Experimental study on seismic behavior of two-storey modular structure

被引:12
|
作者
Liu, Yang [2 ]
Chen, Zhihua [1 ,2 ]
Liu, Jiadi [2 ]
Zhong, Xu [2 ]
机构
[1] Tianjin Univ, State Key Lab Hydraul Engn Simulat & Safety, 92 Weijin Rd, Tianjin, Peoples R China
[2] Tianjin Univ, Dept Civil Engn, 92 Weijin Rd, Tianjin, Peoples R China
来源
STEEL AND COMPOSITE STRUCTURES | 2020年 / 37卷 / 03期
关键词
modular steel structure; rotary inter-module connection; seismic performance; lateral-force resistance mechanism; deformation pattern; two-storey and full-scale experiment; CONNECTIONS; PLATE; BUILDINGS; DESIGN; JOINT;
D O I
10.12989/scs.2020.37.3.273
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the unique construction method of modular steel buildings (MSBs) with units prefabricated fully off the site and assembled quickly on the site, the inter-module connection for easy operation and overall performance of the system were key issues. However, it was a lack of relevant research on the system-level performance of MSBs. This study investigated the seismic performance of two-storey modular steel structure with a proposed vertical rotary inter-module connection. Three full-scale quasi-static tests, with and without corrugated steel plate and its combination, were carried out to evaluate and compare their seismic behaviour. The hysteretic performance, skeleton curves, ductile performance, stiffness degradation, energy dissipation capacity, and deformation pattern were clarified. The results showed that good ductility and plastic deformation ability of such modular steel structures. Two lateral-force resistance mechanisms with different layout combinations were also discussed in detail. The corrugated steel plate could significantly improve the lateral stiffness and bearing capacity of the modular steel structure. The cooperative working mechanism of modules and inter-module connections was further analyzed. When the lateral stiffness of upper and lower modular structures was close, limited bending moment transfer may be considered for the inter-module connection. While a large lateral stiffness difference existed initially between the upper and lower structures, an obvious gap occurred at the inter-module connection, and this gap may significantly influence the bending moments transferred by the inter-module connections. Meanwhile, several design recommendations of inter-module connections were also given for the application of MSBs.
引用
收藏
页码:273 / 289
页数:17
相关论文
共 50 条
  • [41] Testing robustness: A full-scale experimental test on a two-storey reinforced concrete frame with solid slabs
    Caldentey, Alejandro Perez
    Diego, Yolanda G.
    Fernandez, Freddy Arinez
    Santos, Anastasio P.
    ENGINEERING STRUCTURES, 2021, 240
  • [42] Canopy conductance in a two-storey Siberian boreal larch forest, Russia
    Xue, Bao-Lin
    Li, Zhanling
    Yin, Xin-An
    Zhang, Tieliang
    Iida, Shin'ichi
    Otsuki, Kyoichi
    Ohta, Takeshi
    Guo, Qinghua
    HYDROLOGICAL PROCESSES, 2015, 29 (06) : 1017 - 1026
  • [43] Seismic performance and SSI effects of a two-storey RC school building during the 2014 Cephalonia, Greece, earthquake sequence
    Giarlelis, Christos
    Repapis, Constantinos
    Lamprinou, Evlalia
    Mylonakis, George
    Manolis, George
    Sextos, Anastasios
    BULLETIN OF EARTHQUAKE ENGINEERING, 2023, 21 (09) : 4643 - 4667
  • [44] Experimental seismic damage quantification in a 3-storey laboratory structure
    de Lautoura, Oliver R.
    Omenzetter, Piotr
    DAMAGE ASSESSMENT OF STRUCTURES VII, 2007, 347 : 297 - +
  • [45] Procedure to predict the storey where plastic drift dominates in two-storey building under strong ground motion
    Hibino, Yo
    Ichinose, Toshikatsu
    Costa, J. L. Domingues
    Nielsen, M. P.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2009, 38 (07): : 929 - 939
  • [46] Boundary damage identification of a two-storey framed structure utilising frequency response functions and artificial neural networks
    Centre for Built Infrastructure Research, Faculty of Engineering and Information Technology, University of Technology, Sydney
    NSW
    2007, Australia
    MOVIC - Int. Conf. Motion Vib. Control, Proc., 1600,
  • [47] Damage diagnosis of a two-storey spatial steel braced-frame model
    Xiaodong, Ji
    Jiaru, Qian
    Longhe, Xu
    STRUCTURAL CONTROL & HEALTH MONITORING, 2007, 14 (08): : 1083 - 1100
  • [48] Variation of indoor radon concentrations in two-storey houses in Nowshera District, Pakistan
    Khan, F.
    Wazir, Z.
    Tufail, M.
    Nusrat, M.
    RADIATION PROTECTION DOSIMETRY, 2015, 163 (01) : 133 - 139
  • [49] Thermal comfort investigation on a naturally ventilated two-storey residential house in Malaysia
    Malek, N. A.
    Khairuddin, M. H.
    Rosli, M. F.
    7TH INTERNATIONAL CONFERENCE ON COOLING & HEATING TECHNOLOGIES (ICCHT 2014), 2015, 88
  • [50] Experimental Research on the Shear Performance of the Two-Storey Composite Cold-Formed Thin-Walled Steel Wall
    Yunpeng Chu
    Xiangrong He
    Yong Yao
    Hongjie Hou
    KSCE Journal of Civil Engineering, 2020, 24 : 537 - 550