Double-plate calibration for coil capacitance effect and application in high-frequency eddy-current testing

被引:3
|
作者
Xu, Jin [1 ]
Lei, Yinzhao [1 ]
机构
[1] Beihang Univ, Sch Automat Sci & Elect Engn, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
capacitance effect; double-plate calibration; thickness measurement; conductivity measurement; high-frequency eddy-current testing;
D O I
10.1088/1361-6501/abc9f9
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In high-frequency eddy-current testing, the coil impedance is often seriously affected by the capacitance effect, while the existing calibration method only corrects the capacitive couplings within the coil itself and ignores the coupling between the coil and the conductor. Combined with the equivalent circuit, a correction method for both the capacitive couplings is proposed using single-plate calibration. Furthermore, considering the skin effect at high frequencies, which leads to the calculation error of coil impedance, a modified impedance is introduced in the equivalent circuit and the double-plate calibration is presented. Using the two proposed methods and the existing calibration method, the experimental values of the coil impedance were respectively corrected when the coil was on a single-coated plate (titanium coating and TiAl6V4 titanium alloy substrate), and compared with the theoretical values between 1 and 100 MHz. The results show a sequentially improved correction effect of the existing calibration method, single-plate calibration, and double-plate calibration. Combined with the Levenberg-Marquardt method, the double-plate calibration was applied to the parameter measurement of the conductive plate with tens of micrometer coating. Through analyzing the sensitivity function of each tested parameter, we employed the inductance to calculate the substrate conductivity at hundreds of kilohertz and the resistance to calculate the coating thickness and conductivity at tens of megahertz. The parameters of three single-coated plates with coating thicknesses of 23 mu m, 32 mu m and 52 mu m were respectively tested, and the results show that the relative measurement errors of all parameters are less than 15%.
引用
收藏
页数:9
相关论文
共 40 条
  • [21] Thickness Measurement of an Iron Plate Using Low-Frequency Eddy Current Testing With an HTS Coil
    Sasayama, Teruyoshi
    Ishida, Tomoki
    Matsuo, Masaaki
    Enpuku, Keiji
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (05)
  • [22] Analytical modelling and simulations for high-frequency eddy current testing with planar spiral coils
    Cao, Binghua
    Li, Xiaohan
    Wang, Mengyun
    Fan, Mengbao
    NONDESTRUCTIVE TESTING AND EVALUATION, 2021, 36 (02) : 195 - 208
  • [23] Physics-Guided Deep Learning for Plate Permeability Estimation With Single to Multiple Frequency Transformation of Eddy-Current Testing
    Xia, Zihan
    Meng, Tian
    Huang, Ruochen
    Fletcher, Adam
    Shao, Yuchun
    Lu, Mingyang
    Peyton, Anthony
    Yin, Wuliang
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2024, 20 (04) : 6109 - 6118
  • [24] Lift-off effect in high-frequency eddy current conductivity spectroscopy
    Abu-Nabah, Bassam A.
    Nagy, Peter B.
    NDT & E INTERNATIONAL, 2007, 40 (08) : 555 - 565
  • [26] Differential Coupling Double-Layer Coil for Eddy Current Testing With High Lift-Off
    Chen, Kefan
    Gao, Bin
    Tian, Gui Yun
    Yang, Yupei
    Yang, Changrong
    Ma, Qiuping
    IEEE SENSORS JOURNAL, 2021, 21 (16) : 18146 - 18155
  • [27] A high-frequency eddy current inspection system and its application to the residual stress characterization
    Nakagawa, N
    Lee, C
    Shen, Y
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 25A AND 25B, 2006, 820 : 1418 - 1425
  • [29] Research on Mechanical Design with Design and Implement of High-Frequency Excitation Signal Source in Eddy Current Testing
    Zeng, Wei Qin
    Zhang, Wei Min
    Wang, Shu Hao
    ADVANCED RESEARCH ON MECHANICAL ENGINEERING, INDUSTRY AND MANUFACTURING ENGINEERING III, 2013, 345 : 128 - +
  • [30] A HIGH FREQUENCY EDDY-CURRENT, NON-DESTRUCTIVE TESTING APPARATUS WITH AUTOMATIC PROBE POSITIONING SUITABLE FOR SCANNING APPLICATIONS
    OWSTON, CN
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1970, 3 (10): : 814 - &