COMPARISON OF FRACTURE RESISTANCE OF PRESSABLE METAL CERAMIC CUSTOM IMPLANT ABUTMENTS WITH CAD/CAM COMMERCIALLY FABRICATED ZIRCONIA IMPLANT ABUTMENTS

被引:48
|
作者
Kim, Sungtae [1 ,2 ]
Kim, Hyeong-Il [3 ]
Brewer, Jane D. [3 ]
Monaco, Edward A., Jr. [3 ]
机构
[1] Yonsei Univ, Sch Dent Med, Dept Prosthodont, Coll Dent, Seoul 120752, South Korea
[2] SUNY Buffalo, Sch Dent Med, Adv Educ Program Prosthodont, Buffalo, NY 14260 USA
[3] SUNY Buffalo, Sch Dent Med, Dept Restorat Dent, Buffalo, NY 14260 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2009年 / 101卷 / 04期
关键词
WIDTH/LENGTH RATIOS; RESTORATIONS; STRENGTH;
D O I
10.1016/S0022-3913(09)60043-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The adequacy of the strength of dental zirconia abutments under heavy occlusal load condtions is questionable, with degradation of the mechanical properties of zirconia having been reported. Therefore, some alternatives must be considered. Purpose. The purpose of this study was to determine the efficacy of fabricating pressable metal ceramic custom implant (Pr) abutments, and to evaluate the fracture resistance of these abutments. Material and methods. Two groups of implant abutment specimens were fabricated (n=10). The experimental group consisted of Pr abutments, and the control group consisted of CAD/CAM-designed zirconia-based ceramic (Zr) abutments. For the experimental group, custom metal abutments were cast using a compatible metal alloy (Lodestar); this was followed by injection molding with lithium disilicate pressable ceramic (IPS e.max Press) around the metal column of the custom implant abutment. For the control group, 10 specimens were fabricated from CAD/CAM-designed zirconia abutments (Procera Zirconia). Following scanning, all-ceramic crowns with the average dimensions of a human central incisor were fabricated for the experimental and control abutments (n=20) using lithium disilicate pressable ceramic (IPS e.max Press). Each crown was cemented to the implant abutments with a resin luting agent (Variolink 11). The crown-abutment test specimens were fixed to titanium implant analogs and placed in a test stand at 30 degrees from the vertical axis of the specimens in a computer-controlled universal testing device. The independent t test was used to detect if the mean values of the fracture load differed significantly (alpha=.05) between the 2 groups. Results. The mean (SD) fracture load was significantly higher in the Pr group (901.67 (102.05) N) than in the Zr group (480.01 (174.46) N, P<.005). Conclusions. This study found that Pr abutments are stronger than Zr abutments. (J Prosthet Dent 2009;101:226230)
引用
收藏
页码:226 / 230
页数:5
相关论文
共 50 条
  • [21] Retentive force of a conical crown with CAD/CAM-fabricated PEEK and zirconia secondary crowns on titanium implant abutments
    Kamel, Abdullah
    Yamazaki, Toshiki
    Murakami, Natsuko
    Lyu, Huaxin
    Komine, Kohei
    Badr, Amr
    Fekry, Gehan
    Takahashi, Hidekazu
    Wakabayashi, Noriyuki
    DENTAL MATERIALS JOURNAL, 2023, 42 (03) : 336 - 342
  • [22] Comparison of fracture strength and failure mode of different ceramic implant abutments
    Elsayed, Adham
    Wille, Sebastian
    Al-Akhali, Majed
    Kern, Matthias
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04): : 499 - 506
  • [23] CAD/CAM Custom Abutments for Esthetic Anterior Implant-Supported Restoration: Materials and Design
    De Kok I.J.
    Katz L.H.
    Duqum I.S.
    Current Oral Health Reports, 2018, 5 (2) : 121 - 126
  • [24] Wear at the Implant-Abutment Interface of Zirconia Abutments Manufactured by Three CAD/CAM Systems
    Pinheiro Tannure, Ana Luiza
    Cunha, Alfredo Goncalves
    Borges Junior, Luiz Antonio
    da Silva Concilio, Lais Regiane
    Claro Neves, Ana Christina
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (06) : 1241 - 1250
  • [25] In Vitro Fatigue and Fracture Strength Testing of One-Piece Zirconia Implant Abutments and Zirconia Implant Abutments Connected to Titanium Cores
    Stimmelmayr, Michael
    Sagerer, Stefanie
    Erdelt, Kurt
    Beuer, Florian
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 488 - 493
  • [26] Fracture and Fatigue Resistance of Cemented versus Fused CAD-on Veneers over Customized Zirconia Implant Abutments
    Nossair, Shereen Ahmed
    Aboushelib, Moustafa N.
    Morsi, Tarek Salah
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (07): : 543 - 548
  • [27] Fracture load of different crown systems on zirconia implant abutments
    Albrecht, T.
    Kirsten, A.
    Kappert, H. F.
    Fischer, H.
    DENTAL MATERIALS, 2011, 27 (03) : 298 - 303
  • [28] Fatigue fracture resistance of titanium and chairside CAD-CAM zirconia implant abutments supporting zirconia crowns: An in vitro comparative and finite element analysis study
    Giner, Sergio
    Bartolome, Jose F.
    Gomez-Cogolludo, Pablo
    Castellote, Carlos
    Pradies, Guillermo
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 503.e1 - 503.e9
  • [29] Comparing the Fracture Resistance of Alternatively Engineered Zirconia Abutments with Original Equipment Manufactured Abutments with Different Implant Connection Designs
    Jarman, Joseph M.
    Hamalian, Techkouhie
    Randi, Anthony P.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (05) : 992 - 1000
  • [30] CAD/CAM-based Implant Abutments Made of Lithium Disilicate
    Kurbad, A.
    Kurbad, S.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2013, 16 (02) : 125 - 141