New horizons in sequential injection kinetic analysis

被引:7
|
作者
van Staden, JF [1 ]
Stefan, RI [1 ]
机构
[1] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
关键词
kinetic; sequential injection analysis; simultaneous analyses;
D O I
10.1007/s00216-002-1441-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The need to measure several quantities rapidly in the same sample has prompted the development of automated methods of analysis that in both the continuous and discontinuous modes offer the possibility of simultaneous determinations. The application of pH gradients and differential kinetic determinations dominate the simultaneous determination of two or more closely related species in mixtures without prior separation. Various options enable use of kinetic-based measurements for the simultaneous determination of different analytes in flow systems. Some possible general reactions are given and discussed. The scope of sequential injection kinetic analysis is illustrated with examples.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 50 条
  • [41] Spectrophotometric determination of purine alkaloids by flow injection and sequential injection analysis
    L. K. Shpigun
    E. Yu. Andryukhina
    Ya. V. Shushenachev
    Journal of Analytical Chemistry, 2015, 70 : 926 - 935
  • [42] Spectrophotometric determination of purine alkaloids by flow injection and sequential injection analysis
    Shpigun, L. K.
    Andryukhina, E. Yu.
    Shushenachev, Ya. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (08) : 926 - 935
  • [43] Simple convenient method for measuring injection volumes in flow injection and sequential injection analysis
    vanStaden, JF
    Malan, D
    ANALYTICAL COMMUNICATIONS, 1996, 33 (09): : 339 - 341
  • [44] SEQUENTIAL INJECTION-ANALYSIS FOR ELECTROCHEMICAL MEASUREMENTS AND PROCESS ANALYSIS
    CHRISTIAN, GD
    ANALYST, 1994, 119 (11) : 2309 - 2314
  • [46] New generation of sequential injection chromatography: Great enhancement of capabilities of separation using flow analysis
    Chocholous, Petr
    Satinsky, Dalibor
    Solich, Petr
    TALANTA, 2019, 204 : 272 - 277
  • [47] Absorptiometric Determination of Chromium (VI) by Gradient Sandwich Injection/Sequential Injection Analysis
    Okada, Katsuhide
    Akiba, Masanori
    Higuchi, Keiro
    Motomizu, Shoji
    Suzuki, Yasutada
    Furushou, Yoshiaki
    BUNSEKI KAGAKU, 2024, 73 (09) : 531 - 538
  • [48] Sequential injection lab-on-valve: the third generation of flow injection analysis
    Wang, JH
    Hansen, EH
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (04) : 225 - 231
  • [49] Screening of conditions controlling spectrophotometric sequential injection analysis
    Abubakr M Idris
    Chemistry Central Journal, 5
  • [50] Evaluation of the activity of β-glucosidase in solution by sequential injection analysis
    Pilar Canizares-Macias, Maria
    Ruben Carrillo-Medrano, Ulises
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248