Profit rate performance optimization for a generalized irreversible combined refrigeration cycle

被引:6
|
作者
Ma, Kang [1 ]
Chen, Lingen [1 ]
Sun, Fengrui [1 ]
机构
[1] Naval Univ Engn, Postgrad Sch, Wuhan 430033, Hubei, Peoples R China
来源
SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES | 2009年 / 34卷 / 05期
关键词
Finite-time thermodynamics; generalized irreversible combined refrigeration cycle; exergoeconomic performance; generalized thermodynamic optimization; TIME EXERGOECONOMIC PERFORMANCE; ENTROPY GENERATION MINIMIZATION; HEAT-TRANSFER LAW; FINITE-TIME; THERMOECONOMIC OPTIMIZATION; ENERGY-SYSTEMS; ENGINES; PLANTS; ECONOMICS; PUMPS;
D O I
10.1007/s12046-009-0050-9
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Finite-time exergoeconomic performance of a Newtonian heat transfer law system generalized irreversible combined refrigeration cycle model with finite-rate heat transfer, heat leakage and internal irreversibility is presented in this paper. The operation of the generalized irreversible combined refrigeration cycle is viewed as a production process with exergy as its output. The performance optimization of the cycle is performed by taking profit as the objective. The optimal profit rate, optimal COP (coefficient of performance), as well as the relation between the optimal profit rate and COP of the cycle are derived. The focus of this paper is to obtain the compromise optimization between economics (profit rate) and the energy utilization factor (COP) for the cycle, by searching the optimum COP at maximum profit rate, which is termed as the finite time exergoeconomic performance bound. Moreover, the effects of various factors, including heat leakage, internal irreversibility and the price ratio, on the profit rate performance of the cycle are analysed by detailed numerical examples.
引用
收藏
页码:851 / 864
页数:14
相关论文
共 50 条
  • [31] Five performance indicators for a universal generalized irreversible steady flow cycle including seven specific refrigeration cycles
    Chen, Lingen
    Lorenzini, Giulio
    EUROPEAN PHYSICAL JOURNAL PLUS, 2022, 137 (04):
  • [32] Five performance indicators for a universal generalized irreversible steady flow cycle including seven specific refrigeration cycles
    Lingen Chen
    Giulio Lorenzini
    The European Physical Journal Plus, 137
  • [33] Ecological optimization of a multi-stage irreversible combined refrigeration system
    Chen, JC
    Chen, XL
    Wu, CH
    ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (17) : 2379 - 2393
  • [34] Optimization of a novel combined power/refrigeration thermodynamic cycle
    Lu, SG
    Goswami, DY
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (02): : 212 - 217
  • [35] Parametric analysis and optimization for a combined power and refrigeration cycle
    Wang, Jiangfeng
    Dai, Yiping
    Gao, Lin
    APPLIED ENERGY, 2008, 85 (11) : 1071 - 1085
  • [36] Optimal thermoeconomic performance of an irreversible regenerative ferromagnetic Ericsson refrigeration cycle
    Xu, Zhichao
    Guo, Juncheng
    Lin, Guoxing
    Chen, Jincan
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2016, 409 : 71 - 79
  • [37] Optimal analysis on the performance of an irreversible harmonic quantum Brayton refrigeration cycle
    Lin, BH
    Chen, JC
    PHYSICAL REVIEW E, 2003, 68 (05):
  • [38] Maximum-profit performance for generalized irreversible Carnot-engines
    Chen, LG
    Sun, FG
    Wu, CI
    APPLIED ENERGY, 2004, 79 (01) : 15 - 25
  • [39] OPTIMAL PERFORMANCE OF AN ENDOREVERSIBLE-COMBINED REFRIGERATION CYCLE
    CHEN, JC
    YAN, ZJ
    JOURNAL OF APPLIED PHYSICS, 1988, 63 (10) : 4795 - 4798
  • [40] The Performance Optimization of a Thermoacoustic Refrigeration Micro-cycle
    Kan Xuxian
    Wu Feng
    Shu Anqing
    Yu Shicheng
    Wu Kun
    Zou Wenjing
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 376 - +