Improved photon dose calculation in the lung with the analytical anisotropic algorithm (AAA)

被引:0
|
作者
Huyskens, D.
Van Esch, A.
Pyykkonen, J.
Tenhunen, M.
Hannu Helminen, H.
Tillikainen, L.
Siljamaki, S.
Alakuijala, J.
机构
[1] 7Sigma, QA Team Radiotherapy Phys, Tildonk, Belgium
[2] Univ Hosp, Dept Oncol, Helsinki, Finland
[3] Varian Med Sys, Helsinki, Finland
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
1266
引用
收藏
页码:S513 / S513
页数:1
相关论文
共 50 条
  • [11] Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water
    Fogliata, A
    Nicolini, G
    Vanetti, E
    Clivio, A
    Cozzi, L
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06): : 1421 - 1438
  • [12] A plan intercomparison study for the Anisotropic Analytical Algorithm, the collapsed cone and the pencil beam algorithm for photon dose calculation
    Fogliata, A.
    Nicolini, G.
    Vanetti, E.
    Clivio, A.
    Cozzi, L.
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 : S79 - S79
  • [13] AAA vs Monte Carlo Dose Calculation Algorithm for Lung SABR
    Badragan, I.
    Huang, V.
    Shellenberg, D.
    Krauze, A.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S982 - S983
  • [14] The accuracy of dose calculation in wedge fields of the Analytical Anisotropic Algorithm for 6 and 10 MV photon beams
    Rutchantuek, S.
    Stansook, N.
    Changkaew, P.
    Sakulsingharoj, S.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S179 - S180
  • [15] Preliminary results from anisotropic analytical algorithm for photon dose calculation on Siemens and Elekta linear accelerators
    Cozzi, L.
    Glashoerster, M.
    Nicolini, G.
    Seelentag, W.
    Fogliata, A.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S30 - S30
  • [16] VERIFICATION OF PHOTON DOSE CALCULATION ACCURACY BY THE PENCIL BEAM AND ANALYTICAL ANISOTROPIC ALGORITHM USING MOSFET DETECTORS
    Swinnen, A.
    Nulens, A.
    Verstraete, J.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S414 - S414
  • [17] Comparison of Acuros (AXB) and Anisotropic Analytical Algorithm (AAA) for dose calculation in treatment of oesophageal cancer: effects on modelling tumour control probability
    Sriram Padmanaban
    Samantha Warren
    Anthony Walsh
    Mike Partridge
    Maria A Hawkins
    Radiation Oncology, 9
  • [18] Comparison of Acuros (AXB) and Anisotropic Analytical Algorithm (AAA) for dose calculation in treatment of oesophageal cancer: effects on modelling tumour control probability
    Padmanaban, Sriram
    Warren, Samantha
    Walsh, Anthony
    Partridge, Mike
    Hawkins, Maria A.
    RADIATION ONCOLOGY, 2014, 9
  • [19] Evaluating small field dosimetry with the Acuros XB (AXB) and analytical anisotropic algorithm (AAA) dose calculation algorithms in the eclipse treatment planning system
    Behinaein, Sepideh
    Osei, Ernest
    Darko, Johnson
    Charland, Paule
    Bassi, Dylan
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (04) : 353 - 364
  • [20] Evaluation of the Sensitivity of the Anisotropic Analytical Algorithm (AAA) to the Commissioning Dataset
    Yaldo, D.
    Tailor, R.
    Scarboro, S.
    Sahoo, N.
    Kry, S.
    Kisling, K.
    Followill, D.
    Howell, R.
    MEDICAL PHYSICS, 2010, 37 (06)