WIDEBAND AIR-COUPLED PZT PIEZOELECTRIC MICROMACHINED ULTRASONIC TRANSDUCER THROUGH DC BIAS TUNING

被引:0
|
作者
Kusano, Yuri [1 ]
Wang, Qi [1 ]
Rudy, Ryan Q. [2 ]
Polcawich, Ronald G. [2 ]
Horsley, David A. [1 ]
机构
[1] Univ Calif Davis, Davis, CA 95616 USA
[2] US Army Res Lab, Adelphi, MD USA
关键词
OPTIMIZATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wide bandwidth for an air-coupled piezoelectric micromachined transducer (PMUT) is important to achieve short pulse transmission and reception in pulse-echo imaging with high axial resolution. Here, we report experimental results on an air-coupled PMUT with high displacement sensitivity up to 5500 nm/V, high 3 dB bandwidth of 20.3 kHz, and correspondingly short transmission time of 0.05 ms, achieved through dc bias tuning. The dc bias controls the polarization and intrinsic stress of the piezoelectric layer, tuning frequencies of two closely spaced resonance modes of the ribbon-shaped PMUT. The modes nearly overlapped when applying small dc bias around +/- 5 V, enabling wideband and short pulse transmission.
引用
收藏
页码:1204 / 1207
页数:4
相关论文
共 50 条
  • [1] Effects of DC Bias Tuning on Air-Coupled PZT Piezoelectric Micromachined Ultrasonic Transducers
    Kusano, Yuri
    Wang, Qi
    Luo, Guo-Lun
    Lu, Yipeng
    Rudy, Ryan Q.
    Polcawich, Ronald G.
    Horsley, David A.
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2018, 27 (02) : 296 - 304
  • [2] Design of air-coupled capacitive micromachined ultrasonic transducer
    Zhang, Hui
    Li, Zhi
    Zheng, Guanru
    Zeng, Zhoumo
    Shengxue Xuebao/Acta Acustica, 2019, 44 (01): : 116 - 124
  • [3] The effect of a closed back cavity on air-coupled piezoelectric micromachined ultrasonic transducer performance
    Gong, Yi
    Liu, Miaojie
    Gong, Shaobo
    Li, Quanning
    Chen, Xuejiao
    Pang, Wei
    Zhang, Menglun
    NANOTECHNOLOGY AND PRECISION ENGINEERING, 2025, 8 (03):
  • [4] Field characterization of an air-coupled micromachined ultrasonic capacitance transducer
    Bashford, AG
    Schindel, DW
    Hutchins, DA
    Wright, WMD
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (01): : 315 - 322
  • [5] Development of an Air-Coupled Piezoelectric Micromachined Ultrasonic Transducer Using Sol-Gel PZT Thin Film for Fast-Prototyping
    Liu, Ya-Han
    Lin, Hsiao-Chi
    Li, Chih-Ying
    Kao, Chien-Lun
    Hsu, Han-Jen
    Wang, Yeong-Her
    Huang, Chih-Hsien
    IEEE OPEN JOURNAL OF ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL, 2024, 4 : 27 - 36
  • [6] Air-coupled capacitive micromachined ultrasonic transducer for temperature field reconstruction
    Zhang, Hui
    Ma, Yongshuai
    Li, Shaojie
    Liu, Si
    Wang, Junjie
    Wang, Zhuochen
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [7] Design of a hexagonal air-coupled capacitive micromachined ultrasonic transducer for air parametric array
    Xiaoli Zhang
    Hui Zhang
    Dachao Li
    NanotechnologyandPrecisionEngineering, 2021, 4 (01) : 30 - 39
  • [8] Design of a hexagonal air-coupled capacitive micromachined ultrasonic transducer for air parametric array
    Zhang, Xiaoli
    Zhang, Hui
    Li, Dachao
    NANOTECHNOLOGY AND PRECISION ENGINEERING, 2021, 4 (01)
  • [9] Air-coupled piezoelectric micromachined ultrasonic transducers for surface stain detection and imaging
    Sheng Sun
    Jianyuan Wang
    Yuan Ning
    Menglun Zhang
    NanotechnologyandPrecisionEngineering, 2022, 5 (01) : 39 - 46
  • [10] Air-coupled piezoelectric micromachined ultrasonic transducers for surface stain detection and imaging
    Sun, Sheng
    Wang, Jianyuan
    Ning, Yuan
    Zhang, Menglun
    NANOTECHNOLOGY AND PRECISION ENGINEERING, 2022, 5 (01)