Biological quality control for cardiopulmonary exercise testing in multicenter clinical trials

被引:8
|
作者
Porszasz, Janos [1 ]
Blonshine, Susan [2 ]
Cao, Robert [1 ]
Paden, Heather A. [3 ]
Casaburi, Richard [1 ]
Rossiter, Harry B. [1 ,4 ]
机构
[1] Harbor UCLA Med Ctr, Los Angeles Biomed Res Inst, Rehabil Clin Trials Ctr, 1124W Carson St,Bldg CDCRC, Torrance, CA 90502 USA
[2] TechEd Consultants Inc, Mason, MI USA
[3] Boehringer Ingelheim Pharmaceut Inc, 90 E Ridge POB 368, Ridgefield, CT 06877 USA
[4] Univ Leeds, Fac Biol Sci, Leeds, W Yorkshire, England
来源
BMC PULMONARY MEDICINE | 2016年 / 16卷
关键词
Calibration; Treadmill test; Pulmonary gas exchange; Z-score; Precision and accuracy; OBSTRUCTIVE PULMONARY-DISEASE; PEDALING RATES; TOLERANCE; COPD; RECOMMENDATIONS; HYPERINFLATION; TIOTROPIUM; ASSURANCE; BENEFITS; OXYGEN;
D O I
10.1186/s12890-016-0174-8
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Precision and accuracy assurance in cardiopulmonary exercise testing (CPET) facilitates multicenter clinical trials by maximizing statistical power and minimizing participant risk. Current guidelines recommend quality control that is largely based on precision at individual testing centers (minimizing test-retest variability). The aim of this study was to establish a multicenter biological quality control (BioQC) method that considers both precision and accuracy in CPET. Methods: BioQC testing was 6-min treadmill walking at 20 W and 70 W (below the lactate threshold) with healthy non-smoking laboratory staff (15 centers; similar to 16 months). Measurements were made twice within the initial 4 weeks and quarterly thereafter. Quality control was based on: 1) within-center precision (coefficient of variation [CV] for oxygen uptake [(V) over dotO(2)], carbon dioxide output [(V) over dotCO(2)], and minute ventilation [(V) over dotE] within +/- 10 %); and 2) a criterion that (V) over dotO(2) at 20 W and 70 W, and Delta(V) over dotO(2)/Delta WR were each within +/- 10 % predicted. "Failed" BioQC tests (i.e., those outside the predetermined criterion) prompted troubleshooting and repeated measurements. An additional retrospective analysis, using a composite z-score combining both BioQC precision and accuracy of (V) over dotO(2) at 70 W and Delta(V) over dotO(2)/Delta WR, was compared with the other methods. Results: Of 129 tests (5 to 8 per center), 98 (76 %) were accepted by within-center precision alone. Within-center CV was <9 %, but between-center CV remained high (9.6 to 12.5 %). Only 43 (33 %) tests had all (V) over dotO(2) measurements within the +/- 10 % predicted criterion. However, a composite z-score of 0.67 identified 67 (52 %) non-normal outlying tests, exclusion of which coincided with the minimum CV for CPET variables. Conclusions: Study-wide BioQC using a composite z-score can increase study-wide precision and accuracy, and optimize the design and conduct of multicenter clinical trials involving CPET.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Exercise Physiology and Cardiopulmonary Exercise Testing
    Sietsema, Kathy E.
    Rossiter, Harry B.
    SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 44 (05) : 661 - 680
  • [42] CARDIOPULMONARY EXERCISE TESTING - METHODOLOGY AND CLINICAL-APPLICATION - FOREWORD
    不详
    ZEITSCHRIFT FUR KARDIOLOGIE, 1994, 83 : R5 - R5
  • [43] Clinical Usefulness of Cardiopulmonary Exercise Testing in a Patient with Laryngotracheal Disorders
    Foster, K. E.
    Wood, R. E.
    Hardie, W. D.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [44] Cardiopulmonary Exercise Testing Current Applications and Future Clinical Potential
    deJong, Adam
    ACSMS HEALTH & FITNESS JOURNAL, 2011, 15 (02) : 43 - 45
  • [45] Cardiopulmonary exercise testing - refining the clinical perspective by combining assessments
    Arena, Ross
    Canada, Justin M.
    Popovic, Dejana
    Trankle, Cory R.
    Del Buono, Marco Giuseppe
    Lucas, Alexander
    Abbate, Antonio
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2020, 18 (09) : 563 - 576
  • [46] Clinical Interpretation of Cardiopulmonary Exercise Testing: Current Pitfalls and Limitations
    Neder, J. Alberto
    Phillips, Devin B.
    Marillier, Mathieu
    Bernard, Anne-Catherine
    Berton, Danilo C.
    O'Donnell, Denis E.
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [47] Clinical safety and usefulness of cardiopulmonary exercise testing for pulmonary hypertension
    Hirashiki, A.
    Kondo, T.
    Adachi, S.
    Shimizu, S.
    Shimazu, S.
    Kono, Y.
    Yamada, S.
    Okumura, T.
    Takeshita, K.
    Murohara, T.
    EUROPEAN HEART JOURNAL, 2013, 34 : 635 - 635
  • [48] Exertional dyspnoea in COPD: the clinical utility of cardiopulmonary exercise testing
    O'Donnell, Denis E.
    Elbehairy, Amany F.
    Faisal, Azmy
    Webb, Katherine A.
    Neder, J. Alberto
    Mahler, Donald A.
    EUROPEAN RESPIRATORY REVIEW, 2016, 25 (141): : 333 - 347
  • [49] Clinical recommendations for cardiopulmonary exercise testing in children with respiratory diseases
    Takken, Tim
    Sonbahar Ulu, Hazal
    Hulzebos, Erik H. J.
    EXPERT REVIEW OF RESPIRATORY MEDICINE, 2020, 14 (07) : 691 - 701
  • [50] COMPLICATIONS OF CARDIOPULMONARY EXERCISE TESTING
    Bernskoetter, Nicole
    Addanki, Pruthwy
    Bhandari, Kaamya
    Datta, Debapriya
    CHEST, 2022, 162 (04) : 2275A - 2275A