Free-breathing cine imaging with motion-corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS)

被引:23
|
作者
Zhou, Ruixi [1 ]
Yang, Yang [2 ,3 ,4 ]
Mathew, Roshin C. [2 ,5 ]
Mugler, John P., III [1 ,2 ,5 ]
Weller, Daniel S. [6 ]
Kramer, Christopher M. [2 ,5 ]
Ahmed, Abdul Haseeb [7 ]
Jacob, Mathews [7 ]
Salerno, Michael [2 ,5 ]
机构
[1] Univ Virginia Hlth Syst, Dept Biomed Engn, Charlottesville, VA USA
[2] Univ Virginia Hlth Syst, Cardiovasc Div, Dept Med, Charlottesville, VA USA
[3] Icahn Sch Med Mt Sinai, Translat & Mol Imaging Inst, New York, NY 10029 USA
[4] Icahn Sch Med Mt Sinai, Dept Radiol, New York, NY 10029 USA
[5] Univ Virginia Hlth Syst, Radiol & Med Imaging, Charlottesville, VA USA
[6] Univ Virginia, Dept Elect & Comp Engn, Charlottesville, VA USA
[7] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
关键词
cardiac MRI; golden angle; low-rank and sparse; motion correction; self-gating; spiral trajectory; STATE FREE PRECESSION; ACCELERATED DYNAMIC MRI; HEART CORONARY MRA; WHOLE-HEART; MAGNETIC-RESONANCE; RADIAL SSFP; INTERFERENCE; COMPENSATION; SUPPRESSION; SPARSITY;
D O I
10.1002/mrm.27763
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a continuous-acquisition cardiac self-gated spiral pulse sequence and a respiratory motion-compensated reconstruction strategy for free-breathing cine imaging. MethodsCine data were acquired continuously on a 3T scanner for 8 seconds per slice without ECG gating or breath-holding, using a golden-angle gradient echo spiral pulse sequence. Cardiac motion information was extracted by applying principal component analysis on the gridded 8 x 8 k-space center data. Respiratory motion was corrected by rigid registration on each heartbeat. Images were reconstructed using a low-rank and sparse (L+S) technique. This strategy was evaluated in 37 healthy subjects and 8 subjects undergoing clinical cardiac MR studies. Image quality was scored (1-5 scale) in a blinded fashion by 2 experienced cardiologists. In 13 subjects with whole-heart coverage, left ventricular ejection fraction (LVEF) from SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS) was compared to that from a standard ECG-gated breath-hold balanced steady-state free precession (bSSFP) cine sequence. ResultsThe self-gated signal was successfully extracted in all cases and demonstrated close agreement with the acquired ECG signal (mean bias, -0.22 ms). The mean image score across all subjects was 4.0 for reconstruction using the L+S model. There was good agreement between the LVEF derived from SPARCS and the gold-standard bSSFP technique. ConclusionSPARCS successfully images cardiac function without the need for ECG gating or breath-holding. With an 8-second data acquisition per slice, whole-heart cine images with clinically acceptable spatial and temporal resolution and image quality can be acquired in <90 seconds of free-breathing acquisition.
引用
收藏
页码:706 / 720
页数:15
相关论文
共 50 条
  • [31] Advancing Free-Breathing Cardiac Cine MRI: Retrospective Respiratory Motion Correction Via Kspace-and-Image Guided Diffusion Model
    Guo, Hongming
    Huang, Ziqing
    Yuan, Qian
    Song, Hanbo
    Liu, Zhiyan
    Feng, Xianzhao
    Liu, Anqi
    Liu, Min
    Li, Ke
    Zhou, Ruixi
    ARTIFICIAL NEURAL NETWORKS AND MACHINE LEARNING-ICANN 2024, PT VIII, 2024, 15023 : 189 - 202
  • [32] Free-breathing cardiac cine MRI with compressed sensing real-time imaging and retrospective motion correction: clinical feasibility and validation
    Lu Lin
    Yanyu Li
    Jian Wang
    Likun Cao
    Yajing Liu
    Jianing Pang
    Jing An
    Zhengyu Jin
    Yining Wang
    European Radiology, 2023, 33 : 2289 - 2300
  • [33] Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation
    Moghari, Mehdi H.
    Barthur, Ashita
    Amaral, Maria E.
    Geva, Tal
    Powell, Andrew J.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 181 - 189
  • [34] Free-breathing cardiac cine MRI with compressed sensing real-time imaging and retrospective motion correction: clinical feasibility and validation
    Lin, Lu
    Li, Yanyu
    Wang, Jian
    Cao, Likun
    Liu, Yajing
    Pang, Jianing
    An, Jing
    Jin, Zhengyu
    Wang, Yining
    EUROPEAN RADIOLOGY, 2023, 33 (04) : 2289 - 2300
  • [35] Free-breathing 3D cardiac T-1 mapping with transmit B-1 correction at 3T
    Han, Paul Kyu
    Marin, Thibault
    Djebra, Yanis
    Landes, Vanessa
    Zhuo, Yue
    El Fakhri, Georges
    Ma, Chao
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1832 - 1845
  • [36] Respiratory Motion-Resolved Compressed Sensing Reconstruction of Free-Breathing Radial Acquisition for Dynamic Liver Magnetic Resonance Imaging
    Chandarana, Hersh
    Feng, Li
    Ream, Justin
    Wang, Annie
    Babb, James S.
    Block, Kai Tobias
    Sodickson, Daniel K.
    Otazo, Ricardo
    INVESTIGATIVE RADIOLOGY, 2015, 50 (11) : 749 - 756
  • [37] Free-breathing abdominal chemical exchange saturation transfer imaging using water presaturation and respiratory gating at 3.0 T
    Chen, Zhensen
    Liu, Chuyu
    Wang, Yishi
    Guo, Rui
    Chen, Weibo
    Wang, He
    Song, Xiaolei
    NMR IN BIOMEDICINE, 2024, 37 (08)
  • [38] Retrospective motion correction through multi-average k-space data elimination (REMAKE) for free-breathing cardiac cine imaging
    Neofytou, Alexander Paul
    Neji, Radhouene
    Kowalik, Grzegorz Tomasz
    Mooiweer, Ronald
    Wong, James
    Fotaki, Anastasia
    Ferreira, Joana
    Evans, Carl
    Bosio, Filippo
    Mughal, Nabila
    Razavi, Reza
    Pushparajah, Kuberan
    Roujol, Sebastien
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (06) : 2242 - 2254
  • [39] A new compressed sensing cine cardiac MRI sequence with free-breathing real-time acquisition and fully automated motion-correction: A comprehensive evaluation
    Longere, Benjamin
    Abassebay, Neelem
    Gkizas, Christos
    Hennicaux, Justin
    Simeone, Arianna
    Musso, Aimee Rodriguez
    Carpentier, Paul
    Coisne, Augustin
    Pang, Jianing
    Schmidt, Michaela
    Toupin, Solenn
    Montaigne, David
    Pontana, Francois
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (11) : 538 - 546
  • [40] Nonlinear profile order for 3D hybrid radial acquisition applied to self-gated free-breathing cardiac cine MRI
    Yanchun Zhu
    Shuo Li
    Jie Yang
    Rongmao Li
    Zhicheng Zhang
    Shaode Yu
    Yaoqin Xie
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)