Evaluation of Physicochemical Parameters of Piroxicam 20 mg Tablets Commercially Available in District Larkana, Sindh

被引:0
|
作者
Ahmed, Waqar [1 ]
Ghoto, Muhammad Ali [2 ]
Mughal, Ubed-ur-Rehman [1 ]
Dayo, Abdullah [1 ]
Arain, Mudassar Lqbal [2 ]
Ahmer, Arslan [3 ]
Irfan, Rao [3 ]
Shaikh, Bilawal [3 ]
Qazi, Maryam [4 ]
Khan, Komal Zaman [5 ]
机构
[1] Univ Sindh, Dept Pharmaceut, Fac Pharm, Jamshoro, Sindh, Pakistan
[2] Univ Sindh, Dept Pharm Practice, Fac Pharm, Jamshoro, Sindh, Pakistan
[3] Peoples Univ Med & Hlth Sci Women PUMHSW, Inst Pharmaceut Sci, Nawabshah, Sindh, Pakistan
[4] Shaheed Mohtarma Benazir Bhutto Med Univ SMBBMU L, Inst Pharm, Sindh, Pakistan
[5] Liaquat Univ Med & Hlth Sci LUMHS, Coll Pharm, Jamshoro, Sindh, Pakistan
关键词
Piroxicam; NSAIDS; diameter; analgesic; friability; DESIGN;
D O I
10.9734/JPRI/2020/v32i3230936
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The objective of this study is to evaluate the physicochemical parameters of Piroxicam 20 mg Tablet brands. A comparative qualitative research study was conducted for a period of six months. A total of five different brands of active Piroxicam tablets were selected. All samples were purchased from various local markets of Larkana Sindh. These collected samples were coded as PIX01, PIX02, PIX03, PIX04 and PIX05 for minimalism. Specific physicochemical quality control lab tests included Aesthetic test, Diameter and Thickness test, Weight variation, Mechanical strength and Friability test were performed on each sample according to standards and results were compared. Packing of all samples was observed according to GMP guidelines. Data was analyzed by using statistical software SPSS 24.00. Most of the brands were within official limits of United State Pharmacopeia (USP) except brand PIX05 showing variation in hardness test, whereas two brands PIX03 and PIX05 fail in friability test as well as powder material seen inside of blisters in aesthetic test. Dissolution test for each brand of Piroxicam was performed in which PIX02, 04 and 05 failed. It was concluded that from this study after in vitro physical evaluation of various brands of Piroxicam tablets, most of the brands are being manufactured under compliance of GMP guidelines as well as specifications described under USP. Traces of powder material inside of blister in aesthetic test and unsatisfactory result in friability and hardness test in same brand indicating the deviation of GMP guidelines and USP specification which may cause the out of specification result in chemical test.
引用
收藏
页码:82 / 87
页数:6
相关论文
共 44 条
  • [41] Evaluation of physicochemical parameters of water samples around proposed Nuclear Power Plant (NPP) in Kovvada, Srikakulam District, Andhra Pradesh, India
    Mamidi, Yugandhar
    Reddy, Gopireddy V. Subba
    Ramarao, D.
    Sahoo, S. K.
    Lokesh, Budigi
    Gadamsetty, Ganesh
    David, Ezhumalai
    MATERIALS TODAY-PROCEEDINGS, 2022, 62 : 5690 - 5699
  • [42] Evaluation of physicochemical and microbiological parameters, and their correlation in Himalayan Spring Water Systems: A case study of District Kulgam of Kashmir Valley, India, Western Himalaya
    Nisa, Fahim Un
    Umar, Rashid
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2023, 195 (04)
  • [43] Evaluation of physicochemical and microbiological parameters, and their correlation in Himalayan Spring Water Systems: A case study of District Kulgam of Kashmir Valley, India, Western Himalaya
    Fahim Un Nisa
    Rashid Umar
    Environmental Monitoring and Assessment, 2023, 195
  • [44] A 4-week, double-blind, parallel-group study to compare the gastrointestinal effects of meloxicam 7.5 mg, meloxicam 15 mg, piroxicam 20 mg and placebo by means of faecal blood loss, endoscopy and symptom evaluation in healthy volunteers
    Patoia, L
    Santucci, L
    Furno, P
    Dionisi, MS
    DellOrso, S
    Romagnoli, M
    Sattarinia, A
    Marini, MG
    BRITISH JOURNAL OF RHEUMATOLOGY, 1996, 35 : 61 - 67