Microfluidic deformability analysis of the red cell storage lesion

被引:43
|
作者
Matthews, Kerryn [1 ]
Myrand-Lapierre, Marie-Eve [1 ]
Ang, Richard R. [1 ]
Duffy, Simon P. [1 ]
Scott, Mark D. [2 ,3 ,4 ]
Ma, Hongshen [1 ,2 ,5 ,6 ]
机构
[1] Univ British Columbia, Dept Mech Engn, Vancouver, BC V6T 1Z4, Canada
[2] Univ British Columbia, Ctr Blood Res, Vancouver, BC V6T 1Z4, Canada
[3] Univ British Columbia, Dept Pathol & Lab Med, Vancouver, BC V6T 1Z4, Canada
[4] Univ British Columbia, Canadian Blood Serv, Vancouver, BC V6T 1Z4, Canada
[5] Univ British Columbia, Dept Urol Sci, Vancouver, BC V6T 1Z4, Canada
[6] Vancouver Gen Hosp, Vancouver Prostate Ctr, Vancouver, BC, Canada
基金
加拿大健康研究院;
关键词
RBC Deformability; Storage; Blood bags; BLOOD-CELLS; TRANSFUSED BLOOD; AGE; SUSCEPTIBILITY; EKTACYTOMETRY; ERYTHROCYTES; ASSOCIATION; CHOLESTEROL; SIMVASTATIN; MORTALITY;
D O I
10.1016/j.jbiomech.2015.10.002
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A key challenge in transfusion medicine research and clinical hematology is to develop a simple and non-destructive method to measure the quality of each blood unit prior to use. RBC deformability has long been proposed as an indicator of blood quality. We measured RBC deformability using the pressure required for single cells to transit through a micrometer scale constriction to examine longitudinal changes in RBC deformability, as well as the variability in blood quality and storage capacity across donors. We used a microfluidic device to monitor deformability changes in RBCs stored in plastic tubes and in blood bags over 14 and 56 days respectively. We found consistent storage based degradation of RBC deformability with statistically significant variability in both the initial RBC deformability and storage capacity among donors. Furthermore, all samples exhibited a transient recovery phenomenon. Deformability profiling of stored RBCs using transiting pressure showed significant donor variability in initial quality and storage capacity. This measurement approach shows promise as a rapid method to individually assess the quality of stored RBC units. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4065 / 4072
页数:8
相关论文
共 50 条
  • [31] The red blood cell storage lesion: the end of the beginning
    Glynn, Simone A.
    Klein, Harvey G.
    Ness, Paul M.
    TRANSFUSION, 2016, 56 (06) : 1462 - 1468
  • [32] The red cell storage lesion and its implication for transfusion
    ChinYee, I
    Arya, N
    dAlmeida, MS
    TRANSFUSION SCIENCE, 1997, 18 (03): : 447 - 458
  • [33] Deformability based cell margination - A simple microfluidic design for malarial infected red blood cell filtration
    Hou, Han Wei
    Bhagat, Ali Asgar. S.
    Han, Jongyoon
    Lim, Chwee Teck
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 1671 - 1674
  • [34] RED-CELL DEFORMABILITY
    DORMANDY, JA
    MICROVASCULAR RESEARCH, 1979, 17 (02) : 209 - 209
  • [35] RED-CELL DEFORMABILITY
    RAMPLING, MW
    SIRS, JA
    LANCET, 1976, 1 (7965): : 905 - 905
  • [36] RED-CELL DEFORMABILITY
    REID, H
    DORMANDY, JA
    BARNES, AJ
    LOCK, P
    DORMANDY, TL
    LANCET, 1976, 1 (7968): : 1086 - 1086
  • [37] RED-CELL DEFORMABILITY
    不详
    LANCET, 1978, 2 (8104): : 1348 - 1349
  • [38] Microfluidic cell-phoresis enabling high-throughput analysis of red blood cell deformability and biophysical screening of antimalarial drugs
    Santoso, Aline T.
    Deng, Xiaoyan
    Lee, Jeong-Hyun
    Matthews, Kerryn
    Duffy, Simon P.
    Islamzada, Emel
    McFaul, Sarah M.
    Myrand-Lapierre, Marie-Eve
    Ma, Hongshen
    LAB ON A CHIP, 2015, 15 (23) : 4451 - 4460
  • [39] RED-CELL DEFORMABILITY
    DORMANDY, JA
    EUROPEAN NEUROLOGY, 1983, 22 : 23 - 29
  • [40] Degradation of Red Blood Cell Deformability during Cold Storage in Blood Bags
    Islamzada, Emel
    Matthews, Kerryn
    Lamoureux, Erik
    Scott, Mark D.
    Ma, Hongshen
    BLOOD, 2021, 138