Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique

被引:12
|
作者
Kim, Jun-Hwee [1 ,2 ]
Kim, Myung-Joon [1 ,2 ]
Kim, Ha Yan [3 ]
Lee, Mi-Jung [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Severance Childrens Hosp, Dept Radiol, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Severance Childrens Hosp, Res Inst Radiol Sci, Seoul 120752, South Korea
[3] Yonsei Univ, Severance Hosp, Biostat Collaborat Unit, Seoul 120752, South Korea
关键词
Pediatric; Computed tomography; Radiation dose; Iterative reconstruction; COMPUTED-TOMOGRAPHY; CARDIAC CT; CHEST CT; ANGIOGRAPHY; EXPOSURE; CHILDREN; SAFIRE; NOISE; ASIR;
D O I
10.1016/j.clinimag.2014.05.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The objective of this study was to compare the radiation dose and image quality of pediatric abdominal computed tomography (CT) using a protocol reconstructed with filtered back projection (FBP) and a protocol with both kVp and mAs modulation and sinogram-affirmed iterative reconstruction (SAFIRE). Materials and methods: We retrospectively reviewed pediatric abdominal CT examinations performed with both kVp and mAs modulation. These raw data were reconstructed with SAFIRE at different strengths from 2 to 4 (SAFIRE groups 2-4). Another set of age/sex-matched pediatric abdominal CT examinations were also reviewed, which were performed during the same period with only mAs modulation and FBP (control group). The radiation dose and image quality were compared between groups. The image quality was objectively evaluated as the noise measured in the liver, aorta, and spleen at the level of the main portal vein and the image quality was subjectively reviewed by two radiologists for diagnostic acceptability using a four-point scale (0: unacceptable; 1: worse than the control group, but acceptable; 2: comparable with the control group; and 3: better than the control group). An independent t test was used in order to compare the radiation dose. An independent t test with Bonferroni correction and generalized estimating equations were used for the comparison of the objective and subjective image quality, respectively. Results: Twenty-nine patients (M:F=19:10; mean age, 10.0 years) were enrolled in each group. The SAFIRE group, using the size-specific dose estimates calculation method showed a 64.2% radiation dose reduction (from 8.1 to 2.9 mGy, P<.05), compared with the results of the control group. The objective image noise of the SAFIRE groups 2 and 3 was comparable to that of the control group. The subjective image quality was the best in SAFIRE group 3 [odds ratio (OR) 3.015, P<.001 when comparing to SAFIRE group 0; OR 1.513, P<.001 when comparing to SAFIRE group 2]. Conclusions: Image acquisition with both kVp and mAs modulation and iterative reconstruction using SAFIRE with strength 3 can preserve the objective and subjective image quality of pediatric abdominal CT scans with less than half the radiation dose. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:710 / 714
页数:5
相关论文
共 50 条
  • [41] Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children
    Haesung Yoon
    Myung-Joon Kim
    Choon-Sik Yoon
    Jiin Choi
    Hyun Joo Shin
    Hyun Gi Kim
    Mi-Jung Lee
    Pediatric Radiology, 2015, 45 : 337 - 344
  • [42] Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children
    Yoon, Haesung
    Kim, Myung-Joon
    Yoon, Choon-Sik
    Choi, Jiin
    Shin, Hyun Joo
    Kim, Hyun Gi
    Lee, Mi-Jung
    PEDIATRIC RADIOLOGY, 2015, 45 (03) : 337 - 344
  • [43] Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose
    Hyun-Hae Cho
    So Mi Lee
    Sun Kyoung You
    Pediatric Radiology, 2020, 50 : 242 - 251
  • [44] Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose
    Cho, Hyun-Hae
    Lee, So Mi
    You, Sun Kyoung
    PEDIATRIC RADIOLOGY, 2020, 50 (02) : 242 - 251
  • [45] Indirect CT Venography at 80 kVp with Sinogram-Affirmed Iterative Reconstruction Compared to 120 kVp with Filtered Back Projection: Assessment of Image Quality and Radiation Dose
    Song, Inyoung
    Yi, Jeong Geun
    Park, Jeong Hee
    Ko, Sung Min
    PLOS ONE, 2016, 11 (09):
  • [46] Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction
    Nagayama, Yasunori
    Oda, Seitaro
    Nakaura, Takeshi
    Tsuji, Akinori
    Urata, Joji
    Furusawa, Mitsuhiro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Kidoh, Masafumi
    Yamashita, Yasuyuki
    RADIOGRAPHICS, 2018, 38 (05) : 1421 - +
  • [47] Cerebral bone subtraction CT angiography using 80 kVp and sinogram-affirmed iterative reconstruction: contrast medium and radiation dose reduction with improvement of image quality
    Nagayama, Yasunori
    Nakaura, Takeshi
    Tsuji, Akinori
    Urata, Joji
    Furusawa, Mitsuhiro
    Yuki, Hideaki
    Hirarta, Kenichiro
    Oda, Seitaro
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Yamashita, Yasuyuki
    NEURORADIOLOGY, 2017, 59 (02) : 127 - 134
  • [48] Cerebral bone subtraction CT angiography using 80 kVp and sinogram-affirmed iterative reconstruction: contrast medium and radiation dose reduction with improvement of image quality
    Yasunori Nagayama
    Takeshi Nakaura
    Akinori Tsuji
    Joji Urata
    Mitsuhiro Furusawa
    Hideaki Yuki
    Kenichiro Hirarta
    Seitaro Oda
    Masafumi Kidoh
    Daisuke Utsunomiya
    Yasuyuki Yamashita
    Neuroradiology, 2017, 59 : 127 - 134
  • [49] Evaluation of image quality and radiation dose by adaptive statistical iterative reconstruction technique level for chest CT examination
    Hong, Sun Suk
    Lee, Jong-Woong
    Seo, Jeong Beom
    Jung, Jae-Eun
    Choi, Jiwon
    Kweon, Dae Cheol
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (02) : 163 - 171
  • [50] Radiation Dose Reduction in Pediatric Body CT Using Iterative Reconstruction and a Novel Image-Based Denoising Method
    Yu, Lifeng
    Fletcher, Joel G.
    Shiung, Maria
    Thomas, Kristen B.
    Matsumoto, Jane M.
    Zingula, Shannon N.
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (05) : 1026 - 1037