Efficient siesmic analysis of building structures with added viscoelastic dampers

被引:23
|
作者
Lee, DG [1 ]
Hong, S [1 ]
Kim, J [1 ]
机构
[1] Sungkyunkwan Univ, Dept Architectural Engn, Jangan Gu, Suwon 440746, South Korea
关键词
viscoelastic dampers; non-proportional damping; rigid diaphragm; matrix condensation technique;
D O I
10.1016/S0141-0296(02)00058-5
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Conventional analysis methods for building structures with added viscoelastic dampers, such as direct integration, complex mode superposition, and modal strain energy method, were compared, and a procedure based on rigid diaphragm assumption and matrix condensation technique was proposed for application in the preliminary analysis and design stages. The results from the various analysis methods with and without the matrix condensation were compared, in view of both accuracy and efficiency. According to the eigenvalue analysis the major vibration modes were mostly preserved after the matrix condensation. It was also found that the matrix condensation technique applied to dynamic analysis of a structure with added viscoelastic dampers provided quite accurate results in significantly reduced time, regardless of the plan shape and the location of the viscoelastic dampers. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1217 / 1227
页数:11
相关论文