  • [13] Pseudoexfoliation Material Accumulation on Intraocular Lens after Cataract Surgery
    Salman, Ilknur Akyol
    Eurasian Journal of Medicine, 2016, 48 (03): : 233 - 233
  • [14] Metaanalysis of cataract after phakic intraocular lens surgery REPLY
    Azar, Dimitri T.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11): : 1819 - 1819
  • [15] Intraocular lens employed for cataract surgery
    Roszkowska, A. M.
    Torrisi, L.
    PLASMA PHYSICS BY LASER AND APPLICATIONS 2013 CONFERENCE (PPLA2013), 2014, 508
  • [16] Effect of heparin coating of a foldable intraocular lens on inflammation and capsular bag performance after cataract surgery
    Maedel, Sophie
    Hirnschall, Nino
    Chen, Yen-An
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (12): : 1810 - 1817
  • [17] Flare-cell meter measurement of inflammation after uneventful cataract surgery with intraocular lens implantation
    Alio, JL
    Sayans, JA
    Chipont, E
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (06): : 935 - 939
  • [18] Comparison of the accuracy of intraocular lens power calculations for cataract surgery in eyes after phototherapeutic keratectomy
    Yaguchi, Yukari
    Negishi, Kazuno
    Saiki, Megumi
    Torii, Hidemasa
    Tsubota, Kazuo
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2016, 60 (05) : 365 - 372
  • [19] Comparison of the Visual Outcomes after Cataract Surgery with Implantation of a Bifocal and Trifocal Diffractive Intraocular Lens
    Yu, Sung
    Kim, Yong Il
    Ha, Sang Won
    Lee, Gwang Ja
    Lee, Kyoo Won
    Park, Young Jeung
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (03): : 405 - 412
  • [20] Comparison of the accuracy of intraocular lens power calculations for cataract surgery in eyes after phototherapeutic keratectomy
    Yukari Yaguchi
    Kazuno Negishi
    Megumi Saiki
    Hidemasa Torii
    Kazuo Tsubota
    Japanese Journal of Ophthalmology, 2016, 60 : 365 - 372