Quantification of the electron donating capacity and UV absorbance of dissolved organic matter during ozonation of secondary wastewater effluent by an assay and an automated analyzer

被引:52
|
作者
Walpen, Nicolas [1 ]
Houska, Joanna [1 ,3 ]
Salhi, Elisabeth [1 ]
Sander, Michael [2 ]
von Gunten, Urs [1 ,2 ,3 ]
机构
[1] Swiss Fed Inst Aquat Sci & Technol Eawag, CH-8600 Dubendorf, Switzerland
[2] Swiss Fed Inst Technol, Inst Biogeochem & Pollutant Dynam, CH-8092 Zurich, Switzerland
[3] Ecole Polytech Fed Lausanne EPFL, Sch Architecture Civil & Environm Engn ENAC, CH-1015 Lausanne, Switzerland
关键词
Secondary-treated wastewater; Ozonation; Micropollutant abatement; Electron donating capacity; UV absorbance; MICROPOLLUTANT ELIMINATION; TRANSFORMATION PRODUCTS; ULTRAVIOLET ABSORBENCY; OZONE DECOMPOSITION; ADVANCED OXIDATION; CORRELATION MODELS; BROMATE FORMATION; CHLORINE; PHARMACEUTICALS; INDICATOR;
D O I
10.1016/j.watres.2020.116235
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ozonation of secondary wastewater treatment plant effluent for the abatement of organic micropollutants requires an accurate process control, which can be based on monitoring ozone-induced changes in dissolved organic matter (DOM). This study presents a novel automated analytical system for monitoring changes in the electron donating capacity (EDC) and UV absorbance of DOM during ozonation. In a first step, a quantitative photometric EDC assay was developed based on electron-transfer reactions from phenolic moieties in DOM to an added chemical oxidant, the radical cation of 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonate) (ABTS(center dot+)). The assay is highly sensitive (limit of quantification similar to 0.5 mg(DOC.)L(-1)) and EDC values of model DOM isolates determined by this assay were in good agreement with values determined previously by mediated electrochemical oxidation (slope = 1.01 +/- 0.07, R-2 = 0.98). In a second step, the photometric EDC measurement method was transferred onto an automated fluidic system coupled to a photometer (EDC analyzer). The EDC analyzer was then used to monitor changes in EDC and UV absorbance of secondary wastewater effluent treated with ozone. While both parameters exhibited a dose-dependent decrease, a more pronounced decrease in EDC as compared to UV absorbance was observed at specific ozone doses up to 0.4 mg(O3)center dot g(DOC)(-1). The concentration of 17 alpha-ethinylestradiol, a phenolic micropollutant with a high ozone reactivity, decreased proportionally to the EDC decrease. In contrast, abatement of less ozone-reactive micropollutants and bromate formation started only after a pronounced initial decrease in EDC. The on-line EDC analyzer presented herein will enable a comprehensive assessment of the combination of EDC and UV absorbance as control parameters for full-scale ozonation. (C) 2020 The Authors. Published by Elsevier Ltd.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Unveiling the transformation of dissolved organic matter during ozonation of municipal secondary effluent based on FT-ICR-MS and spectral analysis
    Zhang, Bingliang
    Shan, Chao
    Wang, Shu
    Fang, Zhuoyao
    Pan, Bingcai
    WATER RESEARCH, 2021, 188
  • [22] Nano Fe3O4 improved the electron donating capacity of dissolved organic matter during sludge composting
    Chen, Liu
    Zhang, Zeyu
    Yang, Rui
    Wang, Xiaojie
    Yu, Jieyu
    Jiang, Hong
    Zhang, Wenjie
    Xi, Beidou
    Sun, Xiaojie
    Li, Ningjie
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2024, 369
  • [24] Fate of secondary effluent dissolved organic matter during soil-aquifer treatment
    Xue Shuang
    Zhao QingLiang
    Wei LiangLiang
    Wang Lina
    Liu ZhiGang
    CHINESE SCIENCE BULLETIN, 2007, 52 (18): : 2496 - 2505
  • [25] Understanding the influence of pre-ozonation on the formation of disinfection byproducts and cytotoxicity during post-chlorination of natural organic matter: UV absorbance and electron-donating-moiety of molecular weight fractions
    Wang, Wen-Long
    Lee, Min-Yong
    Du, Ye
    Zhou, Tian-Hui
    Yang, Zheng-Wei
    Wu, Qian-Yuan
    Hu, Hong-Ying
    ENVIRONMENT INTERNATIONAL, 2021, 157
  • [26] Investigation on degradation behavior of dissolved effluent organic matter, organic micro-pollutants and bio-toxicity reduction from secondary effluent treated by ozonation
    Li, Mo
    Chen, Zhiqiang
    Wang, Zhenzhe
    Wen, Qinxue
    CHEMOSPHERE, 2019, 217 : 223 - 231
  • [27] Combination of MIEXA® resin and ozonation for reduction of dissolved organic matter during aquifer recharge using municipal effluent
    Zhang, Xue
    Zhao, Xuan
    Gao, Yutuan
    Zhang, Meng
    ENVIRONMENTAL EARTH SCIENCES, 2015, 73 (12) : 7781 - 7787
  • [28] Combination of MIEX® resin and ozonation for reduction of dissolved organic matter during aquifer recharge using municipal effluent
    Xue Zhang
    Xuan Zhao
    Yutuan Gao
    Meng Zhang
    Environmental Earth Sciences, 2015, 73 : 7781 - 7787
  • [29] Removal and transformation of dissolved organic matter in secondary effluent during granular activated carbon treatment
    Wei, Liang-liang
    Zhao, Qing-liang
    Xue, Shuang
    Jia, Ting
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2008, 9 (07): : 994 - 1003
  • [30] Effect of bromide ion on isolated fractions of dissolved organic matter in secondary effluent during chlorination
    Xue, Shuang
    Zhao, Qing-Liang
    Wei, Liang-Liang
    Jia, Ting
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 157 (01) : 25 - 33