Cone beam computed tomography and low-dose multislice computed tomography in orthodontics and dentistry A comparative evaluation on image quality and radiation exposure

被引:0
|
作者
Hofmann, Elisabeth [1 ]
Schmid, Matthias [2 ]
Lell, Michael [3 ,4 ]
Hirschfelder, Ursula [1 ]
机构
[1] Univ Klinikum Erlangen, Dept Orthodont & Orofacial Orthoped, Zahnklin Kieferorthopadie 3, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, D-91054 Erlangen, Germany
[3] Univ Klinikum Erlangen, Dept Radiol, D-91054 Erlangen, Germany
[4] Imaging Sci Inst ISI, Erlangen, Germany
来源
JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE | 2014年 / 75卷 / 05期
关键词
Diagnostic imaging; Radiation dose; Organ dose; Image quality; Dental radiography; CBCT DEVICES; CT; DOSIMETRY; SCANNERS; MSCT; REDUCTION; RADIOLOGY; AGREEMENT; ACCURACY;
D O I
10.1007/s00056-014-0232-x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The goal of the present work was to assess various computed tomography (CT) systems in term of image quality and organ doses, namely five cone-beam CT (CBCT) scanners operated at standard settings and three multislice CT (MSCT) scanners operated at greatly dose-reduced settings. Radiographic volume scans were taken on a complete human cadaveric head specimen and the image quality of each was rated by four experienced examiners according to specific skeletal structures and bone-soft tissue interfaces. Radiation doses were captured by a head-and-neck phantom (Rando; Alderson Research Laboratories). Standard protocols were used for the CBCT scans. For the MSCT scans, tube voltage and current were adjusted to minimize radiation without compromising image quality. Interobserver agreement was close to perfect, with iota coefficients of 0.931 (95 % CI 0.807-0.978) between groups 1 and 2 and 0.959 (95 % CI 0.869-1.000) between groups 1 and 3. Ratings of image quality in terms of skeletal-structure representation were slightly better for the CBCT than the MSCT scanners, although these differences were not statistically significant. The two groups of scanners applied considerably different organ doses: the lowest dose (0.03 mSv) was measured on the bone surface with a CBCT unit (Picasso TrioA (R) from Vatech) and the highest dose (8.30 mSv) in the vicinity of the eye lens with another CBCT unit (3D Accuitomo 170A (R) from J. Morita). The various systems tested offer similar imaging quality but demonstrated distinct differences in organ dose levels. The decision on which approach to take is not between CBCT and MSCT but rather between specific models and parameter settings. If these are optimized, MSCT images providing useful clinical information can be obtained at much reduced levels of radiation. Depending on the model and setting used, MSCT radiation levels may even be lower than during CBCT scans.
引用
收藏
页码:384 / 398
页数:15
相关论文
共 50 条
  • [31] EVALUATION OF THYROID RADIATION DOSE USING CONE BEAM COMPUTED TOMOGRAPHY
    Penteado Setti da Rocha, Anna Silvia
    Aguiar, Guilherme de Mello
    Tulio, Ana Paula
    Ditzel, Alessandra S.
    Filipov, Danielle
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) : 368 - 372
  • [32] Experiences with image quality and radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in pediatric extremity trauma
    Tschauner, Sebastian
    Marterer, Robert
    Nagy, Eszter
    Singer, Georg
    Riccabona, Michael
    Sorantin, Erich
    SKELETAL RADIOLOGY, 2020, 49 (12) : 1939 - 1949
  • [33] Experiences with image quality and radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in pediatric extremity trauma
    Sebastian Tschauner
    Robert Marterer
    Eszter Nagy
    Georg Singer
    Michael Riccabona
    Erich Sorantin
    Skeletal Radiology, 2020, 49 : 1939 - 1949
  • [34] Radiation Exposure of Abdominal Cone Beam Computed Tomography
    Anna M. Sailer
    Geert Willem H. Schurink
    Joachim E. Wildberger
    Rick de Graaf
    Willem H. van Zwam
    Michiel W. de Haan
    Gerrit J. Kemerink
    Cécile R. L. P. N. Jeukens
    CardioVascular and Interventional Radiology, 2015, 38 : 112 - 120
  • [35] Radiation Exposure of Abdominal Cone Beam Computed Tomography
    Sailer, Anna M.
    Schurink, Geert Willem H.
    Wildberger, Joachim E.
    de Graaf, Rick
    van Zwam, Willem H.
    de Haan, Michiel W.
    Kemerink, Gerrit J.
    Jeukens, Cecile R. L. P. N.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (01) : 112 - 120
  • [36] Cone-Beam Computed Tomography and Radiographs in Dentistry: Aspects Related to Radiation Dose
    Coelho Lorenzoni, Diego
    Maria Bolognese, Ana
    Gamba Garib, Daniela
    Ribeiro Guedes, Fabio
    Franzotti Sant'Anna, Eduardo
    INTERNATIONAL JOURNAL OF DENTISTRY, 2012, 2012
  • [37] Understanding and communicating radiation dose and risk from cone beam computed tomography in dentistry
    Aanenson, Jill Weber
    Till, John E.
    Grogan, Helen A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03): : 353 - 360
  • [38] Cone Beam Computed Tomography in Veterinary Dentistry
    Van Thielen, Bert
    Siguenza, Francis
    Hassan, Bassam
    JOURNAL OF VETERINARY DENTISTRY, 2012, 29 (01) : 27 - 34
  • [39] Low-dose computed tomography perceptual image quality assessment
    Lee, Wonkyeong
    Wagner, Fabian
    Galdran, Adrian
    Shi, Yongyi
    Xia, Wenjun
    Wang, Ge
    Mou, Xuanqin
    Ahamed, Md. Atik
    Imran, Abdullah Al Zubaer
    Oh, Ji Eun
    Kim, Kyungsang
    Baek, Jong Tak
    Lee, Dongheon
    Hong, Boohwi
    Tempelman, Philip
    Lyu, Donghang
    Kuiper, Adrian
    van Blokland, Lars
    Calisto, Maria Baldeon
    Hsieh, Scott
    Han, Minah
    Baek, Jongduk
    Maier, Andreas
    Wang, Adam
    Gold, Garry Evan
    Choi, Jang-Hwan
    MEDICAL IMAGE ANALYSIS, 2025, 99
  • [40] Radiation dose and image quality in computed tomography
    Prokop, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (05): : 631 - 636