Development of extractive electrospray ionization ion trap mass spectrometry for in vivo breath analysis

被引:52
|
作者
Ding, Jianhua [1 ,2 ]
Yang, Shuiping [1 ]
Liang, Dapeng [2 ]
Chen, Huanwen [1 ,2 ]
Wu, Zhuanzhang [2 ]
Zhang, Lili [1 ]
Ren, Yulin [1 ]
机构
[1] Jilin Univ, Coll Chem, Changchun 130021, Peoples R China
[2] E China Inst Technol, Dept Appl Chem, Fuzhou 344000, Peoples R China
关键词
EXHALED BREATH; SYSTEMS BIOLOGY; CAPILLARY-ELECTROPHORESIS; DISCRIMINATING SIGNALS; SAMPLE PREPARATION; DRUG DISCOVERY; CARBON-DIOXIDE; METABOLOMICS; CONDENSATE; METABONOMICS;
D O I
10.1039/b821497b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In metabolomics studies and clinical diagnosis, interest is increasing in the rapid analysis of exhaled breath. In vivo breath analysis offers a unique, unobtrusive, non-invasive method of investigating human metabolism. To analyze breath in vivo, we constructed a novel platform of extractive electrospray ionization (EESI) ion trap mass spectrometry (ITMS) using a home-made EESI source coupled to a linear trap quadrupole mass spectrometer. A reference compound (authentic n-octyl amine) was used to evaluate effects of systematically varying selected characteristics of the EESI source on signal intensity. Under the optimized working conditions, metabolic changes of human bodies were in vivo followed by performing rapid breath analysis using the multi-stage EESI-ITMS tandem mass spectrometry platform. For nicotine, a limit of determination was found to be 0.05 fg mL(-1) (S/N = 3, RSD = 5.0 %, n = 10) for nicotine in aerosol standard samples; the dynamic response range was from 0.0155 pg mL(-1) to 155 pg mL(-1). The concentration of nicotine in the exhaled breath of a regular smoker was in vivo determined to be 5.8 pg mL(-1), without any sample pre-treatment. Our results show that EESI-ITMS is a powerful analytical platform to provide high sensitivity, high specificity and high throughput for semi-quantitative analysis of complex samples in life science, particularly for in vivo metabolomics studies.
引用
收藏
页码:2040 / 2050
页数:11
相关论文
共 50 条
  • [31] Characterization of Liver Failure by the Analysis of Exhaled Breath by Extractive Electrospray Ionization Mass Spectrometry (EESI-MS): A Pilot Study
    Wu, Xiaoping
    Zhang, Jianguo
    Yan, Xingyan
    Zhu, Ying
    Li, Wei
    Li, Penghui
    Chen, Huanwen
    Zhang, Wei
    Cheng, Na
    Xiang, Tianxin
    ANALYTICAL LETTERS, 2021, 54 (06) : 1038 - 1054
  • [32] ELECTROSPRAY IONIZATION OF PORPHYRINS USING A QUADRUPOLE ION TRAP FOR MASS ANALYSIS
    VANBERKEL, GJ
    MCLUCKEY, SA
    GLISH, GL
    ANALYTICAL CHEMISTRY, 1991, 63 (11) : 1098 - 1109
  • [33] DETERMINATION OF PYRIMIDINE CYCLOBUTANE DIMERS BY ELECTROSPRAY IONIZATION ION TRAP MASS-SPECTROMETRY
    RAMSEY, RS
    VANBERKEL, GJ
    MCLUCKEY, SA
    GLISH, GL
    BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (07) : 347 - 352
  • [34] Electrospray Ionization Ion Mobility Mass Spectrometry
    Kohoutek, Katie M.
    Harrington, Peter de B.
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2023, 53 (03) : 483 - 497
  • [35] Direct Analysis of Navel Orange Using Internal Extractive Electrospray Ionization Mass Spectrometry
    Lu Haiyan
    Zhang Hua
    Zhou Peng
    Yang Meiling
    Zhong Tao
    Yao Guocan
    Chen Huanwen
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2015, 36 (10): : 1912 - 1918
  • [36] Direct and Rapid Analysis of Avocado Using Internal Extractive Electrospray Ionization Mass Spectrometry
    Ke Mufang
    Han Jing
    Zhu Tenggao
    Liu Wenjie
    Zhang Hua
    Kou Wei
    Liang Dapeng
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2017, 38 (05): : 738 - 742
  • [37] Direct Molecular Analysis of Garlic Using Internal Extractive Electrospray Ionization Mass Spectrometry
    Zhang Hua
    Zhu Liang
    Chen Huan-Wen
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (11) : 1634 - U46
  • [38] Extractive Electrospray Ionization Mass Spectrometry toward in Situ Analysis without Sample Pretreatment
    Li, Ming
    Hu, Bin
    Li, Jianqiang
    Chen, Rong
    Zhang, Xie
    Chen, Huanwen
    ANALYTICAL CHEMISTRY, 2009, 81 (18) : 7724 - 7731
  • [39] Ion suppression effect in desorption electrospray ionization and electrospray ionization mass spectrometry
    Wang, Zheng
    Zhu, Haijing
    Huang, Guangming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (23) : 1957 - 1962
  • [40] Relative ion intensities of maltooligosaccharide ethers in electrospray ionization ion trap mass spectrometry: A quantitative evaluation
    Gangula, Sheetal
    Nimtz, Manfred
    Mischnick, Petra
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2016, 402 : 57 - 65