Preventing cascading failure of electric power protection systems in nuclear power plant

被引:3
|
作者
Moustafa, Abdelrahman Mohamed Mohamed Moustafa [1 ]
Chang, Choong-koo [1 ]
机构
[1] KEPCO Int Nucl Grad Sch KINGS, Dept Nucl Power Plant Engn, Ulsan, South Korea
关键词
Cascading failure; Nuclear power plant; Protection power system; IEC61850; Zone selective interlock; IEC; 61850; INDUSTRIAL;
D O I
10.1016/j.net.2020.06.010
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Cascading failure is the main cause of large blackouts in electrical power systems; this paper analyzes a cascading failure in Hanbit nuclear power plant unit two (2) caused by a circuit breaker (CB) operation failure. This malfunction has been expanded to the loss of offsite power (LOOP). In this study, current practices are reviewed and then the methodologies of how to prevent cascading failures in protection power systems are introduced. An overview on the implementation of IEC61850 GOOSE messaging based zone selective interlocking (ZSI) scheme as key solution is proposed. In consideration of ZSI blocking time, all influencing factors such as circuit breaker opening time, relay I/O response time and messages travelling time in the communication network should be taken into account. The purpose of this paper is to elaborate on the effect of cascading failure in NPP electrical power protection system and propose preventive actions for this failures. Finally, the expected advantages and challenges are elaborated. (c) 2020 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:121 / 130
页数:10
相关论文
共 50 条
  • [21] RADIATION PROTECTION IN RHEINSBERG NUCLEAR POWER PLANT
    GERULLIS, W
    KRUGER, FW
    MICHAELI.UE
    KERNENERGIE, 1970, 13 (07): : 209 - &
  • [22] Cascading failures in electric power systems: What about prices?
    Watts, David
    Ren, Hui
    2007 IREP SYMPOSIUM- BULK POWER SYSTEM DYNAMICS AND CONTROL - VII REVITALIZING OPERATIONAL RELIABLITY, VOLS 1 AND 2, 2007, : 533 - +
  • [23] Subdivision Protection in Electric Power Systems Containing Low-Power Electric Power Plants
    Onisova O.A.
    Onisova, O.A. (onisova@vniir.ru), 1600, Springer Science and Business Media, LLC (48): : 322 - 330
  • [24] A Dynamic Cascading Failure Model Integrating Relay Protection in Power Grid
    Yang, Yujie
    Zhou, Yadong
    Wu, Jiang
    Xu, Zhanbo
    Guan, Xiaohong
    Chen, Wei
    Liu, Ting
    2020 IEEE 16TH INTERNATIONAL CONFERENCE ON AUTOMATION SCIENCE AND ENGINEERING (CASE), 2020, : 1331 - 1336
  • [25] Analysis of cascading failure in electric grid based on power flow entropy
    Bao, Z. J.
    Cao, Y. J.
    Wang, G. Z.
    Ding, L. J.
    PHYSICS LETTERS A, 2009, 373 (34) : 3032 - 3040
  • [26] FIBER OPTICS - USE IN NUCLEAR-POWER PLANT CONTROL AND PROTECTION SYSTEMS
    BRUNO, J
    REID, JB
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (04): : 1319 - 1319
  • [27] Impact of wind power uncertainty on cascading failure in cyber-physical power systems
    Gao, Xingle
    Peng, Minfang
    Tse, Chi K.
    PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2021, 583
  • [28] Korean Standard Nuclear Power Plant response to common mode failure of the digital plant protection system
    Lee, CS
    Park, CE
    Choi, CJ
    Seo, JT
    NUCLEAR TECHNOLOGY, 2002, 139 (01) : 42 - 49
  • [29] NUCLEAR-POWER PLANT FIRE PROTECTION RESEARCH
    CANO, GL
    KLAMERUS, LJ
    BERNARD, EA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1977, 26 : 49 - 50
  • [30] Extreme event loading and cascading failure risk assessment for electric power lines
    Ostendorp, Mark
    Proceedings of the International Conference on Cold Regions Engineering, 1999, : 812 - 823