Image-based modeling of arteriovenous hemodialysis access graft flow

被引:0
|
作者
Schmidt, BR [1 ]
Kim, CB [1 ]
Mohamed, FB [1 ]
Nunes, LW [1 ]
Ahmed, Z [1 ]
Wootton, DM [1 ]
机构
[1] Drexel Univ, Dept Mech Engn, Coll Engn, Philadelphia, PA 19104 USA
关键词
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Thrombosis in an arteriovenous hemodialysis access graft is a major cause of graft failure. Changes in flow features due to increasing resistance at the venous anastomosis may promote the development of thrombosis. A three-dimensional computational fluid dynamics model was developed to analyze flow at the arterial anastomosis of a PTFE brachial-brachial arteriovenous access graft. The geometry was obtained from contrast-enhanced magnetic resonance images. A surface mesh was extracted using Amira software, and the final volume mesh was generated by Tgrid (Fluent, Inc). The simulation was carried out for steady flow conditions using Fluent CFD software with low-Reynolds number k-omega turbulence model. Small areas of recirculation can be seen in the area of the bifurcation, and results show a pressure difference between the proximal artery and the graft that is consistent with reported values.
引用
收藏
页码:69 / 70
页数:2
相关论文
共 50 条
  • [31] Assessment of Use of Arteriovenous Graft vs Arteriovenous Fistula for First-time Permanent Hemodialysis Access
    Hicks, Caitlin W.
    Wang, Peiqi
    Kernodle, Amber
    Lum, Ying W.
    Black, James H., III
    Makary, Martin A.
    JAMA SURGERY, 2019, 154 (09) : 844 - 851
  • [32] Image-based simulation of brain arteriovenous malformation hemodynamics
    Orlowski, Piotr
    Noble, J. Alison
    Ventikos, Nannis
    Byrne, James
    Summers, Paul
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 676 - +
  • [33] Quantification of steal flow on Doppler ultrasound in patients with arteriovenous graft for hemodialysis
    Kang, Kyoungin
    Lee, Jung Ho
    Hwang, Hong Pil
    Kaliannagounder, Vignesh Krishnamoorthi
    Park, Chan Hee
    Kwak, Hyo Sung
    VASCULAR, 2024,
  • [34] Arteriovenous access for chronic Hemodialysis
    Settmacher, U.
    CHIRURG, 2012, 83 (09): : 773 - 774
  • [35] Hemodialysis arteriovenous access: Detection of stenosis and response to treatment by vascular access blood flow
    Schwab, SJ
    Oliver, MJ
    Suhocki, P
    McCann, R
    KIDNEY INTERNATIONAL, 2001, 59 (01) : 358 - 362
  • [36] Amplatzer vascular plug for occlusion or flow reduction of hemodialysis arteriovenous access
    Bourquelot, Pierre
    Karam, Lamisse
    Raynaud, Alain
    Beyssen, Bernard
    Ricco, Jean-Baptiste
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (01) : 260 - 263
  • [37] Image-Based Modeling for Virtual Museum
    Kim, Jin-Mo
    Shin, Do-Kyung
    Ahn, Eun-Young
    MULTIMEDIA, COMPUTER GRAPHICS AND BROADCASTING, PT I, 2011, 262 : 108 - +
  • [38] Media Content Access: Image-Based Filtering
    Khan, Rehan Ullah
    Alkhalifah, Ali
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2018, 9 (03) : 415 - 419
  • [39] Image-Based Procedure for Biostructure Modeling
    Yang, Judy P.
    JOURNAL OF NANOMECHANICS AND MICROMECHANICS, 2014, 4 (03)
  • [40] Image-Based Modeling of the Human Eye
    Francois, Guillaume
    Gautron, Pascal
    Breton, Gaspard
    Bouatouch, Kadi
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2009, 15 (05) : 815 - 827