LC-MS/MS method for the determination of clodronate in human plasma

被引:12
|
作者
Hasan, Mahmoud [1 ,2 ]
Schumacher, Gitta [1 ]
Seekamp, Anne [1 ]
Taedken, Tobias [1 ]
Siegmund, Werner [1 ]
Oswald, Stefan [1 ]
机构
[1] Univ Med, Ctr Drug Absorpt & Transport, Dept Clin Pharmacol, Greifswald, Germany
[2] Future Univ, Dept Pharmaceut Chem, Cairo, Egypt
关键词
Clodronate; Etidronate; LC-MS/MS; Plasma; Quantification; IONIZATION MASS-SPECTROMETRY; DISODIUM CLODRONATE; RENAL-FAILURE; BISPHOSPHONATES; PHARMACOKINETICS; CHROMATOGRAPHY; TOLERABILITY; VALIDATION; URINE;
D O I
10.1016/j.jpba.2014.08.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Clodronate belongs to the class of bisphosphonates which are used for the treatment of bone disorders. Due to its high polarity it has a low and highly variable oral bioavailability which results in low plasma concentrations and requires sensitive bioanalytical methods to characterize its pharmacokinetics in human. Here, we describe for the first time the development and validation of a LC-MS/MS assay for the quantification of clodronate in human plasma. The bisphosphonate was isolated from the biological matrix by protein precipitation using perchloric acid (10%), and derivatized with trimethylorthoacetate prior sample clean-up with liquid-liquid extraction using methyl tert-butyl ether. The chromatography was performed using an isocratic elution with ammonium acetate 5 mM (85% v/v, pH 3.8) and acetonitrile (15% v/v) as mobile phase with a flow rate of 300 mu l/min on a reversed-phase column (Supelco Ascentis (R), C18) temporized at 50 C. The mass spectrometric detection was done using the API4000 triple quadruple mass spectrometer monitoring the mass/charge transitions 301.0/145 for clodronate and 305.2/137.1 for the internal standard etidronate. The analytical range was set to 5-800 ng/ml, allowing an evaluation of the plasma concentration-time profiles of clodronate for approximately 7-8 half-life (similar to 24 h). The method was validated according to current FDA/EMA guidelines on bioanalytical method validation with respect to specificity, linearity, intra- and inter-day accuracy and precision, matrix effect, recovery as well as stability. The precision of the assay was 0.6-6.9% and 0.6-8.1% for the intra-day and inter-day variability, respectively. The intra-day and inter-day accuracy (error) was 0.6-8.8% and 2.2-4.5%. The recovery of the analyte was low (2-3%) but reproducible over the entire validation range and sufficient to monitor the target concentrations in human plasma. The drug was shown to be stable in plasma at room temperature for at least 3 h (96.0 +/- 6%) and for at least 24 h when stored in the cooled autosampler at 4 degrees C (102.4 +/- 4.5%). Clodronate can also undergo up to three freeze-thaw cycles without impaired stability. Thus, the method was shown to possess sufficient specificity, sensitivity, accuracy, precision and stability to measure plasma concentrations of clodronate. Finally, the developed method was successfully applied to study the clodronate serum levels in a pharmacokinetic study in healthy volunteers. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 50 条
  • [11] Determination of Ribavirin in Human Plasma by LC-MS/MS
    Ostervall, J.
    Ostlund, A.
    Pohanka, A.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 725 - 725
  • [12] Determination of lercanidipine in human plasma by LC-MS/MS
    Jang, Moon-Sun
    La, Sookie
    Chang, Kyu Young
    Kang, Seung Woo
    Han, Sang Beom
    Lee, Kyung Ryul
    Lee, Hee Joo
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2008, 21 (01): : 34 - 40
  • [13] Development and validation of a LC-MS/MS method for the determination of viaminate in human plasma
    Yin, Jing
    Ni, Kun-Yi
    Shen, Yue
    Ma, Peng-Cheng
    Cao, Ling
    Wang, Wei-Peng
    Wang, Yu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 376 - 380
  • [14] LC-MS/MS Method Development and Validation for the Determination of Nifedipine in Human Plasma
    Logoyda, Liliya S.
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2020, 10 (05): : 6220 - 6227
  • [15] An LC-MS/MS method for the determination of ofloxacin in 20 μl human plasma
    Meredith, Sandra A.
    Smith, Peter J.
    Norman, Jennifer
    Wiesner, Lubbe
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 58 : 177 - 181
  • [16] A validated LC-MS/MS method for determination of sertaconazole nitrate in human plasma
    Wang, Yuanyuan
    Pang, Lulu
    Wu, Manying
    Ou, Ning
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (31): : 4047 - 4050
  • [17] Direct injection LC-MS/MS method for the determination of teicoplanin in human plasma
    Kim, Kwang-Youl
    Cho, Sang-Heon
    Song, Yong-Hyun
    Nam, Moon-Suk
    Kim, Cheol-Woo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1008 : 125 - 131
  • [18] Validation of a selective method for determination of paroxetine in human plasma by LC-MS/MS
    Massaroti, P
    Cassiano, NM
    Duarte, LF
    Campos, DR
    Marchioretto, MAM
    Bernasconi, G
    Calafatti, S
    Barros, FAP
    Meurer, EC
    Pedrazzoli, J
    JOURNAL OF PHARMACY AND PHARMACEUTICAL SCIENCES, 2005, 8 (02): : 340 - 347
  • [19] A New and Sensitive LC-MS/MS Method for the Determination of Clopidogrel in Human Plasma
    Bibire, Nela
    Vieriu, Madalina
    Tantaru, Gladiola
    Apostu, Mihai
    Agoroaei, Luminita
    Panainte, Alina Diana
    Znagovan, Alexandru
    Vlase, Aurel
    REVISTA DE CHIMIE, 2014, 65 (07): : 807 - 810
  • [20] Protein Precipitation Method for Determination of Zileuton in Human Plasma by LC-MS/MS
    Yeghig Armoudjian
    Astghik Mikayelyan
    Hasmik Zakaryan
    Armine Aleksanyan
    Harutyun Alaverdyan
    Journal of Pharmaceutical Innovation, 2020, 15 : 581 - 590