In Vivo Contact Force Analysis and Correlation With Tissue Impedance During Left Atrial Mapping and Catheter Ablation of Atrial Fibrillation

被引:47
|
作者
Makimoto, Hisaki [1 ]
Lin, Tina [1 ]
Rillig, Andreas [1 ]
Metzner, Andreas [1 ]
Wohlmuth, Peter [2 ]
Arya, Anita [1 ]
Antz, Matthias [1 ]
Mathew, Shibu [1 ]
Deiss, Sebastian [1 ]
Wissner, Erik [1 ]
Rausch, Peter [1 ]
Bardyszewski, Aleksander [1 ]
Kamioka, Masashi [1 ]
Li, Xuping [1 ]
Kuck, Karl-Heinz [1 ]
Ouyang, Feifan [1 ]
Tilz, Roland Richard [1 ]
机构
[1] Asklepios Klin St Georg, Dept Cardiol, D-20099 Hamburg, Germany
[2] Asklepios Klin St Georg, D-20099 Hamburg, Germany
来源
关键词
RADIOFREQUENCY LESION SIZE; PULMONARY VEIN ISOLATION; DOUBLE-LASSO TECHNIQUE; ELECTRODE; TOCCATA;
D O I
10.1161/CIRCEP.113.000556
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The aim of this study was to evaluate in vivo contact force (CF) and the correlation of CF with impedance during left atrial 3-dimensional electroanatomical mapping and ablation. Methods and Results-CF during point-by-point left atrial mapping was assessed in 30 patients undergoing atrial fibrillation ablation. Operators were blinded to the real-time CF data. Data were analyzed according to 11 predefined areas in the left atrial and 6 segments around the ipsilateral pulmonary veins. A total of 3475 mapping and 878 ablation points were analyzed. Median CF during mapping was 14.0g (6.5-26.2; q1-q3), ranging from 5.1g at the ridge to 29.8g at the roof. Median CF at the ridge and mitral isthmus were 5.1g and 6.9g, respectively. Extremely high CF ≥100g was noted in 24 points (0.7%). Median CFs during ablation around the right and left pulmonary veins were 22.8g (12.6-37.9; q1-q3) and 12.3g (6.9-30.2; q1-q3), respectively. The lowest median CFs were recorded at the anterior-superior and anterior- inferior segments of the left pulmonary veins (7.2g and 7.9g). Impedance values during mapping and impedance fall during ablation correlated with the applied CF (R2=0.16; P<0.001 and R2=0.04; P<0.001) although there was significant overlap. Conclusions-Excessively high and low CF values can be observed during left atrial mapping and ablation. The low CF obtained at the mitral isthmus and anterior segments of the left pulmonary veins may explain why reconnection after ablation occurs more frequently at these sites. CF and impedance do correlate; however, the impedance for a given CF ranges widely, limiting its use in clinical practice. © 2013 American Heart Association, Inc.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 50 条
  • [41] Left Atrial Pressure is a Determinant of Catheter Ablation Outcome of Atrial Fibrillation
    Dong, Y. X.
    Jae, K. O.
    Brian, D. P.
    Cha, Y. M.
    Yang, Y. Z.
    CARDIOLOGY, 2010, 117 : 74 - 75
  • [42] Neurological complications after left atrial catheter ablation for atrial fibrillation
    Haeusler, K. G.
    Tebbe, U.
    Willems, S.
    Sprenger, C.
    Kirchhof, P.
    Endres, M.
    Oeff, M.
    NERVENHEILKUNDE, 2012, 31 (11) : 830 - 835
  • [43] Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
    Swaans, Martin J.
    Alipour, Arash
    Rensing, Benno J. W. M.
    Post, Martijn C.
    Boersma, Lucas V. A.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (72):
  • [44] Visualization of the esophagus throughout left atrial catheter ablation for atrial fibrillation
    Yamane, T
    Matsuo, S
    Date, T
    Mochizuki, S
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (01) : 105 - 105
  • [45] Left atrial function and scar after catheter ablation of atrial fibrillation
    Wylie, John V., Jr.
    Peters, Dana C.
    Essebag, Vidal
    Manning, Warren J.
    Josephson, Mark E.
    Hauser, Thomas H.
    HEART RHYTHM, 2008, 5 (05) : 656 - 662
  • [46] Intramural Left Atrial Hematoma Complicating Catheter Ablation for Atrial Fibrillation
    Looi, Jen-Li
    Lee, Alex Pui-Wai
    Chan, Chin-Pang
    Chan, Joseph Yat-Sun
    Chan, Anna Kin-Yin
    Tong, Mable
    Wong, Ka-Tak
    Yu, Cheuk-Man
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (03) : 252 - 252
  • [47] Left Atrial Ejection Force as a Predictor of Outcome After Catheter Ablation in an Early Stage of Atrial Fibrillation
    Kishima, Hideyuki
    Mine, Takanao
    Takahashi, Satoshi
    Ashida, Kenki
    Ishihara, Masaharu
    Masuyama, Tohru
    CIRCULATION, 2017, 136
  • [48] Contact force mapping during catheter ablation for atrial fibrillation: procedural data and one-year follow-up
    Wutzler, Alexander
    Huemer, Martin
    Parwani, Abdul Shokor
    Blaschke, Florian
    Haverkamp, Wilhelm
    Boldt, Leif-Hendrik
    ARCHIVES OF MEDICAL SCIENCE, 2014, 10 (02) : 266 - 272
  • [49] Mapping and ablation of left atrial tachycardias occurring after atrial fibrillation ablation
    Gerstenfeld, Edward P.
    Marchlinski, Francis E.
    HEART RHYTHM, 2007, 4 (03) : S65 - S72
  • [50] Left atrial model reconstruction in atrial fibrillation ablation: reliability of new mapping and complex impedance systems
    Bonso, Aldo
    Fantinel, Mauro
    Scalchi, Giovanna
    Ferrara, Sabrina
    Indiani, Stefano
    Calore, Federico
    Licciardello, Claudia
    EUROPACE, 2017, 19 (11): : 1804 - 1809