Exercise capacity assessed with the one-minute sit-to-stand test (1-min STST) and echocardiographic findings in patients with heart failure with preserved ejection fraction (HFpEF)

被引:9
|
作者
Kronberger, Christina [1 ]
Mousavi, Roya Anahita [1 ]
Ozturk, Begum [1 ]
Dachs, Theresa-Marie [1 ]
Rettl, Rene [1 ]
Camuz-Ligios, Luciana [1 ]
Litschauer, Brigitte [2 ]
Badr-Eslam, Roza [1 ]
机构
[1] Med Univ Vienna, Div Cardiol, Dept Internal Med 2, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Clin Pharmacol, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
来源
HEART & LUNG | 2022年 / 55卷
关键词
Sit-to-stand test; Heart failure with preserved ejection fraction; PHYSICAL-ACTIVITY; RELIABILITY; PERFORMANCE; VALIDITY; FITNESS; INDEX;
D O I
10.1016/j.hrtlng.2022.05.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Heart failure with preserved ejection fraction (HFpEF) is a major cause of morbidity and mortality. Precise risk stratification remains challenging. The one-minute sit-to-stand-test (1-min STST), a quick, objective test of functional capacity may be helpful for stratification of clinical profile in HFpEF patients. Objective: The aim of this initial investigation was to prospectively examine whether the 1-min STST can be used for the evaluation of exercise capacity in HFpEF patients and whether it is in line with echocardiographic as well as quality of life (QoL) findings. Methods: 39 HFpEF patients were prospectively studied. Functional performance was examined with the 1-min STST and QoL with the CAMPHOR questionnaire. Clinical parameters including echocardiographic measurements [estimated pulmonary artery systolic pressure (ePASP), tricuspid regurgitation velocity (TRV)] were obtained. Patients were divided into two groups based on their number of 1-min STST repetitions (Group I: <= 50% of predicted 1-min STST repetitions using the norm-reference values developed by Strass-mann et al. for healthy people, N=24; Group II: >50% of predicted 1-min STST repetitions, N=15). Results: Patients in group I with limited 1-min STST performance showed worse echocardiographic parameters [higher ePASP (p=0.038), higher TRV (p=0.018) and more reduced tricuspid annular plane systolic excursion (TAPSE) (p=0.001)], worse six-minute walk test (6MWT) (p<0.001) and worse QoL (p<0.001) compared to patients in group II. Conclusion: Our study shows potential usefulness of the 1-min STST as an evaluative tool for exercise capacity in HFpEF patients, because patients with worse 1-min STST performance have worse clinical parameters and QoL. (c) 2022 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)
引用
收藏
页码:134 / 139
页数:6
相关论文
共 34 条
  • [31] Echocardiographic and neurohormonal predictors of impaired sub-maximal exercise capacity assessed by six-minute walk test in patients with chronic systolic heart failure: An ADEPT ancillary substudy
    Whitman, C
    Jasper, S
    Tang, WHW
    Troughton, RW
    Martin, MG
    Klein, AL
    JOURNAL OF CARDIAC FAILURE, 2005, 11 (06) : S124 - S124
  • [32] Effects of Interleukin-1 Blockade With Anakinra on Aerobic Exercise Capacity in Patients With Heart Failure and Preserved Ejection Fraction (from the D-HART Pilot Study)
    Van Tassell, Benjamin Wallace
    Arena, Ross
    Biondi-Zoccai, Giuseppe
    Canada, Justin McNair
    Oddi, Claudia
    Abouzaki, Nayef Antar
    Jahangiri, Arehzo
    Falcao, Raquel Appa
    Kontos, Michael Christopher
    Shah, Keyur Bharat
    Voelkel, Norbert Felix
    Dinarello, Charles Anthony
    Abbate, Antonio
    AMERICAN JOURNAL OF CARDIOLOGY, 2014, 113 (02): : 321 - 327
  • [33] Impact of Combined Exercise and High-Intensity Interval Training on 6-Minute Walk Test Dynamics in Heart Failure Patients with Preserved Ejection Fraction: Results from the ExIC-FEp Trial
    Cavero-Redondo, Ivan
    Martinez-Rodrigo, Arturo
    Otero-Luis, Iris
    Moreno-Herraiz, Nerea
    Fenoll-Morante, Marta
    Martinez-Garcia, Irene
    Guzman-Pavon, Maria Jose
    Saz-Lara, Alicia
    APPLIED SCIENCES-BASEL, 2024, 14 (21):
  • [34] Accuracy of the 6-Minute Walk Test for Assessing Functional Capacity in Patients With Heart Failure With Preserved Ejection Fraction and Other Chronic Cardiac Pathologies: Results of the ExIC-FEp Trial and a Meta-Analysis
    Cavero-Redondo, Ivan
    Saz-Lara, Alicia
    Bizzozero-Peroni, Bruno
    Nunez-Martinez, Laura
    Diaz-Goni, Valentina
    Calero-Paniagua, Ismael
    Matinez-Garcia, Irene
    Pascual-Morena, Carlos
    SPORTS MEDICINE-OPEN, 2024, 10 (01)