Quantification of lung microstructure with hyperpolarized 3He diffusion MRI

被引:120
|
作者
Yablonskiy, Dmitriy A. [1 ,2 ]
Sukstanskii, Alexander L.
Woods, Jason C. [2 ]
Gierada, David S.
Quirk, James D.
Hogg, James C. [4 ]
Cooper, Joel D. [3 ]
Conradi, Mark S. [2 ]
机构
[1] Washington Univ, Med Ctr, Mallinckrodt Inst Radiol, Dept Radiol, St Louis, MO 63110 USA
[2] Washington Univ, Dept Phys, St Louis, MO 63110 USA
[3] Washington Univ, Dept Surg, St Louis, MO 63110 USA
[4] St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
关键词
chronic obstructive pulmonary disease; lung morphometry; alveolar number; emphysema; alveolar size; AIRSPACE CHORD LENGTH; MAGNETIC-RESONANCE MEASUREMENTS; SCANNING-ELECTRON-MICROSCOPY; SURFACE-AREA; PULMONARY-EMPHYSEMA; SPIN-EXCHANGE; MORPHOMETRY; VIVO; PRESSURE; ACINUS;
D O I
10.1152/japplphysiol.00386.2009
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Yablonskiy DA, Sukstanskii AL, Woods JC, Gierada DS, Quirk JD, Hogg JC, Cooper JD, Conradi MS. Quantification of lung microstructure with hyperpolarized He-3 diffusion MRI. J Appl Physiol 107: 1258-1265, 2009. First published August 6, 2009; doi:10.1152/japplphysiol.00386.2009.-The structure and integrity of pulmonary acinar airways and their changes in different diseases are of great importance and interest to a broad range of physiologists and clinicians. The introduction of hyperpolarized gases has opened a door to in vivo studies of lungs with MRI. In this study we demonstrate that MRI-based measurements of hyperpolarized 3He diffusivity in human lungs yield quantitative information on the value and spatial distribution of lung parenchyma surface-to-volume ratio, number of alveoli per unit lung volume, mean linear intercept, and acinar airway radii-parameters that have been used by lung physiologists for decades and are accepted as gold standards for quantifying emphysema. We validated our MRI-based method in six human lung specimens with different levels of emphysema against direct unbiased stereological measurements. We demonstrate for the first time MRI images of these lung microgeometric parameters in healthy lungs and lungs with different levels of emphysema (mild, moderate, and severe). Our data suggest that decreases in lung surface area per volume at the initial stages of emphysema are due to dramatic decreases in the depth of the alveolar sleeves covering the alveolar ducts and sacs, implying dramatic decreases in the lung's gas exchange capacity. Our novel methods are sufficiently sensitive to allow early detection and diagnosis of emphysema, providing an opportunity to improve patient treatment outcomes, and have the potential to provide safe and noninvasive in vivo biomarkers for monitoring drug efficacy in clinical trials.
引用
收藏
页码:1258 / 1265
页数:8
相关论文
共 50 条
  • [21] Assessment of the lung microstructure in patients with asthma using hyperpolarized 3He diffusion MRI at two time scales:: Comparison with healthy subjects and patients with COPD
    Wang, Chengbo
    Altes, Talissa A.
    Mugler, John P., III
    Miller, G. Wilson
    Ruppert, Kai
    Mata, Jaime F.
    Cates, Gordon D., Jr.
    Borish, Larry
    de lange, Eduard E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) : 80 - 88
  • [22] High-speed dynamic MRI of lung ventilation with hyperpolarized 3He and EPI
    Yablonskiy, DA
    Gierada, DS
    Saam, BT
    Conradi, MS
    RADIOLOGY, 1998, 209P : 449 - 450
  • [23] MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT)
    C.P. Bidinosti
    J. Choukeife
    G. Tastevin
    P.-J. Nacher
    A. Vignaud
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 16 : 255 - 258
  • [24] MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT)
    Bidinosti, CP
    Choukeife, J
    Tastevin, G
    Vignaud, A
    Nacher, PJ
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 16 (06) : 255 - 258
  • [25] Hyperpolarized 3He apparent diffusion coefficient MRI of the lung:: Reproducibility and volume dependency in healthy volunteers and patients with emphysema
    Diaz, Sandra
    Casselbrant, Ingrid
    Piitulainen, Eeva
    Pettersson, Goran
    Magnusson, Peter
    Peterson, Barry
    Wollmer, Per
    Leander, Peter
    Ekberg, Olle
    Akeson, Per
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 763 - 770
  • [26] Quantification Of Ventilation Heterogeneity From Hyperpolarized 3he Mri: Relationship To Airway Hyperresponsiveness In Asthmatics
    Lui, J. K.
    Parameswaran, H.
    Albert, M. S.
    Lutchen, K. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [27] MR microscopy of lung airways with hyperpolarized 3He
    Chen, XJ
    Chawla, MS
    Hedlund, LW
    Möller, HE
    MacFall, JR
    Johnson, GA
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (01) : 79 - 84
  • [28] Diffusion lung imaging of hyperpolarized 3He in patients with emphysema: Changes in the structure of alveoli
    Yablonskiy, DA
    Saam, BT
    Gierada, DS
    Lefrak, SS
    Cooper, JD
    Conradi, MS
    RADIOLOGY, 1999, 213P : 344 - 344
  • [29] Dynamic Ventilation 3He MRI for the Quantification of Disease in the Rat Lung
    Kyriazis, Angelos.
    Rodriguez, I.
    Nin, N.
    Izquierdo-Garcia, J. L.
    Lorente, J. A.
    Perez-Sanchez, J. M.
    Pesic, J.
    Olsson, L. E.
    Ruiz-Cabello, J.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (03) : 777 - 786
  • [30] MRI of hyperpolarized 3He gas in human paranasal sinuses
    Rizi, RR
    Dimitrov, IE
    Thompson, A
    Jones, G
    Gentile, TR
    Ishii, M
    Reddy, R
    Schnall, MD
    Leigh, JS
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) : 865 - 868