Effect of light-curing time on microhardness of a restorative bulk-fill resin composite to lute CAD-CAM resin composite endocrowns

被引:0
|
作者
Daher, Rene [1 ]
Ardu, Stefano [1 ]
Kleverlaan, Cornelis J. [2 ,3 ]
Di Bella, Enrico [4 ]
Feilzer, Albert J. [2 ,3 ]
Krejci, Ivo [1 ]
机构
[1] Univ Geneva, Dept Cariol & Endodontol, 1 Rue Michel Servet, CH-1211 Geneva, Switzerland
[2] Univ Amsterdam, Acad Ctr Dent Amsterdam ACTA, Dept Dent Mat Sci, Amsterdam, Netherlands
[3] Vrije Univ, Amsterdam, Netherlands
[4] Univ Genoa, Dept Econ & Quantitat Methods, Genoa, Italy
来源
AMERICAN JOURNAL OF DENTISTRY | 2020年 / 33卷 / 06期
关键词
BOND STRENGTH; CONVERSION; DEPTH; CURE; POLYMERIZATION; IRRADIANCE; CEMENT; INLAYS;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the minimal irradiation time to reach a sufficient polymerization of a photopolymerizable restorative bulk-fill resin composite to lute endocrowns. Methods: A photopolymerizable restorative bulk-fill resin composite (Filtek One Bulk Fill) was submitted to direct light-curing by a high power LED light-curing unit for 20 seconds as the positive control group (n = 10). Five more test groups (n= 10) were light-cured in a natural tooth mold from three sites (buccal, palatal and occlusal) under a 9.5 mm thick nanohybrid resin composite CAD-CAM endocrown (Lava Ultimate A2 LT), for different irradiation times: 90 seconds per site, 40 seconds per site, 30 seconds per site, 20 seconds per site and 10 seconds per site. Vickers microhardness measurements were made at two different depths and test/control ratios were calculated. Ratios of 0.8 were considered as an adequate level of curing. Results: Analysis shows that 30 seconds x 3 was the minimal irradiation time that presented a test/control ratio above 0.8. Quantile regressions showed that the required irradiation time to reach a test/control ratio of 0.8 at a confidence level of 95% was 38 seconds and 37 seconds for 200 mu m and 500 respectively. There was no statistically significant difference between microhardness of the two depths except for the irradiation time of 10 seconds. A 120-second (40 seconds per buccal, palatal and occlusal site) light-curing of photopolymerizable bulk-fill resin composite to lute a resin composite CAD-CAM endocrown restoration can be considered sufficient to reach adequate polymerization.
引用
收藏
页码:331 / 336
页数:6
相关论文
共 50 条
  • [31] Effect of vibration during bulk and incremental filling on adaptation of a bulk-fill composite resin
    Yung-Soo Kim
    Seung-Ho Baek
    Ryan Jin Young Kim
    Scientific Reports, 12
  • [32] The influence of light-curing time on the bacterial colonization of resin composite surfaces
    Brambilla, Eugenio
    Gagliani, Massimo
    Ionescu, Andrei
    Fadini, Luigi
    Garcia-Godoy, Franklin
    DENTAL MATERIALS, 2009, 25 (09) : 1067 - 1072
  • [33] Bulk-fill resin composites: Polymerization properties and extended light curing
    Zorzin, Jose
    Maier, Eva
    Harre, Sarah
    Fey, Tobias
    Belli, Renan
    Lohbauer, Ulrich
    Petschelt, Anselm
    Taschner, Michael
    DENTAL MATERIALS, 2015, 31 (03) : 293 - 301
  • [34] Is the clinical performance of incremental and bulk-fill resin composite different?
    Tirapelli, Camila
    EVIDENCE-BASED DENTISTRY, 2022, 23 (02) : 84 - 84
  • [35] Influence of Light Curing and Shade on the Microhardness of a Composite Resin
    Firoozmand, Leily Macedo
    Balducci, Ivan
    Maximo de Araujo, Maria Amelia
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2009, 9 (01): : 37 - 42
  • [36] Effect of Light-Curing in the Microhardness of Resin Cements of Dual Polymerization
    Gomes, Isabel
    Lopes, Luis Pires
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2010, 51 (03): : 133 - 138
  • [37] Translucency of CAD-CAM Resin Composite Blocks: A Scoping Review
    Mandurino, Mauro
    Saratti, Carlo Massimo
    Diana, Carlotta
    Sobrero, Andrea
    Gherlone, Enrico Felice
    Cantatore, Giuseppe
    Vichi, Alessandro
    Paolone, Gaetano
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2025,
  • [38] Effect of Thermocycling on Biaxial Flexural Strength of CAD/CAM, Bulk Fill, and Conventional Resin Composite Materials
    Benalcazar Jalkh, E. B.
    Machado, C. M.
    Gianinni, M.
    Beltramini, I
    Piza, M. M. T.
    Coelho, P. G.
    Hirata, R.
    Bonfante, E. A.
    OPERATIVE DENTISTRY, 2019, 44 (05) : E254 - E262
  • [39] Effect of Preheating and Fatiguing on Mechanical Properties of Bulk-fill and Conventional Composite Resin
    Abdulmajeed, A. A.
    Donovan, T. E.
    Cook, R.
    Sulaiman, T. A.
    OPERATIVE DENTISTRY, 2020, 45 (04) : 387 - 395
  • [40] The effect of light-curing modes on the microleakage of cervical resin composite restorations
    Kubo, S
    Yokota, H
    Yokota, H
    Hayashi, Y
    JOURNAL OF DENTISTRY, 2004, 32 (03) : 247 - 254