Interlaboratory inconsistencies in antiphospholipid antibody (aPA) solid phase assays have prompted controversy in clinical laboratory testing for aPA. We found that the aPA ELISA can be influenced by the type of microtiter plate utilized and by the conditions in which the plates are stored. By exposing 96-well, flat-bottom polystyrene microtiter plates to short wave UV light (254 nm), the aPA ELISA signal decreased in a UV dose-dependent manner. No effect was seen with long wave UV light (366 nm). These results were independent of the antibody isotype under study or the phospholipid (PL) antigen used: anionic phosphatidylserine (PS) and cardiolipin (CL), or zwitterionic phosphatidylethanolamine (PE). Purified human beta(2)-glycoprotein I (beta(2)GPI), a known cofactor for anionic PL, and rabbit anti-beta 2GPI antisera were used to demonstrate that beta(2)GPI bound equally to UV treated and untreated microtiter plates. In contrast, recognition of beta(2)GPI on an anionic PL surface was decreased on UV treated plates, suggesting that UV exposure alters the lipid binding properties of the microtiter plate. To determine whether UV exposure inhibited PL binding directly or caused a change in the way the PL was bound, the amount of PL bound to UV treated and untreated plates was measured by using fluorescent labeled PS and a fluorimeter. PS binding was decreased by 53% in UV treated wells as compared to untreated wells. These data show that short wave UV exposure reduces PL binding to polystyrene microtiter plates, thereby reducing the amount of beta(2)GPI bound to PL coated ELISA plates. Thus by using UV exposed microtiter plates, decreased or false-negative aPA ELISA results may be obtained for aPA positive plasmas. (C) 1996 Wiiey-Liss, Inc.
引用
收藏
页码:243 / 249
页数:7
相关论文
共 50 条
  • [31] IMMOBILIZATION OF SCHISTOSOMA-MANSONI ANTIGENS ON POLYSTYRENE MICROTITER TRAYS, FOR USE IN THE ENZYME-LINKED IMMUNOSORBENT-ASSAY (ELISA)
    ROTMANS, JP
    TROPICAL AND GEOGRAPHICAL MEDICINE, 1982, 34 (01): : 103 - 104
  • [32] ULTRASTRUCTURE STUDY ON ALTERATION IN KERATINOCYTES AFTER TMP APPLICATION AND UV EXPOSURE
    TODA, K
    PATHAK, MA
    FITZPATRICK, TB
    ACTA DERMATO-VENEREOLOGICA, 1973, 53 : 35 - 46
  • [33] High-performance microtiter plates for immunosorbent assays made of renewable resources: Polylactic acid biopolymer as a substitute for synthetic polystyrene
    Bouche, FB
    Schecklies, E
    Muller, CP
    CLINICAL CHEMISTRY, 2002, 48 (02) : 378 - 380
  • [34] Study and characterization of UV-irradiated polystyrene microtitre plates for use in an enzyme immunoassay
    Yu, W
    Sun, YK
    Liao, JH
    Zhang, HQ
    Gu, N
    Wu, JG
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2002, 29 (03) : 479 - 482
  • [35] ELISA FOR DETECTION OF ANTI-GLOMERULAR BASEMENT-MEMBRANE ANTIBODIES - INFLUENCE OF VARIOUS MICROTITER-PLATES ON ASSAY-SENSITIVITY
    WEBER, M
    KOHLER, H
    MANNS, M
    ZUMBUSCHENFELDE, KHM
    KIDNEY INTERNATIONAL, 1984, 26 (04) : 529 - 529
  • [36] A NEW ENZYME-LINKED-IMMUNOSORBENT-ASSAY (ELISA) FOR SPERMIDINE USING GLUTARALDEHYDE COUPLING OF THE HAPTEN TO CARRIER-COATED MICROTITER PLATES
    FUJIWARA, K
    KITAGAWA, T
    JOURNAL OF BIOCHEMISTRY, 1993, 114 (05): : 708 - 713
  • [37] Alteration to the Skin Ceramide Profile Following Broad-Spectrum UV Exposure
    Barresi, Rebecca
    Dumbuya, Hawasatu
    Liao, I-Chien
    Chen, Ying
    Yan, Xi
    Wangari-Olivero, Janet
    Baalbaki, Nada
    Lynch, Stephen
    Brieva, Patricia
    Wang, Miao
    Zheng, Qian
    Bouez, Charbel
    JOURNAL OF DRUGS IN DERMATOLOGY, 2022, 21 (01) : 77 - 85
  • [38] Comparison of Nephelometric, UV-Spectroscopic, and HPLC Methods for High-Throughput Determination of Aqueous Drug Solubility in Microtiter Plates
    Hoelke, Bettina
    Gieringer, Sabine
    Arlt, Michael
    Saal, Christoph
    ANALYTICAL CHEMISTRY, 2009, 81 (08) : 3165 - 3172
  • [39] DETECTION OF PLATELET-REACTIVE ANTIBODIES BY A NEW ELISA METHOD BASED ON THE INTERACTION OF BIOTINYLATED PLATELET ANTIGENS WITH STREPTAVIDIN-COATED MICROTITER PLATES
    CORDIANO, I
    STEFFAN, A
    SALVAN, F
    ZUCCATO, P
    GIROLAMI, A
    FABRIS, F
    PATHOLOGIE BIOLOGIE, 1994, 42 (08): : 805 - 806
  • [40] ALCIAN BLUE-TREATED POLYSTYRENE MICROTITRE PLATES FOR USE IN AN ELISA TO MEASURE ANTIBODIES AGAINST SYNTHETIC PEPTIDES
    LAGACE, J
    ARSENAULT, S
    COHEN, EA
    JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 175 (01) : 131 - 135