Free-breathing cine imaging with motion-corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS)

被引:23
|
作者
Zhou, Ruixi [1 ]
Yang, Yang [2 ,3 ,4 ]
Mathew, Roshin C. [2 ,5 ]
Mugler, John P., III [1 ,2 ,5 ]
Weller, Daniel S. [6 ]
Kramer, Christopher M. [2 ,5 ]
Ahmed, Abdul Haseeb [7 ]
Jacob, Mathews [7 ]
Salerno, Michael [2 ,5 ]
机构
[1] Univ Virginia Hlth Syst, Dept Biomed Engn, Charlottesville, VA USA
[2] Univ Virginia Hlth Syst, Cardiovasc Div, Dept Med, Charlottesville, VA USA
[3] Icahn Sch Med Mt Sinai, Translat & Mol Imaging Inst, New York, NY 10029 USA
[4] Icahn Sch Med Mt Sinai, Dept Radiol, New York, NY 10029 USA
[5] Univ Virginia Hlth Syst, Radiol & Med Imaging, Charlottesville, VA USA
[6] Univ Virginia, Dept Elect & Comp Engn, Charlottesville, VA USA
[7] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
关键词
cardiac MRI; golden angle; low-rank and sparse; motion correction; self-gating; spiral trajectory; STATE FREE PRECESSION; ACCELERATED DYNAMIC MRI; HEART CORONARY MRA; WHOLE-HEART; MAGNETIC-RESONANCE; RADIAL SSFP; INTERFERENCE; COMPENSATION; SUPPRESSION; SPARSITY;
D O I
10.1002/mrm.27763
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a continuous-acquisition cardiac self-gated spiral pulse sequence and a respiratory motion-compensated reconstruction strategy for free-breathing cine imaging. MethodsCine data were acquired continuously on a 3T scanner for 8 seconds per slice without ECG gating or breath-holding, using a golden-angle gradient echo spiral pulse sequence. Cardiac motion information was extracted by applying principal component analysis on the gridded 8 x 8 k-space center data. Respiratory motion was corrected by rigid registration on each heartbeat. Images were reconstructed using a low-rank and sparse (L+S) technique. This strategy was evaluated in 37 healthy subjects and 8 subjects undergoing clinical cardiac MR studies. Image quality was scored (1-5 scale) in a blinded fashion by 2 experienced cardiologists. In 13 subjects with whole-heart coverage, left ventricular ejection fraction (LVEF) from SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS) was compared to that from a standard ECG-gated breath-hold balanced steady-state free precession (bSSFP) cine sequence. ResultsThe self-gated signal was successfully extracted in all cases and demonstrated close agreement with the acquired ECG signal (mean bias, -0.22 ms). The mean image score across all subjects was 4.0 for reconstruction using the L+S model. There was good agreement between the LVEF derived from SPARCS and the gold-standard bSSFP technique. ConclusionSPARCS successfully images cardiac function without the need for ECG gating or breath-holding. With an 8-second data acquisition per slice, whole-heart cine images with clinically acceptable spatial and temporal resolution and image quality can be acquired in <90 seconds of free-breathing acquisition.
引用
收藏
页码:706 / 720
页数:15
相关论文
共 50 条
  • [1] Preliminary investigation of respiratory self-gating for free-breathing segmented cine MRI
    Larson, AC
    Kellman, P
    Arai, A
    Hirsch, GA
    McVeigh, E
    Li, DB
    Simonetti, OP
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) : 159 - 168
  • [2] The accuracy and effectiveness of self-gating signals in free-breathing 3D cardiac cine MRI
    Shuo Li
    Yanchun Zhu
    Jie Yang
    Yaoqin Xie
    Song Gao
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [3] Accuracy and effectiveness of self-gating signals in free-breathing three-dimensional cardiac cine magnetic resonance imaging
    李硕
    王磊
    朱艳春
    杨洁
    谢耀钦
    付楠
    王乙
    高嵩
    Chinese Physics B, 2016, 25 (12) : 547 - 552
  • [4] Accuracy and effectiveness of self-gating signals in free-breathing three-dimensional cardiac cine magnetic resonance imaging
    Li, Shuo
    Wang, Lei
    Zhu, Yan-Chun
    Yang, Jie
    Xie, Yao-Qin
    Fu, Nan
    Wang, Yi
    Gao, Song
    CHINESE PHYSICS B, 2016, 25 (12)
  • [5] VALIDATION OF CMR-DERIVED LEFT VENTRICULAR STRAIN MEASUREMENTS BY FREE-BREATHING MOTION-CORRECTED CINE IMAGING
    Merlocco, Anthony
    Cross, Russell
    Kellman, Peter
    Xue, Hui
    Hansen, Michael
    Olivieri, Laura
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1448 - 1448
  • [6] Validation of cardiac magnetic-resonance-derived left ventricular strain measurements from free-breathing motion-corrected cine imaging
    Anthony Merlocco
    Russell R. Cross
    Peter Kellman
    Hui Xue
    Laura Olivieri
    Pediatric Radiology, 2019, 49 : 68 - 75
  • [7] Validation of cardiac magnetic-resonance-derived left ventricular strain measurements from free-breathing motion-corrected cine imaging
    Merlocco, Anthony
    Cross, Russell R.
    Kellman, Peter
    Xue, Hui
    Olivieri, Laura
    PEDIATRIC RADIOLOGY, 2019, 49 (01) : 68 - 75
  • [8] Dual excitation flip angle simultaneous cine and T1 mapping using SPiral Acquisition with Respiratory and Cardiac Self-gating (CAT-SPARCS) (vol 86, pg 82, 2021)
    Zhou, Ruixi
    Weller, Daniel S.
    Yang, Yang
    Wang, Junyu
    Jeelani, Haris
    Mugler, John P., III
    Salerno, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (05) : 2880 - 2880
  • [9] Dual-excitation flip-angle simultaneous cine and T1 mapping using spiral acquisition with respiratory and cardiac self-gating
    Zhou, Ruixi
    Weller, Daniel S.
    Yang, Yang
    Wang, Junyu
    Jeelani, Haris
    Mugler, John P.
    Salerno, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (01) : 82 - 96
  • [10] High efficiency free-breathing 3D thoracic aorta vessel wall imaging using self-gating image reconstruction
    Shi, Caiyun
    Liang, Dong
    Wang, Haifeng
    Zhu, Yanjie
    MAGNETIC RESONANCE IMAGING, 2024, 107 : 80 - 87