Study on Voltage Response Method of Transformer Condition Assessment

被引:0
|
作者
Zhang Tao [1 ]
Cai Jin-ding [1 ]
机构
[1] Fuzhou Univ, Coll Elect Engn & Automat, Fuzhou, Peoples R China
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Accurate condition assessment of power transformer is needed to guarantee transformer operation safely and reliably. In this paper the technique and application of return voltage measurement and some results of dielectric response measurements of several transformers was introduced. Voltage response measurements were performed on various transformers with different voltage grades, various operating periods, different moisture contents and aging degrees on site. Derived moisture contents from return voltage measurement were compared with the corresponding moisture contents obtained from the analysis of oil samples. Based on on-site experiments and theoretical analysis, the criteria for insulation state of transformer are proposed. Moisture condition of transformer insulation can be determined by using return dominant time constant, and a good correlation between aging degree and the return voltage initial slopes of the aged transformers. Field test performed on several transformers, its interpretation of results are also presented, which proves that RVM measurements can be used as a reliable tool for evaluating moisture content in transformer insulation.
引用
收藏
页码:580 / 583
页数:4
相关论文
共 50 条
  • [21] A power transformer insulation condition assessment method based on set pair analysis
    Liao, Ruijin
    Zheng, Hanbo
    Yang, Lijun
    Zhang, Yiyi
    Huang, Feilong
    Sun, Caixin
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (21): : 55 - 60
  • [22] Power Transformer Mechanical Condition Assessment with a Vibration-based Diagnostic Method
    Zizins-Malisevs, Sergejs
    Poiss, Gints
    2015 56TH INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON), 2015,
  • [24] Finite Element Method Modeled Dielectric Response for Condition Evaluation of Transformer Insulation
    Cui, Yi
    Ekanayake, Chandima
    Saha, Tapan K.
    Du, Peidong
    Ma, Hui
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 39 - 42
  • [25] The Transformer Condition Estimation Method Research
    Dong, Junyu
    Wei, Jie
    Yu, Hong
    Cui, Zhigang
    Chen, Yongqin
    Chen, Xin
    Lan, Ma
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ELECTROMECHANICAL CONTROL TECHNOLOGY AND TRANSPORTATION, 2015, 41 : 152 - 157
  • [26] Analysis of Dielectric Response Measurements for Condition Assessment of Oil-Paper Transformer Insulation
    Koch, Maik
    Prevost, Thomas
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) : 1908 - 1915
  • [27] Investigation of an expert system for the condition assessment of transformer insulation based on dielectric response measurements
    Saha, TK
    Purkait, P
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (03) : 1127 - 1134
  • [28] Study on response characteristic of voltage sensor mounted at the tap of transformer bushing
    Sima, Wen-Xia
    Lan, Hai-Tao
    Du, Lin
    Sun, Cai-Xin
    Yao, Chen-Guo
    Yang, Qing
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2006, 26 (21): : 172 - 176
  • [29] Study on Power Transformer Fault Risk Assessment Method
    Cao, Yongxing
    Shen, Xing
    Peng, Qian
    Liu, Fan
    Yan, XiaoHu
    Zhang, Hailong
    ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING II, PTS 1-3, 2013, 433-435 : 691 - +
  • [30] Transient Response Study on Transformer Windings Under Impulse Voltage Stresses
    Masdi, Hendri
    Mariun, Norman
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (03): : 1022 - 1026