Fracture resistance of single-tooth implant-supported zirconia-based indirect composite-layered molar restorations

被引:25
|
作者
Taguchi, Kohei [1 ]
Komine, Futoshi [2 ]
Fushiki, Ryosuke [2 ]
Blatz, Markus B. [3 ]
Kamio, Shingo [1 ]
Matsumura, Hideo [2 ]
机构
[1] Nihon Univ Grad Sch Dent, Tokyo, Japan
[2] Nihon Univ Sch Dent, Dept Fixed Prosthodont, Tokyo 1018310, Japan
[3] Univ Penn Sch Dent Med, Dept Prevent & Restorat Sci, Philadelphia, PA USA
关键词
dental implant; fracture resistance; implant framework; indirect composite material; zirconia ceramics; PROSPECTIVE CLINICAL-TRIAL; FIXED PARTIAL DENTURES; FREE POLYMER CROWNS; VENEERING MATERIAL; FIBER REINFORCEMENT; COMPLICATION RATES; CERAMIC CROWNS; BITE FORCE; IN-VITRO; STRENGTH;
D O I
10.1111/clr.12199
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the fracture resistance of single-tooth implant-supported zirconia-based indirect composite-layered molar restorations. Material and methods: Forty-four titanium abutments (GingiHue Post) were placed on dental implants (Osseotite Implant). Standardized single-tooth cement-retained implant-supported mandibular molar restorations were fabricated for each of four test groups (n = 11) as follows: porcelain-fused-to-metal crowns (PFM), zirconia-based all-ceramic crowns (ZAC), zirconia-based indirect composite-layered crowns primed with Estenia Opaque Primer for zirconia frameworks (ZIC-E), and zirconia-based indirect composite-layered crowns (ZIC). The crowns were luted with a glass-ionomer cement (Ketac Cem Easymix). F'racture resistance (N) was determined by force application of a perpendicular load to the crowns with a universal testing machine. One-way analysis of variance (ANOVA) and the Tukey's HSD test were used to assess differences in fracture resistance values (alpha = 0.05). Results: Mean fracture resistances (SD) were 3.09 (0.22) kN, 3.11 (0.34) kN, 2.84 (0.21) kN, and 2.50 (0.36) kN for the PFM, ZAC, ZIC-E, and ZIC groups, respectively. Fracture resistance in the ZIC specimens was significantly lower (P < 0.044) than that in the other groups, which did not significantly differ. Conclusions: The fracture resistance of single-tooth implant-supported zirconia-based indirect composite-layered molar crowns primed with Estenia Opaque Primer for zirconia frameworks (ZIC-E) is comparable to that of porcelain-fused-to-metal (PFM) and zirconia-based all-ceramic (ZAC) restorations. Application of Estenia Opaque Primer to zirconia ceramic framework provides superior fracture resistance in implant-supported zirconia-based indirect composite-layered molar crowns.
引用
收藏
页码:983 / 991
页数:9
相关论文
共 50 条
  • [21] Method for developing an optimal emergence profile using heat-polymerized provisional restorations for single-tooth implant-supported restorations
    Macintosh, DCT
    Sutherland, M
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (03): : 289 - 292
  • [22] Veneered Zirconia-Based Restorations Fracture Resistance Analysis
    Al-Wahadni, Ahed
    Shahin, Ahmad
    Kurtz, Kenneth S.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (07): : 651 - 658
  • [23] Metal-free implant-supported single-tooth restorations. Part I: Abutments and cemented crowns
    Edelhoff, Daniel
    Schweiger, Josef
    Prandtner, Otto
    Stimmelmayr, Michael
    Gueth, Jan-Frederik
    QUINTESSENCE INTERNATIONAL, 2019, 50 (03): : 176 - 184
  • [24] Survival and Chipping of Zirconia-Based and Metal-Ceramic Implant-Supported Single Crowns
    Schwarz, Stefanie
    Schroeder, Christin
    Hassel, Alexander
    Boemicke, Wolfgang
    Rammelsberg, Peter
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 : e119 - e125
  • [25] Fracture resistance and survival of implant-supported, zirconia-based hybrid-abutment crowns: Influence of aging and crown structure
    Elshiyab, Shareen H.
    Nawafleh, Noor
    Walsh, Laurence
    George, Roy
    JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2018, 9 (04) : e12355
  • [26] Long-term clinical performance and complications of zirconia-based tooth-and implant-supported fixed prosthodontic restorations: A summary of systematic reviews
    Laumbacher, Harald
    Strasser, Thomas
    Knuettel, Helge
    Rosentritt, Martin
    JOURNAL OF DENTISTRY, 2021, 111 : 103723
  • [27] Clinical outcomes of zirconia-based implant- and tooth-supported single crowns
    Nejatidanesh, Farahnaz
    Moradpoor, Hedayat
    Savabi, Omid
    CLINICAL ORAL INVESTIGATIONS, 2016, 20 (01) : 169 - 178
  • [28] Fracture Resistance and Mode of Failure of Ceramic versus Titanium Implant Abutments and Single Implant-Supported Restorations
    Sghaireen, Mohd G.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (03) : 554 - 561
  • [29] Clinical outcomes of zirconia-based implant- and tooth-supported single crowns
    Farahnaz Nejatidanesh
    Hedayat Moradpoor
    Omid Savabi
    Clinical Oral Investigations, 2016, 20 : 169 - 178
  • [30] Abutment Screw Loosening in Single Implant Restorations: Evaluation of Fracture Strength of Implant-Supported Cement- Retained Monolithic Zirconia Restorations Repaired with Porcelain and Composite Resin
    Asli, Hamid Neshandar
    Falahchai, Mehran
    Rahimabadi, Samiye
    Arbab, Hamidreza
    Mehr, Zoheir Mousavi
    DENTAL HYPOTHESES, 2021, 12 (03): : 128 - 131