Lens surface roughening for tears invariant contact lens performance

被引:0
|
作者
Zalevsky, Zeev [1 ]
Azogui, Jonathan [1 ]
Limon, Ofer [2 ]
Rudnitsky, Arkady [1 ]
机构
[1] Bar Ilan Univ, Fac Engn, IL-52900 Ramat Gan, Israel
[2] Xceed Imaging Ltd, Petah Tiqwa, Israel
关键词
Ophthalmic devices; Contact lenses; Rough surfaces; BINARY; PRESBYOPIA; DEPTH;
D O I
10.1016/j.optcom.2013.10.089
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In many extended depth of focus diffractive or interferometry based ophthalmic contact lenses the time varied tears layers affect the ophthalmic functionality of the lens. In this paper we present a new approach involving nano pillars realized inside the grooves of a contact lens aiming to implement any type of extended depth of focus or diffractive optical element for ophthalmic applications in order to solve the micro fluidics layer uncertainty within the micro sag features. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:168 / 175
页数:8
相关论文
共 50 条
  • [31] Ocular surface health with contact lens wear
    Shovlin, Joseph P.
    CONTACT LENS & ANTERIOR EYE, 2013, 36 : S14 - S21
  • [32] Contact lens care and ocular surface homeostasis
    Efron, Nathan
    CONTACT LENS & ANTERIOR EYE, 2013, 36 : S9 - S13
  • [33] Ocular Surface Response in Contact Lens Wearers
    Muselier, A., Jr.
    Souchier, M.
    Mathieu, B.
    Gregoire, S.
    Nicot, F.
    Baudouin, F.
    Bretillon, L.
    Bron, A. M.
    Creuzot-Garcher, C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [34] ARTIFICIAL TEARS OR LENS CLEANER
    TO, K
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (05) : 610 - 610
  • [35] Contact lens
    Sattler, CH
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1941, 67 : 574 - 576
  • [36] A contact lens
    Fick, AE
    ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (01) : 120 - 121
  • [37] CONTACT LENS
    STONE, W
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1963, 184 (08): : 668 - &
  • [38] Contact lens
    Hartinger, H
    NATURWISSENSCHAFTEN, 1931, 19 : 669 - +
  • [39] Secretory IgA in basal tears of contact lens wearers with and without an adverse response, and non lens wearing controls.
    Pearce, DJ
    Demirci, G
    Willcox, MDP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S672 - S672
  • [40] Surface Roughness and Refractive Index Changes in Contact Lens Induced by Lens Care Systems
    Lira, Madalena
    Franco, Sandra
    Benito Vazquez-Dorrio, Jose
    Real Oliveira, M. Elisabete C. D.
    Costa, Manuel F. M.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (03): : 140 - 147