Evaluation of the effect of nanocoated window glazing films on the thermal behavior of buildings

被引:1
|
作者
Almogbel, Ahmed M. [1 ]
Hussain, Shafqat [2 ]
Kalendar, Abdulrahim [3 ]
机构
[1] King Abdulaziz City Sci & Technol, Water & Energy Res Inst, Dept Water & Energy Res, Riyadh, Saudi Arabia
[2] Univ Lahore, Dept Mech Engn, 1 Km Raiwind Rd, Lahore 54000, Punjab, Pakistan
[3] Coll Technol Studies PAAET, Dept Mech Power & Refrigerat Technol, Shuwaikh, Kuwait
关键词
antimony tin oxide films; clear window glass; glass coating; glazed room; numerical simulations; SOLAR HEAT GAIN; PERFORMANCE; SIMULATION; GLASS;
D O I
10.1002/htj.21999
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, different coating samples of antimony tin oxide (ATO) films on clear glass were prepared and their optical and thermal properties were evaluated. Performance parameters such as glass U-factor, solar heat gain coefficient, temperature distribution, and net heat transfer gain using the glazed walls inside the test room were determined through numerical simulations. The results obtained indicate that the nanocoating thickness and doping level concentration of ATO films have a pronounced effect on the thermal insulation of the window glass. When compared with normal window clear glass, the transmittance of solar radiation for ATO thin-film coating of thickness 1140 nm reduced from 0.881 to 0.114 in the visible (VIS) region and 0.817 to 0.012 in the infrared (IR) region, whereas radiation in the ultraviolet (UV) region was almost completely blocked. Similarly, for the ATO films with doping level 15%, the transmittance value reduced from 0.742 to 0.432 in the VIS region and from 0.718 to 0.114 in the IR region, and radiation in the UV region was almost totally blocked. Finally from the analysis of results, it was observed that the ATO thin films show exceptional optical and thermal properties and exhibit improved solar blocking behavior when compared with commercially available glazing (eg, from Saudi Arabian glass companies).
引用
收藏
页码:2667 / 2685
页数:19
相关论文
共 50 条
  • [11] Thermal performance of a room with a double glazing window using glazing available in Mexican market
    Aguilar, J. O.
    Xaman, J.
    Olazo-Gomez, Y.
    Hernandez-Lopez, I.
    Becerra, G.
    Jaramillo, O. A.
    APPLIED THERMAL ENGINEERING, 2017, 119 : 505 - 515
  • [12] Acoustic behavior of high acoustic performance window glazing
    Mateus, Diogo
    Pereira, Andreia
    Tadeu, Antonio
    NOISE CONTROL ENGINEERING JOURNAL, 2013, 61 (03) : 320 - 329
  • [13] PCBs in Older Buildings: Measuring PCB Levels in Caulk and Window Glazing Materials in Older Buildings
    Osemwengie, Lantis, I
    Morgan, Jade
    ENVIRONMENTS, 2019, 6 (02):
  • [14] Computational fluid dynamics for thermal evaluation of a room with a double glazing window with a solar control film
    Xaman, J.
    Olazo-Gomez, Y.
    Chavez, Y.
    Hinojosa, J. F.
    Hernandez-Perez, I.
    Hernandez-Lopez, I.
    Zavala-Guillen, I.
    RENEWABLE ENERGY, 2016, 94 : 237 - 250
  • [15] Thermal evaluation of a Room coupled with a Double Glazing Window with/without a solar control film for Mexico
    Xaman, J.
    Olazo-Gomez, Y.
    Zavala-Guillen, I.
    Hernandez-Perez, I.
    Aguilar, J. O.
    Hinojosa, J. F.
    APPLIED THERMAL ENGINEERING, 2017, 110 : 805 - 820
  • [16] Evaluation of the fatigue resistance of glazing sealants during cure - Window glazing sealant selection
    Block, SR
    DURABILITY OF BUILDING SEALANTS, 1999, 36 : 23 - 29
  • [17] Thermal performance evaluation of phase changing materials in double glazing units for office buildings in Egypt
    Abdel-Rahman, Omar
    El Rouby
    Afify, Mohamed Moemen
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [18] Energy Cost Saving Prospects in Buildings Using Various Window Glazing in Dhaka
    Gorantla, Kiran Kumar
    Saboor, Shaik
    Sobuz, Habibur Rahman
    Vankadaru, Sai Siva Subramanyam
    Arumugam, Chelliah
    INTERNATIONAL ENERGY JOURNAL, 2020, 20 : 485 - 496
  • [19] Energy cost saving prospects in buildings using various window glazing in Dhaka
    Department of Mechanical Engineering, Sasi Institute of Technology and Engineering, Tadepalligudem, India
    不详
    不详
    Int. Energy J., (485-496): : 485 - 496