A rapid, sensitive HPLC method for the determination of ganciclovir in human plasma and serum

被引:31
|
作者
Chu, F
Kiang, CH
Sung, ML
Huang, B
Reeve, RL
Tarnowski, T
机构
[1] Roche Biosci, Palo Alto, CA 94304 USA
[2] PHARMout Labs Inc, Sunnyvale, CA 94086 USA
[3] Chiron Corp, Emeryville, CA 94608 USA
关键词
ganciclovir; column switching; reverse-phase liquid chromatography; human serum; human plasma;
D O I
10.1016/S0731-7085(99)00161-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for ganciclovir determination in human serum and plasma has been developed and validated. The method has a lower limit of quantification (LLOQ) adequate for sensitive pharmacokinetic studies (≤0.05 μg/ml), has run times of ≤15 min, and uses aliquot volumes adequate for pediatric studies (0.25 ml). In the method, proteinaceous material in serum or plasma is precipitated by trichloroacetic acid. An aliquot of the supernatant is analyzed by HPLC; automated column switching removes late-eluting materials that might interfere with the analyte peak in subsequent runs. Detection and quantification of ganciclovir is by fluorescence (λ(ex)=278 nm; λ(em)=380 nm). The method has a validated range of 0.0400-4.00 μg/ml and an LLOQ of 0.0400 μg/ml. All intra- and inter-assay % C.V. values were <8%; all recoveries (accuracy) were within 7% of nominal values. No interference was observed by mycophenolic acid or its glucuronide metabolite, by AZT, salicylic acid, acetaminophen, ibuprofen, naproxen prednisone, acyclovir, or cyclosporine. Ganciclovir is very stable in the samples and the extract during storage and sample processing. Both serum and plasma methods have been validated for use and have been successfully used to analyze samples from clinical studies. Copyright (C) 1999 Elsevier Science B.V.
引用
收藏
页码:657 / 667
页数:11
相关论文
共 50 条
  • [21] RAPID HPLC DETERMINATION OF BISOPROLOL IN HUMAN PLASMA
    KINTZ, P
    LOHNER, S
    TRACQUI, A
    MANGIN, P
    LUGNIER, A
    CHAUMONT, AJ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 336 (06): : 517 - 517
  • [22] A SELECTIVE AND SENSITIVE METHOD FOR THE DETERMINATION OF PROPAFENON AND METABOLITES IN HUMAN-SERUM BY HPLC
    BEUMAN, G
    BOESTEN, M
    VANDERHEIJDEN, J
    PHARMACEUTISCH WEEKBLAD-SCIENTIFIC EDITION, 1986, 8 (06) : 319 - 319
  • [23] A RAPID AND SENSITIVE METHOD FOR HPLC CHOLESTEROL DETERMINATION IN BILE
    BOCOS, C
    CASTRO, M
    OROZCO, E
    CONTRERAS, JA
    HERRERA, E
    REVISTA ESPANOLA DE FISIOLOGIA, 1992, 48 (03): : 211 - 214
  • [24] A RAPID AND SENSITIVE METHOD FOR SIMULTANEOUS DETERMINATION OF EPINEPHRINE AND NOREPINEPHRINE IN HUMAN PLASMA
    SAITO, H
    WORONKOW, S
    MYERS, B
    JAPANESE CIRCULATION JOURNAL, 1969, 33 (06): : 677 - &
  • [25] RAPID AND SENSITIVE METHOD FOR ERYTHROPOIETIN DETERMINATION IN SERUM
    TANEBE, M
    TESHIMA, S
    HANYU, T
    HAYASHI, Y
    CLINICAL CHEMISTRY, 1992, 38 (09) : 1752 - 1755
  • [26] A sensitive HPLC-MS/MS method for the determination of dolutegravir in human plasma
    Bennetto-Hood, Chantelle
    Tabolt, Glenn
    Savina, Paul
    Acosta, Edward P.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 945 : 225 - 232
  • [27] Sensitive HPLC method for the determination of fluoxetine and norfluoxetine in human plasma with fluorescence detection
    Ertürk, S
    Çetin, SM
    Atmaca, S
    Ersoy, L
    Baktir, G
    THERAPEUTIC DRUG MONITORING, 2005, 27 (01) : 38 - 43
  • [28] Development of a sensitive HPLC method with fluorescence detection for determination of motilin in human plasma
    Karaca, Sakine Atila
    Temel, Tuncer
    Ugur, Duygu Yeniceli
    BIOANALYSIS, 2023, 15 (04) : 219 - 229
  • [29] Simple and sensitive HPLC method for determination of gemfibrozil in human plasma with fluorescence detection
    Kim, CK
    Jae, JP
    Hwang, HR
    Ban, E
    Maeng, JE
    Kim, MK
    Piao, XL
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (03) : 403 - 414
  • [30] Sensitive HPLC-ESI-MS method for the determination of tiotropium in human plasma
    Ding, Li
    Tan, Wenming
    Zhang, Yindi
    Shen, Jianping
    Zhang, Zhengxing
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (05) : 445 - 449