Cone beam computed tomography and low-dose multislice computed tomography in orthodontics and dentistry A comparative evaluation on image quality and radiation exposure

被引:0
|
作者
Hofmann, Elisabeth [1 ]
Schmid, Matthias [2 ]
Lell, Michael [3 ,4 ]
Hirschfelder, Ursula [1 ]
机构
[1] Univ Klinikum Erlangen, Dept Orthodont & Orofacial Orthoped, Zahnklin Kieferorthopadie 3, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, D-91054 Erlangen, Germany
[3] Univ Klinikum Erlangen, Dept Radiol, D-91054 Erlangen, Germany
[4] Imaging Sci Inst ISI, Erlangen, Germany
关键词
Diagnostic imaging; Radiation dose; Organ dose; Image quality; Dental radiography; CBCT DEVICES; CT; DOSIMETRY; SCANNERS; MSCT; REDUCTION; RADIOLOGY; AGREEMENT; ACCURACY;
D O I
10.1007/s00056-014-0232-x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The goal of the present work was to assess various computed tomography (CT) systems in term of image quality and organ doses, namely five cone-beam CT (CBCT) scanners operated at standard settings and three multislice CT (MSCT) scanners operated at greatly dose-reduced settings. Radiographic volume scans were taken on a complete human cadaveric head specimen and the image quality of each was rated by four experienced examiners according to specific skeletal structures and bone-soft tissue interfaces. Radiation doses were captured by a head-and-neck phantom (Rando; Alderson Research Laboratories). Standard protocols were used for the CBCT scans. For the MSCT scans, tube voltage and current were adjusted to minimize radiation without compromising image quality. Interobserver agreement was close to perfect, with iota coefficients of 0.931 (95 % CI 0.807-0.978) between groups 1 and 2 and 0.959 (95 % CI 0.869-1.000) between groups 1 and 3. Ratings of image quality in terms of skeletal-structure representation were slightly better for the CBCT than the MSCT scanners, although these differences were not statistically significant. The two groups of scanners applied considerably different organ doses: the lowest dose (0.03 mSv) was measured on the bone surface with a CBCT unit (Picasso TrioA (R) from Vatech) and the highest dose (8.30 mSv) in the vicinity of the eye lens with another CBCT unit (3D Accuitomo 170A (R) from J. Morita). The various systems tested offer similar imaging quality but demonstrated distinct differences in organ dose levels. The decision on which approach to take is not between CBCT and MSCT but rather between specific models and parameter settings. If these are optimized, MSCT images providing useful clinical information can be obtained at much reduced levels of radiation. Depending on the model and setting used, MSCT radiation levels may even be lower than during CBCT scans.
引用
收藏
页码:384 / 398
页数:15
相关论文
共 50 条
  • [1] Comparative study of image quality and radiation dose of cone beam and low-dose multislice computed tomography - an in-vitro investigation
    Elisabeth Hofmann
    Matthias Schmid
    Martin Sedlmair
    Rosemarie Banckwitz
    Ursula Hirschfelder
    Michael Lell
    Clinical Oral Investigations, 2014, 18 : 301 - 311
  • [2] Comparative study of image quality and radiation dose of cone beam and low-dose multislice computed tomography - an in-vitro investigation
    Hofmann, Elisabeth
    Schmid, Matthias
    Sedlmair, Martin
    Banckwitz, Rosemarie
    Hirschfelder, Ursula
    Lell, Michael
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (01) : 301 - 311
  • [3] A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging
    De Cock, Jens
    Zanca, Federica
    Canning, John
    Pauwels, Ruben
    Hermans, Robert
    EUROPEAN RADIOLOGY, 2015, 25 (07) : 1891 - 1900
  • [4] A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging
    Jens De Cock
    Federica Zanca
    John Canning
    Ruben Pauwels
    Robert Hermans
    European Radiology, 2015, 25 : 1891 - 1900
  • [5] Evaluation of image quality and radiation dose in kilovoltage cone beam computed tomography
    Pinsaitong, N.
    Asavaphatiboon, S.
    Tangboonduangjit, P.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [6] Cone beam computed tomography for imaging orbital trauma-image quality and radiation dose compared with conventional multislice computed tomography
    Brisco, Jessica
    Fuller, Karen
    Lee, Nicholas
    Andrew, David
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2014, 52 (01): : 76 - 80
  • [7] Dose and Image Quality of Cone-Beam Computed Tomography as Compared With Conventional Multislice Computed Tomography in Abdominal Imaging
    Schegerer, Alexander A.
    Lechel, Ursula
    Ritter, Manuel
    Weisser, Gerald
    Fink, Christian
    Brix, Gunnar
    INVESTIGATIVE RADIOLOGY, 2014, 49 (10) : 675 - 684
  • [8] Evaluation of Radiation Dose and Image Quality for TheVarian Cone Beam Computed Tomography System
    Cheng, H.
    Wu, V.
    Liu, E.
    Kwong, D.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [9] EVALUATION OF RADIATION DOSE AND IMAGE QUALITY FOR THE VARIAN CONE BEAM COMPUTED TOMOGRAPHY SYSTEM
    Cheng, Harry C. Y.
    Wu, Vincent W. C.
    Liu, Eva S. F.
    Kwong, Dora L. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01): : 291 - 300
  • [10] Comparative study of jaws with multislice computed tomography and cone-beam computed tomography
    Carrafiello, G.
    Dizonno, M.
    Colli, V.
    Strocchi, S.
    Taubert, S. Pozzi
    Leonardi, A.
    Giorgianni, A.
    Barresi, M.
    Macchi, A.
    Bracchi, E.
    Conte, L.
    Fugazzola, C.
    RADIOLOGIA MEDICA, 2010, 115 (04): : 600 - 611