Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent

被引:2
|
作者
Geier, Eric T. [1 ]
Theilmann, Rebecca J. [2 ]
Darquenne, Chantal [1 ]
Prisk, G. Kim [1 ]
Sa, Rui Carlos [1 ]
机构
[1] Univ Calif San Diego, Dept Med, Pulm Imaging Lab, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Dept Radiol, Pulm Imaging Lab, San Diego, CA 92103 USA
来源
基金
美国国家航空航天局;
关键词
Medicine; Issue; 148; respiration; lung; specific ventilation; functional magnetic resonance imaging; oxygen enhanced magnetic resonance imaging; ventilation; SUPINE; PERFUSION; QUANTIFICATION; EXERCISE; PRONE; MRI; PET;
D O I
10.3791/59579
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Specific ventilation imaging (SVI) is a functional magnetic resonance imaging technique capable of quantifying specific ventilation - the ratio of the fresh gas entering a lung region divided by the region's end-expiratory volume - in the human lung, using only inhaled oxygen as a contrast agent. Regional quantification of specific ventilation has the potential to help identify areas of pathologic lung function. Oxygen in solution in tissue shortens the tissue's longitudinal relaxation time (T-1), and thus a change in tissue oxygenation can be detected as a change in T-1-weighted signal with an inversion recovery acquired image. Following an abrupt change between two concentrations of inspired oxygen, the rate at which lung tissue within a voxel equilibrates to a new steady-state reflects the rate at which resident gas is being replaced by inhaled gas. This rate is determined by specific ventilation. To elicit this sudden change in oxygenation, subjects alternately breathe 20-breath blocks of air (21% oxygen) and 100% oxygen while in the MRI scanner. A stepwise change in inspired oxygen fraction is achieved through use of a custom three-dimensional (3D)-printed flow bypass system with a manual switch during a short end-expiratory breath hold. To detect the corresponding change in T-1, a global inversion pulse followed by a single shot fast spin echo sequence was used to acquire two-dimensional T-1-weighted images in a 1.5 T MRI scanner, using an eight-element torso coil. Both single slice and multi-slice imaging are possible, with slightly different imaging parameters. Quantification of specific ventilation is achieved by correlating the time-course of signal intensity for each lung voxel with a library of simulated responses to the air/oxygen stimulus. SVI estimations of specific ventilation heterogeneity have been validated against multiple breath washout and proved to accurately determine the heterogeneity of the specific ventilation distribution.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A stable nitroxide radical as a contrast agent for magnetic resonance imaging
    A. A. Savelov
    D. A. Kokorin
    E. Yu. Fursova
    V. I. Ovcharenko
    Doklady Chemistry, 2007, 416 : 241 - 243
  • [42] A cationic gadolinium contrast agent for magnetic resonance imaging of cartilage
    Freedman, Jonathan D.
    Lusic, Hrvoje
    Wiewiorski, Martin
    Farley, Michelle
    Snyder, Brian D.
    Grinstaff, Mark W.
    CHEMICAL COMMUNICATIONS, 2015, 51 (56) : 11166 - 11169
  • [43] Calcium-sensitive magnetic resonance imaging contrast agent
    Li, Wen-hong
    Fraser, Scott E.
    Meade, Thomas J.
    Journal of the American Chemical Society, 1999, 121 (06):
  • [44] Cell Labeling With a Novel Contrast Agent of Magnetic Resonance Imaging
    Oishi, Koichi
    Noguchi, Hirofumi
    Saito, Hiroaki
    Yukawa, Hiroshi
    Miyamoto, Yoshitaka
    Murase, Katsutoshi
    Hayashi, Shuji
    CELL TRANSPLANTATION, 2010, 19 (6-7) : 887 - 892
  • [45] A delayed reaction to the magnetic resonance imaging contrast agent gadobutrol
    Nagai, Hiroshi
    Nishigori, Chikako
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE, 2017, 5 (03): : 850 - 851
  • [46] Hyperpolarized water as an authentic magnetic resonance imaging contrast agent
    McCarney, Evan R.
    Armstrong, Brandon D.
    Lingwood, Mark D.
    Han, Songi
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (06) : 1754 - 1759
  • [47] A calcium-sensitive magnetic resonance imaging contrast agent
    Li, WH
    Fraser, SE
    Meade, TJ
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (06) : 1413 - 1414
  • [48] Quantification of liver capillary permeability using a macromolecular contrast agent for magnetic resonance imaging
    Clement, O
    VuilleminBodaghi, V
    Cuenod, CA
    Siauve, N
    Blustajn, J
    Frija, G
    ACADEMIC RADIOLOGY, 1996, 3 : S342 - S343
  • [49] Magnetic resonance imaging of myocardial perfusion and viability using a blood pool contrast agent
    Dewey, M
    Kaufels, N
    Laule, M
    Schnorr, J
    Raynaud, JS
    Hamm, B
    Taupitz, M
    INVESTIGATIVE RADIOLOGY, 2004, 39 (08) : 498 - 505
  • [50] Quantitative myocardial perfusion magnetic resonance imaging: the impact of pulsatile flow on contrast agent bolus dispersion
    Graafen, Dirk
    Hamer, Julia
    Weber, Stefan
    Schreiber, Laura M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16): : 5167 - 5185