Double-plate calibration for coil capacitance effect and application in high-frequency eddy-current testing

被引:3
|
作者
Xu, Jin [1 ]
Lei, Yinzhao [1 ]
机构
[1] Beihang Univ, Sch Automat Sci & Elect Engn, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
capacitance effect; double-plate calibration; thickness measurement; conductivity measurement; high-frequency eddy-current testing;
D O I
10.1088/1361-6501/abc9f9
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In high-frequency eddy-current testing, the coil impedance is often seriously affected by the capacitance effect, while the existing calibration method only corrects the capacitive couplings within the coil itself and ignores the coupling between the coil and the conductor. Combined with the equivalent circuit, a correction method for both the capacitive couplings is proposed using single-plate calibration. Furthermore, considering the skin effect at high frequencies, which leads to the calculation error of coil impedance, a modified impedance is introduced in the equivalent circuit and the double-plate calibration is presented. Using the two proposed methods and the existing calibration method, the experimental values of the coil impedance were respectively corrected when the coil was on a single-coated plate (titanium coating and TiAl6V4 titanium alloy substrate), and compared with the theoretical values between 1 and 100 MHz. The results show a sequentially improved correction effect of the existing calibration method, single-plate calibration, and double-plate calibration. Combined with the Levenberg-Marquardt method, the double-plate calibration was applied to the parameter measurement of the conductive plate with tens of micrometer coating. Through analyzing the sensitivity function of each tested parameter, we employed the inductance to calculate the substrate conductivity at hundreds of kilohertz and the resistance to calculate the coating thickness and conductivity at tens of megahertz. The parameters of three single-coated plates with coating thicknesses of 23 mu m, 32 mu m and 52 mu m were respectively tested, and the results show that the relative measurement errors of all parameters are less than 15%.
引用
收藏
页数:9
相关论文
共 40 条
  • [1] SIGNAL OF EDDY-CURRENT TRANSDUCER SITUATED ABOVE A NONMAGNETIC PLATE AND SUPPLIED WITH HIGH-FREQUENCY PULSES
    DYAKIN, VV
    SANDOVSKII, VA
    DUDAREV, MS
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1990, 26 (05): : 349 - 353
  • [2] HIGH-FREQUENCY EDDY-CURRENT INSPECTION OF LOW CONDUCTIVITY MATERIALS
    GEHLEN, M
    MATERIALS EVALUATION, 1983, 41 (02) : A5 - A5
  • [3] APPROXIMATE BOUNDARY ELEMENT FORMULATION FOR HIGH-FREQUENCY EDDY-CURRENT PROBLEM
    ENOKIZONO, M
    TODAKA, T
    IEEE TRANSACTIONS ON MAGNETICS, 1993, 29 (02) : 1504 - 1507
  • [4] DIVISION OF MEASURING CHANNELS IN HIGH-FREQUENCY EDDY-CURRENT FLAW DETECTORS
    KHANDETSKII, VS
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1989, 25 (06): : 419 - 424
  • [5] A Numerical Simulation Method for High-Frequency Eddy Current Testing Considering Displacement Current Effect
    Guo, Wei
    Xie, Shejuan
    Du, Yali
    Chen, Hong-En
    Chen, Zhenmao
    Takagi, Takayuki
    Uchimoto, Tetsuya
    IEEE TRANSACTIONS ON MAGNETICS, 2024, 60 (03) : 1 - 4
  • [6] High-Frequency Modeling of Metal Fill Eddy-Current Loss in Integrated Circuits
    Gaskill, Steven G.
    Shilimkar, Vikas S.
    Weisshaar, Andreas
    2013 EUROPEAN MICROWAVE CONFERENCE (EUMC), 2013, : 975 - 978
  • [7] High-frequency eddy-current effects in low-profile transformer windings
    Dai, N
    Lee, FC
    PESC'97: 28TH ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE - RECORD, VOLS I AND II, 1997, : 641 - 647
  • [8] COMPUTATION OF HIGH-FREQUENCY TM EDDY-CURRENT LOSSES IN MAGNETIC-MATERIALS
    FAWZI, TH
    AHMED, MT
    BURKE, PE
    JOURNAL OF APPLIED PHYSICS, 1985, 57 (08) : 3863 - 3865
  • [9] EDDY-CURRENT MONITORING WITH A PULSED HIGH-FREQUENCY CARRIER ELECTROMAGNETIC FIELD.
    Sandovskii, V.A.
    Dyakin, V.V.
    Dudarev, M.S.
    The Soviet journal of nondestructive testing, 1986, 22 (05): : 324 - 331
  • [10] Measuring and Imaging Permittivity of Insulators Using High-Frequency Eddy-Current Devices
    Gaebler, Simone
    Heuer, Henning
    Heinrich, Gert
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (08) : 2227 - 2238