Comparative studies on radioluminescent and thermoluminescent spectra of LiF:Mg,Cu,P and LiF:Mg,Cu,Si

被引:6
|
作者
Tang, K. [1 ,2 ]
Fan, H. [2 ]
Cui, H. [2 ]
Zhu, H. [2 ]
Liu, Z. [2 ]
机构
[1] State Key Lab NBC Protect Civilian, POB 1044,Ext 201, Beijing 102205, Peoples R China
[2] Solid Dosimetr Detector & Method Lab, POB 1044,Ext 204, Beijing 102205, Peoples R China
关键词
GLOW CURVE STRUCTURE; EMISSION-SPECTRA; LIF-MG; CU; NA; SI PHOSPHOR; SINTERING TEMPERATURES; DOPANTS CONCENTRATIONS; THERMAL-STABILITY; DEPENDENCE; TL; COPPER; DOSIMETER;
D O I
10.1093/rpd/ncv377
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The influence of various annealing treatments on radioluminescent (RL) and thermoluminescent (TL) spectra of LiF:Mg,Cu,Si and LiF:Mg,Cu,P was investigated. The TL and RL emission bands for LiF:Mg,Cu,P are not the same; however, the emission band peaking at similar to 383 nm is predominant in the TL and RL emission for LiF:Mg,Cu,Si. With the increase in annealing temperatures in the range of 240-300A degrees C, for LiF:Mg,Cu,P, the intensity of TL decreases much more rapidly than that of RL. For LiF:Mg,Cu,Si, the area ratios of the two bands of RL and TL remain constant within experimental errors. It suggests that there is a significant decrease in the concentration of recombination centres in LiF:Mg,Cu,P after the annealing, in addition to the decrease in trapping centres, the recombination centres for main TL emission and RL emission in LiF:Mg,Cu,Si are the same, and the recombination centres for TL emission and RL emission in LiF:Mg,Cu,P are not the same. P is a more effective dopant than Si.
引用
收藏
页码:459 / 464
页数:6
相关论文
共 50 条
  • [31] Optical absorption in LiF, LiF:Mg, LiF:Mg,Cu,P irradiated with high gamma and beta doses
    Remy, K.
    Sholom, S.
    Obryk, B.
    McKeever, S. W. S.
    RADIATION MEASUREMENTS, 2017, 106 : 113 - 117
  • [32] INFLUENCE OF THE COOLING RATE ON REPEATABILITY OF LIF-MG,CU,P THERMOLUMINESCENT CHIPS
    PITERS, TM
    BOS, AJJ
    RADIATION PROTECTION DOSIMETRY, 1990, 33 (1-4) : 91 - 94
  • [33] The investigation of LiF:Mg,Cu,P thermoluminescent detectors; The dose response to gamma radiation
    Ramlo, MJ
    Bicron, NE
    Karpov, NA
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D421 - D421
  • [34] Influence of annealing on kinetic trapping parameters in LiF:Mg,Cu,P thermoluminescent phosphors
    Chen, TC
    Stoebe, TG
    RADIATION MEASUREMENTS, 1998, 29 (01) : 39 - 44
  • [35] Preparation, thermoluminescent and electron spin resonance characteristics of LiF:Mg,Cu,P phosphor
    Shinde, SS
    Dhabekar, BS
    Rao, TKG
    Bhatt, BC
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2001, 34 (17) : 2683 - 2689
  • [36] Photon energy response of LiF:Mg,Ti (MTS) and LiF:Mg,Cu,P (MCP) thermoluminescent detectors: Experimental measurements and microdosimetric modeling
    Parisi, Alessio
    Dabin, Jeremie
    Schoonjans, Werner
    Van Hoey, Olivier
    Megret, Patrice
    Vanhavere, Filip
    RADIATION PHYSICS AND CHEMISTRY, 2019, 163 : 67 - 73
  • [37] Recent improvements in LiF:Mg,Ti and LiF:Mg,Cu,P based environmental dosimetry
    Delgado, A
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 129 - 134
  • [38] Comparison of the effects of exposure to light in Harshaw LiF:Mg,Ti and LiF:Mg,Cu,P
    Baker, S. T.
    Gilvin, P. J.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 258 - 260
  • [39] Evaluating two extremity dosemeters based on LiF:Mg,Ti or LiF:Mg,Cu,P
    Luo, LZ
    Velbeck, KJ
    Rotunda, JE
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 211 - 216
  • [40] Evaluating two extremity dosemeters based on LiF:Mg,Ti or LiF:Mg,Cu,P
    Luo, LZ
    Velbeck, KJ
    Rotunda, JE
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A211 - A216